My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10524 HOLLY DR Utility Plans 2024-12-04
>
Address Records
>
HOLLY DR
>
10524
>
Utility Plans
>
10524 HOLLY DR Utility Plans 2024-12-04
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2024 11:13:54 AM
Creation date
12/4/2024 10:57:07 AM
Metadata
Fields
Template:
Address Document
Street Name
HOLLY DR
Street Number
10524
Permit
PW1807-010
PW2206-011
Address Document Type
Utility Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7"d TRdr-r-Ir PATH TI-101 WAIT 1/r-AIT <br />SW 1/4, NE 1/4, SEC. 23, T.28 N., R.4 E., W.M. <br />CITY OFEVERETT, WASHINGTON <br />100, <br />IE: 538.5 (IN) <br />MANHOLE RISER <br />WITH GRATED LID <br />11 LF 12" SDR 35 0 0% ` <br />CB#7 - <br />CONTROL STRUCTURE <br />TYPE 2-5410 <br />Rim; 5:51.56 <br />RIM: 542.33 (AB) <br />IE: 532.48 (12" CPP, NE) <br />IR 532.48 (12- CPP, SE)(AB) <br />STEPS <br />SCALE: 1 "-4' '116._) <br />ROUND SOLID COVER MARKED <br />"DRAIN" WITH LOCKING BOLTS <br />UNLESS OTHERWISE APPROVED <br />BY THE ENGINEER <br />ORIFICE 13 = 1.35" DIA. (AB) <br />EL--j_4&8&-538.83(AB) <br />RESTRICTOR PLATE TO BE <br />SHARP EDGED. SHOP DRILLED <br />s. s <br />a <br />'D PIPE SUPPORTS. NO. AS REQ. 539.98(AB) <br />3" X 0.9 GA. BOLTED OR O.F.EL.=:54$- <br />IMBEDDED 2" (MIN.) IN C.B. WALL <br />0 3' (MAX.) SPACING. MIN. 1' SUPPORT <br />12" F. R. 0. P. TEE--, . <br />a. a A <br />DETENTION SUMMARY CHART - WET VAULT <br />STORM <br />EVENT <br />VOLUME STORAGE REQUIREMENTS (CF) <br />MAXIMUM RELEASE RATES (CFS) <br />DEAD <br />LIVE <br />DESIGNED <br />AS -BUILT <br />RATE <br />DESIGNED <br />AS -BUILT <br />2-YEAR <br />4,080 <br />19,322 <br />19,322 <br />19,322 <br />0.07 <br />0.04 <br />0.04 <br />50-YEAR <br />4,080 <br />30,600 <br />30,600 <br />3016W <br />0.22 <br />0.20 <br />0.20 <br />COVER PER <br />F. R. 0. P. TEE <br />FRAME AND LADDER OR STEPS <br />OFFSET. RIM = 5-}-542.33(AB) <br />6" MIN <br />ORIFICE 12 = 1.3" DIA. (AB) <br />EL=55- 5. 537.13(AB) <br />RESTRICTOR PLATE TO BE <br />SHARP EDGED. SHOP DRILLED <br />12"0SD <br />12" 0 SD ® 09 SL. <br />TO CB#8 <br />I.E. = - I.E. _ -5�- 532.48(AB) <br />s .• a .,' <br />532.48 AB 2° <br />DIAMETER OF � ••` <br />THE RAISER: 12" CLEANOUT/ 3 <br />SHEAR GATE C3.2 <br />ORIFICE 41 = 0 817" DIA (AB) <br />RESTRICTOR PLATE TO BE 2' :. <br />SHARP EDGED. SHOP DRILLED <br />54' SM CB. <br />CB17 TYPE 2-54"0 <br />FLOW RESTRICTOR <br />('2' CONTROL DEVICE (F.R.O.P.) <br />�C3J.2 NOT TO SCALE (PER COE STD DWG 415 & 416) <br />NOTE:• <br />A GEOTECH SHALL BE PRESENT DURING VAULT CONSTRUCTION. <br />NOTES: <br />1. SEE STRUCTURAL PLANS FOR MORE DETAILS. <br />2. FOOTING DRAIN FOR THE VAULT SHALL BE DAYLIGHTED. <br />MAXIMUM OPENING <br />OF GATE <br />SCALE: 1" = 10' <br />0 5 10 <br />HANDLE WITH <br />LOCK PIN <br />ADJUSTABLE LOCK <br />HOOK w/LOCK SCREW <br />SIX EVENLY SPACED HOLES ON 10 <br />3/8" BOLT CIRCLE FOR BOLTING <br />TO FLANGE CONNECTION. <br />O o <br />I O <br />I u <br />LEVEL LINE ' O <br />O O <br />O <br />FRONT SIDE <br />LIFT HANDLE SHALL BE ATTACHED PER <br />MANUFACTURER'S RECOMMENDATIONS. <br />ALTERNATES ARE ACCEPTABLE PROVIDED MATERIAL SPECIFICATIONS ARE <br />MET AND FLANGE BOLT PATTERN MATCHES <br />3 CLEANOUT/ SIIEAR GATE <br />C3.2 N. T.S. <br />0 <br />I I t0°O°C <br />III.OoOOC <br />870 INLET - ° ° ° C <br />IE 538.5 <br />?000c <br />NO0 <br />-III to°C <br />III-00C <br />-III � 0 °� <br />_ III _D0C <br />-III �°C <br />0 <br />III�Oc <br />III �oC <br />_ oC <br />-I I I�0c <br />I I F-I <br />EL. <br />529.60(AB) <br />BOTTOM SLOPE 0.5%-2% <br />TOWARDS OUTLET END OF <br />SECOND CELL (RECOMMENDED) <br />RECORD DRAWING <br />This Record Drawing has been prepared, in part, <br />based on "As -Built" information provided by <br />others. Though the as -built information and this <br />drawing are based on the best available <br />information, no presumption should be made <br />regarding the drawing's accuracy. <br />Jim Knappert 07/29/2024 <br />Permit Inspector <br />REMOVABLE <br />WATERTIGHT <br />COUPLING <br />PLATE WITH <br />ORIFICE AS <br />SPECIFIED <br />4 ORIFICEDETAIL <br />��2N.T.S. <br />^ I» - n^# Ill / 111 II/ /I It <br />r•�mia����,url <br />1 WET VAULT SECTION DETAIL <br />C3.Z NOT TO SCALE <br />BOTTOM SLOT 0.5q-2% <br />TOWARDS INLET END <br />0 0 I <br />° 8 70 INLET <br />0 III - 538.90(AB) <br />000�c <br />III III= <br />000� II <br />�ILJ- IL <br />°o°.II III- <br />000 1 <br />o sc� III - <br />000C I I I <br />o°�I <br />III_ <br />II _I <br />'o <br />=1 <br />of II <br />529.65(AB) <br />C I EL: �J-25- <br />I <br />I <br />W <br />0 <br />c� <br />5 x 10' z 24" 0 SOLID LID <br />ACCESS <br />OPENING <br />GROUND EL=543(MIN.) <br />ITOV=540.5 I I I I I <br />° TOP OF PLANK 541.5 a :°. a a :°, a Q 50 <br />539.98 AB <br />--- ---- - �---L--�,------------- ---- - <br />.A, <br />870 INLET <br />IE 538.50(AB) d <br />53Z 13(AB) 00 <br />YR. EL=5:;_ 8 <br />d <br />1270 OUTLET v <br />IE•-5: <br />532.48(AB) AB) <br />WQ DESIGN WS 532.48 ° <br />A9) <br />, . <br />21.2521.25' 21.25' 21.25' <br />d . <br />d AVERAGE 1' SEDIMENT <br />STORAGE (FIRST CELL) <br />- - - - - - - - - - - - - - - <br />d . <br />BorroM - -a - <br />529:6oFB)� d <br />EL <br />III , I 529.WM) <br />III <br />d <br />53om(AB) <br />EL t36 5- d <br />� �EL= •�,9,50_ <br />d 5.29.65(AS) <br />5z 5% 5z 5% <br />Q d <br />.a... III <br />EL_ <br />529.6 AAB) <br />51% (MIN) SLOPE VAULT SECTION C C <br />FROM EL FINISH NOT TO SCALE <br />Know what's below. <br />Call before you dig. <br />UTILITY CONFLICT NOTE.• <br />CAUTION.• <br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, <br />DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE <br />PLANS OR NOT, BY POTHOLING THE UTILITIES AND SURVEYING THE HORIZONTAL <br />AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE <br />CALLING UTILITY LOCATE 0 1-800-424-5555 POTHOLING ALL OF THE EXISTING <br />UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY <br />WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN <br />ON THESE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC INFORMATION AND <br />ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR <br />SHALL CONSULT WITH INSIGHT ENGINEERING COMPANY TO RESOLVE ALL <br />PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. <br />12"0 INTLET <br />IE <br />534.6rAB) <br />
The URL can be used to link to this page
Your browser does not support the video tag.