My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2418 74TH ST SE 2023 Plans 2024-11-26
>
Address Records
>
74TH ST SE
>
2418
>
Plans
>
2418 74TH ST SE 2023 Plans 2024-11-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/26/2024 10:40:43 AM
Creation date
11/26/2024 10:39:59 AM
Metadata
Fields
Template:
Address Document
Street Name
74TH ST SE
Street Number
2418
Permit
B2301-019
Year
2023
Notes
INSTALLATION OF (4) HELICAL PILES TO STABILIZE FOUNDATION
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
5 of 21 <br /> GENERAL NOTES <br /> STRUCTURAL STEEL <br /> 1. REFERENCE STANDARDS: DESIGN, FABRICATION AND ERECTION ARE TO BE IN ACCORDANCE <br /> WITH THE LATEST EDITION OF THE AISC"CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS <br /> AND BRIDGES". <br /> 2. MATERIALS: <br /> BOLTS-ASTM A307, UNLESS OTHERWISE NOTED <br /> ALL OTHER STEEL-ASTM A36 (Fy= 36,000 PSI) <br /> 3. ALL WELDING SHALL BE PERFORMED BY CERTIFIED WELDERS AND CONFORM TO AWS CODES <br /> D1.1 AND D1.3.WELDS NOT SPECIFIED ARE TO BE 1/4" CONTINUOUS FILLET MINIMUM. USE DRY <br /> E70 ELECTRODES.WHERE ON-SITE WELDING IS REQUIRED, SPECIAL INSPECTION IN <br /> ACCORDANCE WITH 2018 AND 2012 IBC SECTION 1705.2 IS ALSO REQUIRED. <br /> CONCRETE <br /> 1. REFERENCE STANDARDS:ACI 301,ACI 318, IBC. <br /> 2. MINIMUM CONCRETE STRENGTH (28 DAYS): <br /> FOOTINGS AND STEM WALLS 3,000 PSI -5 SACK MIX <br /> BASEMENT FOUNDATION RETAINING WALLS 3,000 PSI -5 SACK MIX <br /> SLAB-ON-GRADE 2,500 PSI -5 SACK MIX <br /> SLAB-ON-GRADE...EXPOSED WEATHERING SURFACES 3,000 PSI <br /> AIR-ENTRAINMENT 2.5%TO 5.5% FOR EXPOSED CONCRETE <br /> 3. MIXING: COMPLY WITH ACI 301. DO NOT EXCEED THE AMOUNT OF WATER SPECIFIED IN THE <br /> APPROVED MIX. PROPORTIONS OF AGGREGATE TO CEMENT SHALL BE SUCH AS TO PRODUCE A <br /> DENSE,WORKABLE MIX WHICH CAN BE PLACED WITHOUT SEGREGATION OR EXCESS FREE <br /> SURFACE WATER. <br /> 4. PLACING: COMPLY WITH ACI 301. PROVIDE A 3/4 INCH CHAMFER AT ALL EXPOSED CONCRETE <br /> EDGES, UNLESS INDICATED OTHERWISE ON ARCHITECTURAL DRAWINGS. <br /> 5. SLUMP: 4 INCHES PLUS OR MINUS 1 INCH. DO NOT ADD WATER TO MIX TO INCREASE SLUMP. <br /> GREATER SLUMP,ACCELERATED SET, OR HIGH EARLY STRENGTH MAY BE ACHIEVED BY USING <br /> APPROVED ADMIXTURES. <br /> 6. CURING: COMPLY WITH ACI 301. KEEP CONCRETE MOIST FOR SEVEN DAYS MINIMUM. <br /> 7. JOINTING: PROVIDE ADEQUATE JOINTING TO MINIMIZE EFFECTS OF VOLUME CHANGE. JOINTS <br /> SHOWN MAY BE ADJUSTED AT CONTRACTOR'S OPTION WITH PRIOR APPROVAL FROM ENGINEER. <br /> 8. WEATHER EXTREMES: COMPLY WITH ACI 305R FOR HOT WEATHER. COMPLY WITH ACI-306R FOR <br /> COLD WEATHER. <br /> 9. WATER/CEMENT RATIO SHALL NOT EXCEED 0.50 (BY WEIGHT),TYPICAL. <br /> 10. ALL SPECIFIED CONCRETE ANCHORS SHALL BE SIMPSON STRONG-TIE, HILTI, OR EQUIVALENT. <br /> SPECIAL INSPECTIONS REQUIRED.ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH <br /> MINIMUM EMBEDMENT, SPACING, EDGE DISTANCE,AND REQUIREMENTS PER MANUFACTURER. <br />
The URL can be used to link to this page
Your browser does not support the video tag.