1 I 2 I 3 I 4 I 5 I 6 I 7 I 8 I 9 I 10 <br /> GENERAL NOTES <br /> 1. COORDINATE WITH OWNERS AGENT FOR FINAL LOCATIONS <br /> OF EQUIPMENT PRIOR TO ROUGH-IN. <br /> 2. MAKE ALL CONNECTIONS TO EQUIPMENT PER <br /> MANUFACTURER'S REQUIREMENTS. <br /> A <br /> 3. REFERENCE CORRESPONDING ONE-LINE DIAGRAM FOR <br /> ADDITIONAL INFORMATION. <br /> 4. CONTRACTOR SHALL PROVIDE UPDATED CIRCUIT PANEL <br /> DIRECTORIES FOR ALL PANELS THAT CONTAIN CIRCUITS <br /> IMPACTED BY THIS PROJECT. <br /> TI I I I I I <br /> UTILITY METER SWITCHBOARD <br /> #366 1772 258 MDC-SB' <br /> UTILITY XFMR <br /> XFMR'PLUG BUS' pANEL'M' <br /> XFMR'PLUG BUS DISC.SEC.' O <br /> 3\DISCONNECT'HH DISC.' <br /> XFMR'HH' <br /> SWITCHBOARD'MDP2' — — — — — — — — — — — — — — — — — — — — U <br /> I <br /> - - - - - - - - - - - - - - - - - - --- KEY NOTES C <br /> PANEL'G' 1O EXISTING EQUIPMENT SHALL BE MODIFIED.REFERENCE <br /> ONE-LINE DIAGRAMS ON SHEET E-601 FOR ADDITIONAL <br /> PANEL'H1' INFORMATION. <br /> O PROVIDE AND ROUTE FEEDER AS INDICATED TO SERVE <br /> _ _ _ _ _ _ _ _ _ _ _ PANEL'H2' _ _ _ _ _ _ _ — �' 'CNC-1'.REFERENCE ONE-LINE DIAGRAMS ON SHEET E-601 <br /> FOR FEEDER SIZING. <br /> PANEL'HH' 1O O EXISTING EQUIPMENT SHALL BE REPLACED.ALL EXISTING <br /> RACEWAYS AND CONDUCTORS SHALL BE PRESERVED AND <br /> PROTECTED FOR RE-TERMINATION.PROVIDE DISCONNECT <br /> 'HH DISC'TO REPLACE ENCLOSED CIRCUIT BREAKER <br /> 'ECB-HH'TO POWER PANELBOARD'HH'.REFERENCE <br /> — — — — — — — — — — — — — — — — — — ONE-LINE DIAGRAMS ON SHEET E-601 FOR ADDITIONAL <br /> E INFORMATION. <br /> I <br /> 2 <br /> D D <br /> I I <br /> — — — — — — Lr <br /> 1 — —I — — — — — — �' <br /> I I <br /> H — — — — — — — — — — — <br /> I I I I <br /> E E <br /> I I I I I <br /> 2 3 4 5 6 7 <br /> F POWER PLAN PR°R"T F <br /> SCALE:1"=10'-0" p <br /> Drawing Title Phase Project Title Project Number <br /> STAMP CONSULTANT/DISCIPLINE ARCHITECT/ENGINEER OF RECORD POWER PLAN CONSTRUCTION SET CNC AT SKILLS CENTER- 1402300166 <br /> �ox�\sWAsir2kO DISCIPLINE: A/E: ELECTRICAL ENGINEERING Building Number <br /> oe & SPEES DESIGN BUILD RAH AEC <br /> 23830 PACIFIC HIGHWAY S.SUITE 203 210 Shadow Lane NE <br /> KENT,WA 98032 Olympia,WA 98506 D Location Drawing Number <br /> �O RAH 9001 AIRPORT RD EVERETT WA 98204-1423 <br /> P°� F� a ��`� : SPEESDESIGNBUILD 0_o <br /> Mukilteo School District Issue Date Checked Drawn E-101 <br /> LL CONSTRUCTION SET 0910612024 ASS/ONALEN� 09/06/2024 SGG/WNM JFO/JGD <br /> Revisions: Date: El. RESPONSIVE ACCOUNTABLE HUMBLE OS OFW <br /> 1 1 2 I 3 I 4 I 5 1 6 I 7 1 8 1 9 I 10 <br />