Laserfiche WebLink
III <br /> THERMO Peak-performance <br /> 2000 heating systems Revision 0—February 2019 <br /> o Operating mode: electric, auxiliary or dual-energy <br /> o "Boost" mode in operation <br /> o "Warm Weather Shut Down": The boiler shuts down when the outdoor temperature is high <br /> o Visual and audible alarm with alarm code <br /> o Operating status indicator lights: green, amber or red <br /> o Unit(°C/°F) and language (English/French) selector <br /> o Return temperature display <br /> o Boiler flow-rate display <br /> o Display of amperage measured at the boiler <br /> o Power consumption estimate display <br /> 2. TEMPERATURE ADJUSTMENT <br /> • Adjustable set point temperature ranges from 50OF to 200OF (10°C to 93°C) <br /> • There are different ways to control the set point temperature: <br /> 1. Fixed set point temperature <br /> 2. Water temperature modulation via the outdoor temperature sensor <br /> 3. Remote water temperature control using an external BACnet IP or MSTP controller <br /> 4. Variable water temperature based on a building occupancy schedule <br /> • The controller can be used to set a second, higher set point temperature, which allows you to use an indirect water <br /> heater with or without domestic hot water priority. <br /> • "Boost" mode to automatically increase the temperature when demand persists <br /> • Exterior temperature sensor included <br /> • "Warm Weather Shut Down": The boiler shuts down when the outdoor temperature is high <br /> • External 0-10Vdc temperature control <br /> 3. POWER ADJUSTMENT <br /> • The maximum power can be controlled as follows: <br /> 1. The controller has no constraints or limitations <br /> 2. The maximum power is controlled manually <br /> 3. Maximum power modulated based on the sensor's outdoor temperature <br /> 4. Remote power control (using an external BACnet IP or MSTP controller) <br /> 5. Variable maximum power based on a pre-set schedule <br /> • External 0-10Vdc power control <br /> • Auxiliary energy source used as a backup or master <br /> 4. CONNECTIVITY <br /> • Ethernet and BACnet network communication ports enable remote communication <br /> • Standard BACnet IP or MSTP network communication <br /> • Ability to view the operating status and to remotely modify the settings on a webpage <br /> • Operating anomalies information and history <br /> • Can be configured to send alarms by email <br /> THERMO 2000 INC <br /> 500, 9th avenue, Richmond (Quebec) JOB 2H0 <br /> TEL.: 819-826-5613 FAX: 819-826-6370 <br />