Notes
INSTALLATION OF (4) HELICAL PILES TO STABILIZE FOUNDATION
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4 of 21 <br /> GENERAL NOTES <br /> HELICAL PILES <br /> 1. HELICAL PILES SHALL BE DESIGNED AND MANUFACTURED IN ACCORDANCE WITH THE 2018 <br /> INTERNATIONAL BUILDING CODE (IBC). <br /> 2. HELICAL PILES SHALL BE DESIGNED AND MANUFACTURED BY IDEAL MANUFACTURING, INC.,AND <br /> SHALL BE IN ACCORDANCE WITH ESR-3750. <br /> 3. ALL MATERIAL PROPERTIES OF HELICAL PILE COMPONENTS SHALL BE IN ACCORDANCE WITH <br /> ESR-3750. <br /> 4. CORROSION PROTECTION OF ALL PILE COMPONENTS SHALL COMPLY WITH THE ICC-ES <br /> ACCEPTANCE CRITERIA FOR CORROSION PROTECTION OF STEEL FOUNDATION SYSTEMS USING <br /> POLYMER(EAA)COATINGS (AC228). <br /> 5. ALL HELICAL FOUNDATION COMPONENTS SHALL BE GALVANICALLY ISOLATED FROM CONCRETE <br /> REINFORCING STEEL, BUILDING STRUCTURAL STEEL, OR ANY OTHER METAL BUILDING <br /> COMPONENTS PER AC358 SECTION 3.9. <br /> 6. THE SHAFT SHALL BE DESIGNED AND FABRICATED TO SUPPORT THE SPECIFIED DESIGN LOADS. <br /> 7. ONLY MANUFACTURER-APPROVED CONNECTORS, ADAPTORS,AND ACCESSORIES MAY BE USED. <br /> 8. HELICAL PILES SHALL BE INSTALLED VERTICALLY INTO THE GROUND WITH AN ALLOWABLE ANGLE <br /> OF INCLINATION OF+/- 1 DEGREE FROM VERTICAL PER SECTION 4.2.1 OF ESR-3750. <br /> 9. MONITOR AND RECORD DEPTH OF PILE PENETRATION. PROVIDE TORQUE MONITORING DEVICE <br /> AS PART OF THE INSTALLING UNIT. MONITOR AND RECORD TORQUE APPLIED DURING THE <br /> INSTALLATION OF EACH PILE AT SPECIFIC DEPTHS. <br /> 10. HELICAL PILES SHALL BE INSTALLED TO THE MINIMUM TORQUE VALUE REQUIRED TO PROVIDE <br /> THE MINIMUM REQUIRED LOAD CAPACITIES INDICATED ON PLAN INCLUDING A FACTOR OF <br /> SAFETY NO LESS THAN TWO(2). THE MAXIMUM INSTALLATION TORQUE SHALL NOT EXCEED THE <br /> ALLOWABLE TORSIONAL CAPACITY OF ANY INDIVIDUAL COMPONENT OF THE PILE ASSEMBLY. <br /> 11. ALL BRACKETS AND HELICAL PILE ASSEMBLY COMPONENTS SHALL HAVE ADEQUATE CAPACITY <br /> TO ACHIEVE THE MINIMUM REQUIRED BEARING CAPACITY INCLUDING A FACTOR OF SAFETY NO <br /> LESS THAN TWO (2). <br /> 12. REPAIR BRACKETS MUST BE CONCENTRICALLY LOADED AND THE BRACKET PLATE MUST BE <br /> FULLY ENGAGED WITH BOTTOM OF CONCRETE FOUNDATION. <br /> 13. ALL HELICAL PILE ASSEMBLY COMPONENTS MUST HAVE ADEQUATE STRENGTH TO DEVELOP THE <br /> TORQUE REQUIRED FOR INSTALLATION AND ALL INDUCED STRESSES. <br /> 14. THE PILE QUANTITY, LAYOUT,AND SPACING INDICATED ON PLAN SHALL NOT BE CHANGED <br /> WITHOUT WRITTEN APPROVAL FROM THE ENGINEER-OF-RECORD PRIOR TO INSTALLATION. <br /> 15. CONTINUOUS SPECIAL INSPECTION IN ACCORDANCE WITH 2018 AND 2012 IBC SECTION 1705.9 <br /> MUST BE PROVIDED FOR THE INSTALLATION OF THE HELICAL PILES AND FOUNDATION <br /> BRACKETS. ITEMS TO BE RECORDED AND CONFIRMED BY THE SPECIAL INSPECTOR MUST <br /> INCLUDE THE FOLLOWING: <br /> A. PRODUCT MANUFACTURER <br /> B. MANUFACTURER'S CERTIFICATION OF THE INSTALLERS <br /> C. PRODUCT TYPE AND CONFIGURATIONS FOR HELICAL PILE LEAD SHAFT SECTIONS, <br /> EXTENSIONS, BRACKETS, BOLTS, THREADED RODS, NUTS, WASHERS, AND TORQUES AS <br /> SPECIFIED IN THIS REPORT AND THE CONSTRUCTION DOCUMENTS <br /> D. INSTALLATION PROCEDURES FOR THE HELICAL PILE SHAFT, INSTALLATION EQUIPMENT <br /> USED,AND THE IDEAL FOUNDATION SYSTEMS INSTALLATION INSTRUCTIONS <br /> E. ANTICIPATED AND ACTUAL PILING DEPTH <br /> F. REQUIRED TARGET INSTALLATION TORQUE OF PILES AND MINIMUM DEPTH OF INSTALLATION <br /> G. INCLINATION AND POSITION OF PILES,TOP OF PILE EXTENSION IN FULL CONTACT WITH <br /> BRACKET, TIGHTNESS OF ALL BOLTS AND EVIDENCE THAT THE PILE FOUNDATION SYSTEMS <br /> ARE INSTALLED BY AN APPROVED IDEAL FOUNDATION SYSTEMS INSTALLER. <br /> 16. PILES IMPROPERLY INSTALLED BECAUSE OF MISLOCATION, MISALIGNMENT, OR FAILURE TO <br /> MEET OTHER SPECIFIED DESIGN/INSTALLATION CRITERIA ARE NOT ACCEPTABLE.ABANDON <br /> REJECTED PILES AND INSTALL ADDITIONAL PILES AS REQUIRED. <br /> HELICAL PILE PROOF TESTING <br /> THE CAPACITY OF THE INSTALLED PILES SHALL BE VERIFIED BY FIELD TESTING OF A MINIMUM THREE <br /> (3) PERCENT OF PILES UP TO FIVE (5) PILES MAXIMUM (ONE (1) MINIMUM) IN ACCORDANCE WITH THE <br /> PROCEDURE OUTLINED IN ASTM D1143 AND/OR THE 2018 SEATTLE BUILDING CODE (SBC).THE <br /> MAXIMUM TEST LOAD SHALL BE TWO-HUNDRED (200)PERCENT OF THE SPECIFIED DESIGN LOAD. <br />