Laserfiche WebLink
5. Provide detail(s) at existing roof line show how new roof structures supported at existing walls. <br /> See sheet 3. building section A. <br /> 6. Provide roof framing plan showing all trusses and over framing size,species and grade. <br /> See Sheet 2, Sheet 3 and Sheet 4 <br /> 7. The plans appear to show a vaulted ceiling in the existing dining room. Provide section and/or <br /> details to show the construction of the vaulted ceiling in this area. Trace all gravity loads to the <br /> foundation and verify lateral loads for wind and seismic. <br /> See sheet 3. Building Section A <br /> 8. Provide section and/or details for exterior cantilevered deck construction, including guard <br /> attachment and placement. See Sheet 1, Left Elevation & detail <br /> 9. Below grade walls in conditioned spaces are required to be insulated with minimum R-21 on the <br /> interior. Provide section drawing at furred walls. See sheet 3. building sections <br /> 10. All headers shall be insulated with minimum R-10 rigid insulation per Table R402.1.1 <br /> WSEC. Show on plans. See sheet 4, Typical Building Wall Section <br /> 11. Projections located in the five-foot side yard setback shall be protected with one-hour fire- <br /> resistance rated construction on the underside of the projection with no openings allowed. <br /> Provide detail for one-hour fire-resistance rated construction at projections. <br /> See detailed note on sheet 3. <br /> 12. Projections shall not extend more than 18 inches into the required setback. The <br /> proposed fireplace extends two feet into the setback, please revise. <br /> See sheet 2 and 3 <br /> 13. A minimum of 75% of lamps in permanently installed lighting fixtures shall be HIGH- <br /> EFFICACY lamps. Provide note on drawings. See note on sheet 2 <br /> 14.The slab-on-grade in the garage shall slope to the main vehicle entry doorway. <br /> See sheet 3 <br /> 15. Provide minimum 36-inch landing not more than 7-3/4 inches below the finished floor at all <br /> entrance/exits. Show on plans. See sheet 2 <br /> 16.Specify size and location of all egress windows in entire dwelling. See sheet 2 <br /> 17.Show how the Family room in the Basement is provided with light per section R303.1IRC. <br /> See sheet 2 <br /> 18.Specify which 'Whole House Ventilation System" will be used for compliance with section <br /> M1507.3 IRC. Show the requirements of the section chosen,do not simply reference the, <br /> code section. See note on sheet 2. existing laundry <br /> Laurente Vital plans@americanhonieplanners corn (425) 258-6400 <br />