Laserfiche WebLink
r'Err <br /> CITYOF EVERETT <br /> Public Works Department <br /> January 22, 2019 <br /> Owner: Wilkinson <br /> Job Address:1511 Oakes Ave, Plan Check No: C1810-003 <br /> RE: Building Permit Review Letter <br /> Dear Mr. Vital, Laurente Vital. plans@arnencanhorneplanners corn (425) 258-6400 <br /> In response to the application for a building permit, the plans have been examined and you are advised <br /> that revisions may be necessary before a permit can be issued. Please review and respond to the <br /> comments below. <br /> All items in the previous correction letter (listed below) are required to be <br /> addressed prior to a building permit being issued. <br /> All items in the previous correction letter was already address in the previous resubmital. <br /> If another correction cycle is needed, Please omit items already addressed. <br /> The structure in its current condition is subject to condemnation if the corrections <br /> listed below are not addressed. <br /> I . City of Everett and Snohomish County records show a 1-bedroom house with an <br /> unfinished basement and garage. The plans you have submitted show an existing three- <br /> bedroom house with no garage. There are no records of permits for the modifications that <br /> have been done to this structure. City of Everett and Snohomish County records shows <br /> a 1-bedroom and an unfinished basement The plan is revised to reflect the city and county <br /> records <br /> 2. Submit new drawings reflecting the conversion of the basement into living space from a <br /> garage, finishing the unfinished basement, removal of the posts supporting the first floor <br /> framing at the basement and alterations to the layout of the main floor including the relocation <br /> of the kitchen, removal of interior partitions, removal of stairs to upper floor and vaulting the <br /> ceiling (if applicable). All modifications shall comply with the current codes,including 2015 <br /> International Residential Code,2015 Washington State Energy Code,2015 Uniform Plumbing <br /> ode,2015 International Mechanical Code,2014 National Electrical Code and the 2015 <br /> international Fire Code. Unfinished basement to become living space Existing post, beams <br /> and 1st floor framing to remain New interior partition and new furring wall as shown on the <br /> basement plan Existing kitchen at 1st floor to remain Portion of existing structure/stairs to <br /> remove as shown to accommodate new addition <br /> 3. Provide"Building Section" drawings specific to this structure. Sections shall be cut through both <br /> North/South and EastNVest directions, showing the new construction and the existing structure. <br /> Building sections provided See Sheet 3 <br /> 4. Provide ledger detail to show how new floor joists are attached to the existing exterior wall <br /> See sheet 3. building section A 1/� <br />