My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
815 SIEVERS-DUECY BLVD 2025-05-05
>
Address Records
>
SIEVERS-DUECY BLVD
>
815
>
815 SIEVERS-DUECY BLVD 2025-05-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/5/2025 7:46:45 AM
Creation date
11/19/2024 11:57:43 AM
Metadata
Fields
Template:
Address Document
Street Name
SIEVERS-DUECY BLVD
Street Number
815
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
960
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• `Seismic Bracing <br /> i <br /> TOLCOT" Fig. 1001 - Sway Brace Attachment (UL Listed) <br /> Size Range: Pipe size to be braced: 1"i25mm)thru 8"(200mm) IPS. OPM c el us <br /> Pipe size used for bracing: 1"(25mm)and 11/4'(32mm) Schedule 40 IPS. <br /> to <br /> Material: Steel LISTED <br /> ' Function: For bracing pipe against sway and seismic disturbance. <br /> a, The pipe attachment component of a sway brace system: <br /> w Fig. 1001 is used in conjunction with a Fig. 900 Series fitting and <br /> ;' joined together with bracing pipe per NFPA 13,forming a complete <br /> to sway brace assembly. <br /> Features: Can be used to brace schedule 7 through schedule 40 IPS. <br /> Field adjustable, making critical pre-engineering of bracing pipe n-setioits <br /> length unnecessary. Unique design requires no threading of bracingpipe. Comes assembled and ready for installation. Fg. 1001 has built-invisual verification of correct installation. See installation note below. <br /> Installation Note: Position Fig. 1001 over the pipe to be braced and tightentwo hex head cone point set bolts until heads bottom <br /> out.A minimum of 1'(25mm) pipe extension is recommended. Brace pipe <br /> can be installed on top or bottom of pipe to be braced. <br /> Approvals: Underwriters Laboratories Listed in the USA(UL) <br /> and Canada(cUL). Included in our Seismic Engineering Guidelines approved <br /> by the State of California Office of Statewide Health Planning and <br /> Development(OSHPD). For additional load, spacing and placement <br /> information relating to OSHPD projects, please refer to our Seismic <br /> Engineering Guidelines, OPM-0052-13. m <br /> For FM Approval information refer to FM Approved page 67. s14. <br /> AP- <br /> Finish: Plain or Electro-Galvanized. Contact customer service for alternative ' <br /> finishes and materials. <br /> Order By: Order by figure number, pipe size to be braced,followed by pipe -,- <br /> size used for bracing (1'(25mm)or 11/4"(32mm)), and finish. <br /> Important Note: Fig. 1001 is precision manufactured to perform its <br /> function as a critical component of a complete bracing assembly.To ensure <br /> performance,the UL Listing requires that Fig. 1001 must be used only with <br /> other TOLCO bracing products. <br /> Pipe 3 Part Number&Approx.Wt./100 Design Load-Lbs. <br /> Size 1"(24mm)Brace Pipe 11/4"(32mm)Brace Pipe For Brace Pipe Size 1"/11/4" <br /> Sch.7 Sch.10 Sch.40 <br /> in. (mm) Lbs. (kg) 1 Lbs. (kg) 1"/11/4" 1"/11/4" 1"/11/4" <br /> 1" (25) 1001-1 X 1 100.0 (45.3) 1001-1 X 11/4 118.0 (53.5) --/-- 1000/1000 1000/1000 <br /> 11/4"(32) 1001-11/4 X 1 100.0 145.3) 1001-11/4 X 11/4 114.0 (51.7) 1 1000/1000 1000/1000 1000/1000 <br /> 172"140) 1001-11/2 X 1 100.0 (45.3) 1001-11/2 X 11/4 115.0 (52.1) ! 1000/1000 1500 11500 1500/1500 <br /> 2" (50) 1001-2 X 1 108.0 (49.0) 1001-2 X 11/4 121.0 (54.81 1000/1000 2015/2015 2015/2015 <br /> t <br /> 21/2"(65) 1001-21/2 X 1 138.6 (62.8) 1001-21/2 X 11/4 160.4 (72.7) 1 1600/1600 2015/2765 2015/2765 <br /> 3" (80) 1001-3 X 1 147.2 (66.7) 1001-3 X 11/4 168.7 (76,5) 1600/1600 2015/2765 2015/2765 <br /> 4" (100) 1001-4 X 1 160.9 (73.0) 1001-4 X 11/4 182.4 (82.7) 1600/1600 2015/2765 2015/2765 <br /> 6" (150) 1001-6 X 1 190.0 186.2) 1001-6 X 11/4 211.4 (95.9) 1600/1600 2015/2765 2015/2765 <br /> 8" (200) 1001-8 X 1 217.4 (98.6) 1001-8 X 11/4 238.8 (108.3) 1600/1600 2015/2765 2015/2765 <br /> Note: Metric sizes are available, contact factory. <br /> \,' ,/,,;-1------; \ I\I ( I\) <br /> I. <br /> j j O ) <br /> . Fig,1001 <br /> All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. <br /> Eaton 66 B-Line series Fire Protection Solutions <br />
The URL can be used to link to this page
Your browser does not support the video tag.