SYMBOL LEGEND <br /> FACP FIRE ALARM CONTROL PANEL <br /> FAC FIRE ALARM COMMUNICATOR (CELLULAR DIALER) <br /> FATC FIRE ALARM TERMINAL CABINET <br /> RPS FIRE ALARM REMOTE POWER SUPPLY <br /> S PHOTOELECTRIC SMOKE <br /> x:xx DETECTOR, BRIGHT WHITE <br /> SUBSCRIPT X:XX = DEVICE <br /> ADDRESS <br /> Ox:xx ADDRESSABLE HEAT DETECTOR <br /> SUBSCRIPT X:XX = DEVICE ADDRESS <br /> [—Flx:xx MANUAL PULL STATION <br /> SUBSCRIPT XAX = DEVICE ADDRESS <br /> MMM x:xx MINI MONITOR MODULE <br /> SUBSCRIPT X:XX = DEVICE ADDRESS <br /> SMOKE DUCT DETECTOR <br /> (PROVIDED BY OTHERS) <br /> WALL MOUNT HORN STROBE <br /> CD = CANDELA RA ING <br /> WE = WEATHER PROOF <br /> CEILING MOUNT HORN/STROBE <br /> CD = CANDELA RATING <br /> ® WALL MOUNT STROBE <br /> CD = CANDELA, RATING <br /> FIRE ALARM CIRCUITS GENERAL (VOTES <br /> FROM BUIL71NG 7-582 <br /> 1. BUILDING 7-581 & 7-584 ARE ALL <br /> MONITORED BY BUILDING 7-582 FACP <br /> � <br /> 110CDi <br /> D,N REFERENCE DRAWINGS <br /> Al IP77 <br /> ° <br /> F D <br /> MEWS IN 4 F a WOMEN'S <br /> H.C.R.R. C:28Dn <br /> Q 1:25 H.C.R.R. <br /> H 1:27 15CD ° ° 15CD H 1:26 CONSTRUCTION NOTES <br /> _�y_ [!:�:-PROVIDE AND INSTALL NEW DIGITAL <br /> 0 D A <br /> O ADDRESSABLE BUILDING FACP. PROVIDE <br /> /(„ �� A <br /> PHENOLIC LABEL ON PANEL THAT READS: <br /> \LvJ/ "7-582 FIRE ALARM CONTROL PANEL <br /> EVT—FA-7-582 <br /> 120VAC FED FROM PANEL (T.B.D.)" <br /> PROVIDE CELLULAR COMMUNICATOR AND WIRE <br /> TO BUILDING FACP. SEE SHEET E506 FOR <br /> INSTALLATION DETAILS. <br /> PROVIDE AND INSTALL A NEW REMOTE POWER <br /> SUPPLY FOR NOTIFICATION DEVICES. <br /> ®PROVIDE AND INSTALL FIRE ALARM TERMINAL <br /> CABINET FOR INTER—CONNECTION TO BUILDINGS <br /> 7-581 & 7-582 <br /> PROVIDE AND INSTALL NEW HORN/STROBES AS <br /> SHOWN ON PLANS. <br /> PROVIDE AND INSTALL MANUAL PULL STATIONS <br /> 0 <br /> AT EACH EXIT. <br /> PROVIDE AND INSTALL DETECTION DEVICES AS <br /> SHOWN ON PLANS. <br /> PROVIDE AND INSTALL MONITOR MODULES AS <br /> SHOWN ON PLANS. <br /> SEE SHEET E410 FOR ADDITIONAL FIRE ALARM <br /> POINTS. <br /> 5 <br /> SEE SHEET E411 FOR ADDITIONAL FIRE ALARM <br /> POINTS. <br /> I <br /> WIRE TAG DESCRIPTION <br /> CIRCUIT ID CIRCUIT DESCRIPTION WIRE DESCRIPTION <br /> m D FACP SOILS CIRCUIT 4 CONDUCTOR, 16 AWG— FPLP KEY PLAN BLDG. 7—5 8 4 <br /> C — FACP VBUS CIRCUIT 4 CONDUCTOR, 16 AWG— FPLP SCALE: <br /> C �I ��11 �I v <br /> D ——————— FACP SLC CIRCUIT 2 CONDUCTOR, 16 AWG— FPLP SCALE. 1/`F" — 1' <br /> 3 <br /> N --------- NAC CIRCUIT 2 CONDUCTOR, 14 AWG- FPLP <br /> P AUX CIRCUIT 2 CONDUCTOR, 14 AWG- FPLP <br /> V —---—-- VOICE CIRCUIT 2 CONDUCTOR,16 ACE SOL-FPLP 0 4 (�Q �`V 0 Q <br /> Z EQUIPMENT INTERFACE CKT. CONTRACTORS EQUIPMENT WIRING <br /> 0 i 1 <br /> J <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> ACCEPTABILITY J.SHELDON 05 09 24 <br /> w5 DESIGN AND/OR CHECKED FIRE ALARM PLAN A 05/09/24 <br /> A EVERETT 7-584 BLDG FIRE ALARM INSTALLATION 34558629 AGOW/JS AGOW/KM 05/09/24 m SPECIFICATION IS APPROVED K. MULLEN 05 10 24 SHEET SEQUENCE NO.LNUINLLN <br /> � <br /> BOE/A/G APPROVED BY DEPT. DATE K. MULLEN 05 09 24 <br /> TITLE EVERETT FIRE PANEL INSTALLATION E412 <br /> CHECKED w <br /> APPROVED BUILDING 7-584_ <br /> 34558629 <br /> APPROVED DWG NO- <br /> EVERETT, WA. FA—W2-7-582 <br />