Laserfiche WebLink
2 3 4 5 6 <br /> DESIGNDYKEMAN <br /> ARCHITECTURE + <br /> MOUNT TO SIP PANEL ROOF <br /> ACCORDING TO SIP <br /> MANUFACTURER'S <br /> INSTRUCTIONS <br /> E SIDING� — E <br /> MECH PLENUM,SEE PLANSCONSULTANT: <br /> OUTDOOR CONDENSOR UNIT <br /> L ROOF,jEEARCH FOR DETAILS <br /> INSULATE CA PLENUMS <br /> TO MEET WSEC <br /> REQUIREMENTS /NEOPRENE VIBRATION <br /> CONCRETE WALL PER ARCH / ISOLATORS,SIZED FOR <br /> TOTAL STATIC DE E C O T O P E <br /> DEFLECTION <br /> 1/2"THREADED ROD,TYPICAL <br /> SEAL ALL AROUND <br /> REFRIGERANT LINES <br /> MOUNT PER MANUFACTURERS TO INDOOR UNIT - <br /> HVAC UNIT <br /> SPECIFICATION.INCLUDE DRAIN PAN <br /> AND ROUTE CONDENSATE TO <br /> APPROVED LOCATION <br /> FIXED LOUVER WITH <br /> MOUNT UNITS HIGH ON WALL TO • <br /> ALUMINUM INSECT ALLOW CAR PARKING BELOW(MIN ROUTE CONDENSATE <br /> SCREEN <br /> ABOVE GARAGE FINISHED FLOOR) LINE M,OORP0 <br /> TO INDIRECT DRAIN R LOCK NUT,TYPICAL pF wASyN0 <br /> APPROVED LOCATION OG� <br /> FLASHING i <br /> NOTES: 2 <br /> � 55029 ��v <br /> WALL 1. EQUIPMENT MOUNTING AND CONNECTION AND SEISMIC RESTRAINTS °.�fSReclslca�°���? <br /> NOTE: TO BE DESIGNED AND STAMPED BY LICENSED WASHINGTON STATE 9/ONALE <br /> 1. EQUIPMENT SUPPORT AND CONNECTION TO BE DESIGNED AND ENGINEER AS A DEFERRED SUBMITTAL <br /> STAMPED BY A LICENSED WASHINGTON STATE ENGINEER SUBMITTED <br /> D AS A DEFERRED SUBMITTAL ••• • • D <br /> n LOUVER PLENUM Y WALL HUNG OUTDOOR UNIT DETAIL n VIBRATION ISOLATION <br /> 12"=1'-0" 12"=1'-0" 12"=1'-0" <br /> TENANT <br /> IMPROVEMENTS <br /> FOR <br /> �D"I-STRUT HOPEWORKS <br /> /\ 12" 20 GAUGE SHEET METAL MOUNT UNIT TO WALL WITH <br /> 12" MIN�/ HOOD WITH 1-1/2"DUCT MANUFACTURER'S BRACKET, <br /> ALL <br /> MIN LINER INSIDE CLAMP PIPING AND ELECTRICAL <br /> SHEET METAL OR FLEX-TUBE CONNECTIONS SHALL BE MADE AT <br /> COLLAR SEALED WATERTIGHT BEHIND THE UNIT IN THE <br /> O INTERIOR WALL.UNIT SHALL SIT <br /> DUCT SIZE 2" FLUSH ON THE WALL 3315 BROADWAY <br /> EVERETT, WA <br /> CRUSH REFRIGERAN BID SET <br /> 8" RESISTANT T <br /> MIN O INSULATION PIPING <br /> L 08/29/2022 <br /> ROOFING BY CONTRACTOR INTERIOR FRAMED WALL <br /> WALL HUNG INDOOR UNIT This drawing is: <br /> C REFRIGERAN 1.Copyrighl2017 Dykem an,Inc. 0 <br /> SECURE WITH R10 T 2.The Architect's Instrument of Professional Service. <br /> SCREWS CLAMP PIPING 3.For use on this project only.Obtain Architect's <br /> (2 PER SIDE) INSULATION written permission for any other use or reproduction. <br /> INDOOR UNIT DISCONNECT <br /> UNI-STRUT SHALL BE RECESSED IN WALL, PROJECT <br /> SUBMIT DISCONNECT TO <br /> DUCT SIZE AS INDICATED ON PLANS NOTES: ECOTOPE FOR REVIEW <br /> 20121-031 <br /> 1. USE ZSI CUSH-A-THERM INSULATED PIPING CLAMP OR EQUIVALENT <br /> NOTE: <br /> 1. REFER TO ARCHITECTURAL PLANS FOR ROOF CONSTRUCTION. 2. EQUIPMENT MOUNTING AND CONNECTION TO BE DESIGNED AND STAMPED BY • <br /> 2. ALL EDGES SHALL BE ROLLED AND TURNED DOWN,SHARP EDGES WILL NOT BE ACCEPTED. LICENSED WASHINGTON STATE ENGINEER AS A DEFERRED SUBMITTAL.INSTALL NOTES: MARK DATE DESCRIPTION <br /> 3. SEAL AS REQUIRED TO MAKE ALL JOINTS AND PENETRATIONS WATERTIGHT. SEISMIC RESTRAINTS IF REQUIRED 1. PROVIDE WITH CONDENSATE PUMP IF NECESSARY. <br /> n ROOF PENETRATION DETAIL n PIPE HANGER INSULATION n TYPICAL WALL HUNG UNIT DETAIL <br /> 8 12,E_ _� 5 12"_�'_o" 2 12"_ _O„ <br /> SEAL AROUND ALL <br /> OPENINGS WITH <br /> SILICONE SEALANT. <br /> COLOR TO MATCH <br /> B 2 BUILDING B <br /> SECURE • <br /> REFRIGERANT PIPING <br /> TO SUPPORTS WITH PRINCIPAL IN CHARGE:I <br /> 16 GAUGE <br /> MECHANICAL PIPE PROJECT MANAGER: <br /> CLAMP OR EQUAL GALVANIZED PROJECT ARCHITECT: I <br /> SLEEVE <br /> RUN INSULATION OF JOB CAPTAIN: <br /> SUCTION LINE THRU <br /> CLAMP ABBE M BLY r REFRIGERANT TUBING <br /> 0 <br /> 3 MECHANICAL STEEL INSULATION <br /> CHANNEL OR EQUAL <br /> 0 4 1. CLEVIS TYPE PIPE HANGER WELD BOTH SIDES(TYPICAL) 4 <br /> 2. THREADED ROD CUT TO LENGTH WALL <br /> 5 3. SHIELD FOR INSULATION-LENGTH <br /> 1.5 TIMES INSULATION DIAMETER A xNCHH xOREEDD 114"ANGLE <br /> ANCHORED TO STRUCTURE <br /> 4. INSULATION WITH TWO 3/8"x 3" <br /> EXPANSION BOLTS OR TWO <br /> 5. CARRIER PIPE LARGE LAG BOLTS DRAWING <br /> NOTES: <br /> 1. REFER TO PLANS FOR SIZES AND CONTINUATION <br /> A MECHANICAL - A <br /> PIPE HANGER-CLEVIS TYPE REFRIGERANT PIPE WALL SUPPORT <br /> 12"=1'-0" 12"=1'-0" DETAILS <br /> DRAWING <br /> a <br /> 2 3 4 5 6 <br />