1 I 2 I 3 I 4 I 5 I 6 I 7 I 8 I 9 I 10 <br /> ABBREVIATIONS GENERAL NOTES <br /> 1PH SINGLE-PHASE FIXT FIXTURE SWBD OR SB SWITCHBOARD 1. THESE"GENERAL NOTES'SHALL APPLY TO ALL DRAWINGS WITHIN THIS DRAWING SET. <br /> 1P S I NGLE POLE FLA FULL LOAD AMPS SWGR OR SG SWITCHGEAR <br /> 1P TWO-CONDUCTOR FLUOR FLUORESCENT TEL TELEPHONE <br /> FP FIRE PROTECTION TR TAMPER RESISTANT 2. PROTECT ALL EXISTING WORK FROM DAMAGE DURING CONSTRUCTION.ANY DAMAGED MATERIALS,SYSTEMS,COMPONENTS,FINISHES AND THE LIKE,SHALL BE REPAIRED OR REPLACED AT THE EXPENSE OF THE CONTRACTOR TO THE ACCEPTANCE OF THE OWNER. <br /> 3/C THREE-CONDUCTOR FT FEET OR FOOT TV TELEVISION <br /> 3PH THREE-PHASE FU SW FUSED SWITCH TYP TYPICAL <br /> 4/C FOUR-CONDUCTOR 3. BLACKENED OR BOLDED EQUIPMENT INDICATES THE EQUIPMENT SHALL BE PROVIDED AND INSTALLED BY THE CONTRACTOR.GRAY OR GRAY-SCALED EQUIPMENT SHALL BE ASSUMED TO BE EXISTING OR SHOWN FOR EQUIPMENT LOCATION COORDINATION. <br /> A FVNR FULL VOLTAGE NON-REVERSING UFD UNDERFLOOR DUCT A <br /> 4W FOUR-WIRE FVR FULL VOLTAGE REVERSING UGND UNDERGROUND <br /> A/C AIR CONDITIONING UNIT G ELECTRICAL GROUND UL UNDERWRITERS LABORATORY 4. EXISTING CIRCUITS ASSOCIATED WITH THE PROJECT AREA OF WORK ARE TO BE DE-ENERGIZED DURING CONSTRUCTION. <br /> A/E ARCHITECT/ENGINEER AAP ALARM ANNUNCIATOR PANEL GEN GENERATOR LION UNLESS OTHERWISE NOTED <br /> AC ALTERNATING CURRENT OR ARMORED CABLE GFCI GROUND FAULT UPS UNINTERRUPTIBLE POWER 5. ALL ELECTRICAL WORK SHALL BE COMPLETED WITH ALL PROXIMATE ELECTRICAL CIRCUITS DE-ENERGIZED(i.e.A NEW BREAKER OR CIRCUIT CANNOT BE ADDED TO A PANEL UNLESS THE PANEL IS COMPLETELY DE-ENERGIZED),OR THE CONTRACTOR MUST COMPLY WITH NFPA 70E FOR WORK ON ENERGIZED SERVICE.IF THE WORK MUST BE DONE WITH THE <br /> ACC ACCESSIBLE CIRCUIT INTERRUPTER POWER SUPPLY SERVICE LIVE,THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL REQUIRED PROTECTIVE TOOLS,EQUIPMENT,AND CLOTHING,AND MUST FOLLOW THE JOB SPECIFIC WORK PLAN PREPARED BY THE CONTRACTOR.WORK THAT REQUIRES SHUTTING DOWN ELECTRICAL SERVICE MAY HAVE TO BE ACCOMPLISHED DURING OTHER THAN NORMAL DUTY HOURS. <br /> ADDL ADDITIONAL GFP GROUND FAULT PROTECTION UTIL UTILITY <br /> ADJ ADJACENT,ADJOINING GND GROUND V VOLT 6. WHERE NOT SPECIFICALLY INDICATED ON DRAWINGS,BRANCH CIRCUIT CONDUCTORS SHALL BE 12 AWG MINIMUM FOR RUNS EQUAL TO OR LESS THAN 65 FEET AND 10 AWG MINIMUM FOR RUNS GREATER THAN 65 FEET.RACEWAYS AND CONDUCTORS SHALL BE SIZED AND QUANTIFIED TO SERVE AND CONTROL APPLICABLE EQUIPMENT WITH VOLTAGE DROP NO <br /> AF AMPERE FRAME OR AMP FUSE VA VOLT AMPERE <br /> HID HIGH INTENSITY DISCHARGE VAR VOLT AMPERE REACTIVE GREATER THAN THREE PERCENT.CONDUCTOR SIZE SHALL BE INCREASED TO COMPENSATE FOR DEBATING REQUIRED PER NEC 310.15 WHERE MORE THAN THREE CURRENT CARRYING CONDUCTORS WITHIN ONE RACEWAY;CONDUCTOR AMPACITIES SHALL BE TAKEN FROM THE 75°C COLUMN.INDIVIDUAL CIRCUITS SHALL NOT SHARE NEUTRAL CONDUCTORS. <br /> AFC ABOVE FINISHED COUNTER,AUTOMATIC HOA HAND-OFF-AUTOMATIC <br /> FREQUENCY CONTROL,OR AVAILABLE HP HORSEPOWER VD VOLTAGE DROP <br /> FAULT CURRENT VFD VARIABLE FREQUENCY DRIVE 7. MINIMUM CONDUIT SIZE SHALL BE 1"FOR EXTERIOR AND UNDERGROUND CONDUIT.MINIMUM CONDUIT SIZE SHALL BE 3/4"FOR INTERIOR CONDUIT.ADDITIONAL CONDUCTORS FOR UNSWITCHED HOT CONDUCTOR TO LUMINIARES WITH EMERGENCY BATTERY POWERED BACKUP UNITS OR TRANSFER DEVICES SHALL BE PROVIDED.ALL CONDUIT SHALL BE <br /> HT HEIGHT VOLT VOLTAGE CONCEALED.THE ABOVE COMMENTS SHALL BE ADHERED TO UNLESS OTHERWISE NOTED ON THE DRAWINGS. <br /> AFCI ARC-FAULT CURRENT INTERRUPTER HTR HEATER <br /> AFT ABOVE FINISHED FLOOR HZ HERTZ W WATT/WEATHERPROOF <br /> AFG ABOVE FINISHED GRADE IG ISOLATED GROUND (WHILE IN USE) 8. PROVIDE ALL CONDUIT AND WIRE FOR ALL CIRCUITS INDICATED AND/OR NOTED ON THE DRAWINGS AND/OR SPECIFICATIONS.ALL AUXILIARY OR REQUIRED APPURTENANCES FOR PROVIDED EQUIPMENT SHALL BE PROVIDED WITH ALL CONNECTIONS AS REQUIRED. <br /> Ah AMPERE HOUR IESNA ILLUMINATION ENGINEERING WH WATER HEATER <br /> AHJ AUTHORITY HAVING JURISDICTION SOCIETY OF NORTH AMERICA WPM WEATHERPROOF 9. ALL EQUIPMENT AND INSTALLATION METHODS SHALL BE LISTED AND LABELED PER NEC,UL LISTED,OR REVIEWED EQUAL. <br /> AIC AMPERE INTERRUPTING CAPACITY IMC INTERMEDIATE METAL CONDUIT XFER TRANSFER <br /> ALT ALTERNATE INCAND INCANDESCENT XFMR TRANSFORMER <br /> AMB AMBIENT IR INFRARED 10. EACH BRANCH CIRCUIT HOMERUN SHALL HAVE NO MORE THAN THREE CIRCUITS.EACH BRANCH CIRCUIT HOMERUN SHALL HAVE A SEPARATE GREEN INSULATED EQUIPMENT GROUNDING CONDUCTOR SIZED PER NEC TABLE 250.122.ALL WIRING IS BASED ON CU COPPER PER NEC TABLE 310.15(B)(16),USING 75°C AMPACITIES FOR FEEDERS. <br /> B AMP AMPERE IWH INSTANTANEOUS WATER HEATER B <br /> ARCH ARCHITECT J-BOX JUNCTION BOX 11. FOR EXISTING EQUIPMENT,SUCH AS LIGHTING FIXTURES,WIRING DEVICES,CONDUITS,ETC.,SHOWN ON PLANS TO BE REMOVED,COMPLETELY CUT/CAP CONDUITS AT THE AREA OF WORK PERIMETER AND REMOVE CONDUIT WITHIN THE WORK AREA,DISCONNECT WIRING AT THE OVERCURRENT PROTECTIVE DEVICE AND REMOVE WIRING COMPLETELY FROM THE <br /> ASC AMPS SHORT CIRCUIT kV KILOVOLT ABANDONED CONDUITS. <br /> AT AMPERE TRIP kVA KILOVOLTAMPERE <br /> ATS AUTOMATIC TRANSFER SWITCH AR KILOVOLT AMPERE PER HOUR W <br /> AUTO AUTOMATIC WAR KILOVOLT AMPERE REACTIVE 12. DISCONNECT ALL ABANDONED WIRING OF ALL TYPES AT THE OVERCURRENT PROTECTIVE DEVICE.COMPLETELY REMOVE ALL ABANDONED WIRING. <br /> AV AUDIO VISUAL kW KILOWATT <br /> BAT BATTERY kWh KILOWATT HOUR 13. MAINTAIN AND RESTORE,IF INTERUPTED,ALL CONDUITS AND CONDUCTORS PASSING THROUGH RENOVATED AREAS AND SERVICING UNDISTRIBUTED AREAS. <br /> BD BOARD kWhM KILOWATT HOUR METER <br /> BFF BELOW FINISH FLOOR LCP LIGHTING CONTROL PANEL 14. ALL SURGE PROTECTION DEVICES(SPD)AND DIGITAL POWER METERS(DPM)PROVIDED SHALL BE INTEGRAL TO THE EQUIPMENT IT IS PROTECTING/MONITORING,UNLESS OTHERWISE NOTED. <br /> BLDG BUILDING LED LIGHT EMITTING DIODE <br /> BRKR BREAKER LF LINEAR FEET(FOOT) <br /> BYP BY PASS LP LIGHT POLE 15. CONTRACTOR SHALL DISPOSE OF REMOVED DEVICES.DISPOSAL OF DEVICES SHALL COMPLY WITH ALL APPROPRIATE CODES. <br /> C CONDUIT LPS LOW PRESSURE SODIUM <br /> CAB CABINET LRA LOCKED ROTOR AMPS <br /> CALC CALCULATE LT LIGHT <br /> CAP CAPACITY LTG LIGHTING <br /> CAT CATALOG LTG PNL LIGHTING PANEL <br /> CAN COMMUNITY ANTENNA TELEVISION LTNG LIGHTNING <br /> CCR CONTROL CONTACTOR LV LOW VOLTAGE <br /> C CCTV CLOSED CIRCUIT TELEVISION MAX MAXIMUM C <br /> cd CANDELA MC METAL-CLAD <br /> CD CONSTRUCTION DOCUMENTS MCA MINIMUM CIRCUIT AMPS <br /> CIF CONTRACTOR FURNISHED MCB MAIN CIRCUIT BREAKER <br /> CF/CI CONTRACTOR FURNISHED/ MCC MOTOR CONTROL CENTER <br /> CONTRACTOR INSTALLED MDP MAIN DISTRIBUTION PANEL <br /> CF/01 CONTRACTOR FURNISHED/ MECH MECHANICAL <br /> OWNER INSTALLED MH MANHOLE <br /> CFE CONTRACTOR FURNISHED EQUIPMENT MIN MINIMUM <br /> CHW CHILLED WATER MOCP MAXIMUM OVERCURRENT PROTECTION <br /> C CHILLED WATER PUMP MI MAIN LUGS ONLY <br /> CKT CIRCUIT C/B CIRCUIT BREAKER MS MOTOR STARTER <br /> MT MOUNT <br /> CL CONNECTOR LIGHTING MTD MOUNTED <br /> CLF CURRENT LIMITING FUSE MTG MOUNTING <br /> CLG CEILING MTS MANUAL TRANSFER SWITCH <br /> CO CONDUIT ONLY MV MEDIUM VOLTAGE <br /> COAX COAX CABLE MVA MEGAVOLT-AMPERE <br /> COMM COMMUNICATION MW MEGAWATT <br /> COMPT COMPARTMENT NA NOTAPPLICABLE <br /> D CONIC CONCRETE NAC ANOTIFICATION APPLIANCE CABINET D <br /> CONT CONTINUE NC NORMALLY CLOSED <br /> CONTR CONTRACTOR NEC NATIONAL ELECTRICAL CODE <br /> COORD COORDINATE NEMA NATIONAL ELECTRICAL <br /> CPT CONTROL POWER TRANSFORMER MANUFACTURERS ASSOCIATION <br /> CRI COLOR RENDERING INDEX NEUT,N NEUTRAL <br /> CT CURRENTTRANSFORMER NFC NOT FOR CONSTRUCTION <br /> CTV CABLE TELEVISION NFPA NATIONAL FIRE PROTECTION ASSOCIATION <br /> CU COPPER NIC NOT IN CONTRACT <br /> CUR CURRENT NIL NIGHT LIGHT <br /> _ dB DECIBEL NO NORMALLY OPEN <br /> DC DIRECT CURRENT NITS NOT TO SCALE <br /> DCP DIMMER CONTROL PANEL OC ON CENTER <br /> DDC DIRECT DIGITAL CONTROLS OD OUTSIDE DIAMETER <br /> DEG C DEGREES CELSIUS OH OVERHEAD <br /> DEG F DEGREES FAHRENHEIT OL OVERLOAD <br /> DEMO DEMOLITION OS OCCUPANCY SENSOR <br /> DIAG DIAGRAM P POLE <br /> DISC DISCONNECT PB PULL BOX <br /> DP DISTRIBUTION PANEL PEC PHOTOELECTRIC CELL <br /> DMR SW DIMMER SWITCH PED PEDESTAL <br /> E DPDT DOUBLE POLE,DOUBLE THROW PEND PENDANT E <br /> DPST DOUBLE POLE,SINGLE THROW PIV POST INDICATOR VALVE <br /> DRSW DOOR SWITCH PF POWER FACTOR <br /> DS DISCONNECT SWITCH PH PHASE <br /> DWG DRAWING PNL PANEL <br /> EC ELECTRICAL CONTRACTOR PS POWER SUPPLY <br /> EL ELEVATION OR EXISTING TO PT POTENTIAL TRANSFORMER <br /> BE RELOCATED PVC POLYVINYL CHLORIDE(PLASTIC) <br /> ELEC ELECTRIC OR ELECTRICAL PWR POWER <br /> _ ELEV ELEVATOR R EXISTING TO BE REMOVED <br /> EMER/EM EMERGENCY RCP REFLECTED CEILING PLAN <br /> EMI ELECTROMAGNETIC INTERFERENCE REC RECESSED <br /> EMT ELECTRICAL METALLIC TUBING RECPT RECEPTACLE <br /> EN EXISTING IN NEW LOCATION RM ROOM <br /> ENCL ENCLOSURE RMC RIGID METAL CONDUIT <br /> EPO EMERGENCY POWER OFF RMS ROOT MEAN SQUARE <br /> EPRF EXPLOSION PROOF REQD REQUIRED <br /> ER EXISTING TO REMAIN SAC SMALL APPLIANCE CIRCUIT <br /> ESMT EASEMENT SCC SHORT CIRCUIT CAPACITY <br /> EWC ELECTRIC WATER COOLER SO SMOKE DETECTOR <br /> F EWH ELECTRIC WATER HEATER SF SQUARE FOOT(FEET) F <br /> EXIST(E) EXISTING SHT SHEET <br /> FA FIRE ALARM SI INTERNATIONAL SYSTEM OF UNITS <br /> FAAP FIRE ALARM ANNUNCIATOR PANEL SM SMART METER <br /> FACP FIRE ALARM CONTROL PANEL SPD SURGE PROTECTIVE DEVICE <br /> FC FOOTCANDLE SPEC SPECIFICATION <br /> FCIO FURNISHED BY CONTRACTOR, SPST SINGLE POLE,SINGLE THROW <br /> INSTALLED BY OWNER SURF SURFACE <br /> FDIC FURNISHED BY OWNER, SW SWITCH <br /> INSTALLED BY CONTRACTOR <br /> Drawing Title Phase Project Title Project Number <br /> STAMP CONSULTANT/DISCIPLINE ARCHITECT/ENGINEER OF RECORD ABBREVIATIONS,GENERAL NOTES, AND CONSTRUCTION SET CNC AT SKILLS CENTER �14023001 66 <br /> DISCIPLINE: A/E: <br /> �O�oS�S��cO GENERAL SYMBOLS ELECTRICAL ENGINEERING Building Number <br /> SPEES DESIGN BUILD RAH AEC <br /> tiP TO 23830 PACIFIC HIGHWAY S.SUITE 203 210 Shadow Lane NE <br /> Location Drawing Number <br /> KENT,WA 98032 Olympia,WA 98506 O R4H <br /> 9001 AIRPORT RD EVERETT,WA 98204-1423 <br /> Mukilteo School District Issue Date Checked Drawn E-001 <br /> CONSTRUCTION SET 0910612024 Po�F9 FOiST <br /> NAt_Eo � SPEESDESICNBUILD u <br /> m $/ N RESPONSIVE ACCOUNTABLE HUMBLE r O_O 09/O6/2024 SGG/WNM JFO/JGD 02 OF 07 <br /> Revisions: Date: <br /> 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 1 10 <br />