Laserfiche WebLink
Confidential Draft Hydrogen Fueling Station Performance Validation Testing—DO NOT CITE OR QUOTE <br /> HyStEP Summary Test Report for Linde—Mobile Refueler Hydrogen Station Updated Revision Date:September 27,2023 <br /> VI. Table Based Communications Testing Summary <br /> Test Result Comment <br /> Pass Fail <br /> Abort Signal. ® ❑ 1. Abort sent before start:fill didn't start. <br /> 2. Abort sent after 30 sec fueling:terminated immediately with code"5". <br /> 3. Fill started in comm and switched to non-comm and then switched to comm <br /> with abort signal after 30 sec:terminated immediately,with code"5". <br /> Halt Signal. ® ❑ Halt signal after 30 sec fueling:terminated immediately <br /> Data Loss Test Then ® ❑ Switched to Non-Comm on hystep after 30 sec fueling,dispenser recalculated Target <br /> Resumes Fueling Pressure to Non-Comm.Switched back to Comm on hystep after 15 sec, dispenser <br /> remained with non-comm target pressure and fueling completed as a non-comm fill. <br /> Invalid CRC ® ❑ Dispenser switched fueling to non-communication after receiving 7 errors within <br /> Communication. 500ms and continued fueling.Test performed three times and dispenser switched to <br /> non-comm target pressures. <br /> Invalid Defined Data Value. An invalid defined data value,dispenser either terminates fueling or continues in non- <br /> communications mode. Perform the following tests and enter the invalid data value used for the individual test. <br /> Data Tag Proper Invalid Result Comment <br /> Data Value Data <br /> Pass Fail <br /> Value <br /> Protocol Identifier ID= SAE" SAEJ2 ® ❑ Dispenser switched to non-communication mode <br /> J2799 799 within—one second and continued fueling. <br /> Communications 00.00- 100.0 ® ❑ Dispenser switched to non-communication mode <br /> Software Version# VN 99.99 within—one second and continued fueling. <br /> 0000.0— ® ❑ Dispenser terminated fueling within in one second, <br /> Tank Volume TV= 5000.0 6000 with dispense code; policy_comm limit. <br /> Receptacle Type RT= H25,H35, H35 ® ❑ Dispenser terminated fueling within in one second, <br /> H50, H70 with dispense code; policy_comm limit. <br /> Fueling Command FC= Dyna,Stat, Dyna1 ® ❑ Dispenser switched to non-communication mode <br /> Halt,Abort within—one second and continued fueling. <br /> Measured Pressure MP= 000.0— 100.1 ® ❑ Dispenser switched to non-communication mode <br /> 100.0 within—one second and continued fueling. <br /> Measured MT= 16.0— 425.1 ® ❑ Dispenser switched to non-communication mode <br /> Temperature 425.0 within—one second and then terminated fueling. <br /> 13 <br /> Page 22 of 38 <br />