My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1223 LOMBARD AVE 2025-01-24
>
Address Records
>
LOMBARD AVE
>
1223
>
1223 LOMBARD AVE 2025-01-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/24/2025 9:34:02 AM
Creation date
11/21/2024 9:05:20 AM
Metadata
Fields
Template:
Address Document
Street Name
LOMBARD AVE
Street Number
1223
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Table 406a2 <br /> Energy Credits (2015 Code) <br /> OPTION DESCRIPTION CREDITS) Estimated Cost <br /> la EFFICIENT BUILDING ENVELOPE I a: 0.5 <br /> Prescriptive compliance is based on Table R402.1.1 with the following modifications: <br /> Vertical fenestration U =0.28 <br /> FloorR-38 <br /> Slab on grade R-10 perimeter and under entire slab <br /> Below grade slab R-10 perimeter and under entire slab <br /> or <br /> Compliance based on Section R402.1.4: Reduce the Total UA by 5%. <br /> lb EFFICIENT BUILDING ENVELOPE lb: 1.0 <br /> Prescriptive compliance is based on Table R402.1.1 with the following modifications: <br /> Vertical fenestration U =0.25 <br /> Wall R-21 plus R-4 <br /> Floor R-38 <br /> Basement wall R-21 int plus R-5 ci <br /> Slab on grade R-10 perimeter and under entire slab <br /> Below grade slab R-I0 perimeter and under entire slab <br /> • <br /> or <br /> Compliance based on Section R402.1.4: Reduce the Total UA by 15%. <br /> 1 c EFFICIENT BUILDING ENVELOPE 1 c: 2.0 <br /> Prescriptive compliance is based on Table R402.1.1 with the following modifications: <br /> Vertical fenestration U =0.22 <br /> Ceiling and single-rafter or joist-vaulted R-49 advanced <br /> Wood frame wall R-21 int plus R-12 ci <br /> • <br /> Floor R-38 <br /> Basement wall R 21 int plus R-12 ci <br /> Slab on grade R-10 perimeter and under entire slab <br /> Below grade slab R-10 perimeter and under entire slab <br /> or <br /> Compliance based on Section R402.1.4: Reduce the Total UA by 30%. <br /> 1 d' EFFICIENT BUILDING ENVELOPE Id: 0.5 <br /> Prescriptive compliance is based on Table R402.1.1 with the following modifications: <br /> Vertical fenestration U=0.24 <br /> 2a AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION 2a: 0.5 <br /> Compliance based on R402.4.12: Reduce the tested air leakage to 3.0 air changes per <br /> hour maximum <br /> and <br /> All whole house ventilation requirements as determined by Section M1507.3 of the • <br /> International Residential Code shall be met with a high efficiency fan(maximum 0.35 <br /> watts/cfm),not interlocked with the furnace fan_Ventilation systems using a furnace <br /> including an ECM motor are allowed,provided that they are controlled to operate at <br /> low speed in ventilation only mode. <br /> To qualify to claim this credit,the building permit drawings shall specify the option <br /> being selected and shall specify the maximum tested building air leakage and shall <br /> show the qualifying ventilation system_ <br /> 2b AIR LEAKAGE CONTROL AND EFt'1CIENT VENTILATION 2b: 1.0 <br /> Compliance based on Section R402.4_1 2:-Reduce the tested air leakage to 2.0 air <br /> changes per hour maximum and <br /> All whole house ventilation requirements as determined by Section M15073 of the <br /> International Residential Code shall be met with a heat recovery ventilation system <br /> with minimum sensible heat recovery efficiency of0.70_ <br /> To qualify to claim this credit,the building permit drawings shall specify the option <br /> being selected and shall specify the Maximum tested building air leakage and shall <br /> show the heat recovery ventilation system. . <br />
The URL can be used to link to this page
Your browser does not support the video tag.