Laserfiche WebLink
# <br />PUD Staff: <br />Project Name: <br />• <br />Requirements and Specifications Pre-Installation Conditions <br />• This measure is for retrofits only. <br />• This measure is not eligible for lodging, 24/7 occupancy, or semi-conditioned spaces. <br />• Connected thermostats are not eligible for an ARC payment.• The existing thermostat is not web-enabled <br />• A building is eligible to receive payments for more than one thermostat. <br />Post-Installation Conditions <br />• The installed connected thermostat must be listed on the Connected Thermostat Qualified Products List (QPL) <br />• Thermostat is connected to the web. <br />• Temperature setback is used for unoccupied hours (heating and/or cooling, as applicable). <br />• Override duration set to three hours or less. <br />• For heat pumps, auxiliary resistance heat lock-out is enabled with appropriate temperature set point. <br />Rebates and Savings <br />Heating Fuel <br />Type Quantity <br />kWh/yr <br />Savings <br />per Unit <br />Rebate <br />per Unit <br />Estimated <br />kWh/yr Savings <br />Total <br />Rebate* <br />Electric 15 906 $200 13,589 $3,000.00 <br />Total Installed Cost*:Total: 15 13,589 $3,000.00 <br />Project Development Incentive: $375.00 <br />*Total Rebate is capped at approved project cost. <br />Eligibility, Documentation Requirements & Process <br />• For existing and new non-residential facilities located in the Snohomish PUD service territory. <br />• Complete and submit this Rebate Application and W9 Form to eebiz@snopud.com. <br />• PUD to verify and send Customer the Participation Agreement for signature. PUD pre-approval is required. <br />• Installation may start upon the receipt of signed Participation Agreement back from Customer. <br />• PUD to verify installation upon completion and collect invoice, which must show installed cost and new equipment purchase date. <br />• PUD to process the Rebates Payment and send check to Customer (or Alternate Payee). <br />$200 per Stat <br /> Energy Services ● eebiz@snopud.com ● www.snopud.com <br />Rob Marks <br />City of Everett Serv Cntr 2024-08 R-ARCConnected Thermostats (Replacing non Web enabled T-stats) <br />Rebate Application <br />• The installed thermostat controls an existing HVAC supply fan serves a single zone. "Invisible zones" are permitted (e.g., separate rooftop units serving different <br />portions of a large retail space). <br />• Heating fuel type of system to be controlled by new thermostat <br />may be electric or gas; and <br />• Fan schedule uses auto mode for unoccupied hours (e.g., during unoccupied hours or holidays, the fan will only run when there is a demand for heating or cooling). <br />• In cases where two or more systems serve spaces that are not separated by physical barriers (e.g., "invisible zones"), simultaneous heating and cooling is eliminated <br />(e.g. by having identical temperature set points and schedules with appropriate dead-bands, or through having network-coordinated controls). <br />$5,940.00 <br />Location <br />Service Center <br />1 <br />Make & Model <br />of New Thermostat <br />(dropdown list) <br />Pelican Wireless Systems - TS250 with Gateway <br />1 2 <br />3 <br />PUD APPROVED <br />By ST on 11/12/24 7:35PM <br />#