My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1511 OAKES AVE 2025-01-27
>
Address Records
>
OAKES AVE
>
1511
>
1511 OAKES AVE 2025-01-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/27/2025 3:34:56 PM
Creation date
11/21/2024 9:37:49 AM
Metadata
Fields
Template:
Address Document
Street Name
OAKES AVE
Street Number
1511
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
81
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CITY OF EVERETT <br /> Public Works Department <br /> March 19,2019 17A-rt'E ; IJ\\e,) <br /> Owner: Wilkinson <br /> Job Address: 1511 Oakes Ave, Plan CITY OF EVE R FTT <br /> Check No: C1810-003 Permit Services <br /> RE: Building Permit Review Letter <br /> Dear Mr. Vital, l.aurente Vital plans@americanhomeplanners.com (425) 258-6400 <br /> In response to the application for a building permit,the plans have been examined and you are advised <br /> that revisions may be necessary before a permit can be issued. Please review and respond to the <br /> comments below. <br /> All items in the previous correction letter (listed below) are required to be addressed prior <br /> to a building permit being issued. <br /> The structure in its current condition is subject to condemnation if the corrections listed <br /> below are not addressed. <br /> 1. Provide an evaluation of the existing structure, specifically the area of the vaulted ceiling, <br /> prepared by a licensed engineer for wind and seismic loading of the existing configuration and <br /> the gravity calculations from the additional load of the roof trusses in the proposed addition. <br /> Wind& seismic was evaluated for the entire structure the very 1st time the plans was submitted <br /> with calcs and indicated on the floor plans with shear walls and holdowns. <br /> For gravity additional load see attached calcs. <br /> Also see Building Section A, sheet 3 for load path. <br /> 2. Show how the vaulted ceiling in the existing residence is ventilated, and insulated. <br /> See Building Section A. <br /> 3. Projections (cantilevers and roof overhang) in the five foot side yard setback are required to <br /> be one-hour fire-resistance rated construction on the underside of the projection with no <br /> openings allowed. Show how the vaulted area of the residence is provided with one-hour fire- <br /> resistance rated construction.This would also include the overhang in the area of the vaulted <br /> ceiling of the existing residence. <br /> See Building Section A. <br /> 4. Provide detail of fire blocking at concealed spaces of furred walls in the lower level. <br /> See Building Section A. <br /> 5. Walls located in the five-foot side yard setback are required to be one-hour fire- resistance <br /> rated construction.Finishing the basement in the existing structure triggers the requirement for <br /> one-hour fire-resistance rated construction on the south wall. <br /> See Building Section A. <br /> 6. Provide minimum 36-inch landing not more than 7-3/4 inches below the finished floor at all <br /> entrance/exits. Show on plans. <br /> This item is already been on the floor plan. See front door entry and entry from the garage. <br />
The URL can be used to link to this page
Your browser does not support the video tag.