REM POWER CABLE (SUPPLIED SYMBOL LEGEND <br /> 6 5 3 4 WITH REM) SEQUENCE OF OPERATIONS FACP I FIRE ALARM CONTROL PANEL <br /> OUTPUT FUNCTIONS F FAC I FIRE ALARM COMMUNICATOR (CELLULAR DIALER) <br /> SYSTEM ICTIO <br /> DITIONAL FATC FIRE ALARM TERMINAL CABINET <br /> ANNUNCIATION& YSTENS MTRANSMISSIONRPS FIRE ALARM REMOTE POWER SUPPLY <br /> ELECTRIC <br /> OKE <br /> Ox:zx DETOECCTOR, BRIGHT WHITE <br /> 3�3/4"C - 2#14THHN,1#14G 'Z 0 � <br /> SUBSCRIPT X:XX = DEVICE ADDRESS <br /> TG PEM RI Ox:zx SUBSCRIPT <br /> ADDRESSABLE <br /> HEAT DEVICE ADDRESS <br /> DETECTOR <br /> O <br /> FACP EVT-FA-7-582 TG—71C S Q �� Ox:zx MANUAL PULL STATION <br /> (BY FIRE ALARM VENDOR) °"" 1 1 4 7 4U• [(/ SUBSCRIPT X:XX = DEVICE ADDRESS <br /> MMM x:xz MINI MONITOR MODULE <br /> =o = O= = SUBSCRIPT X:XX = DEVICE ADDRESS <br /> 3 Jg Q �0 O C= SMOKE DUCT DETECTOR <br /> T Q Q� (PROVIDED BY OTHERS) <br /> DC STC2 STC1 TRIP BATT AC v 42 Ov Z / U V� WALL MOUNT HORN STROBE <br /> 2 1 2 3 4 5 6 1 2 3 1 2 G CD = CANDELA RAPING <br /> 00 PROOF <br /> o� O=O �_ _ �_ � CEILING WP WMOTUN T HORN/STROBE <br /> �,z Q �� ��Q �� Q CD = CANDELA RATING <br /> to <CV Uc �Q = ® GO <br /> MOUNT ROBING <br /> RED EDL(AS NEEDED) QO Jm� <br /> U O <br /> �Q y O� O I� <br /> 3/4"C0-0 <br /> - (1) PHONE CABLE, 2 O m44 �� m�� m�� =zc� GENERAL NOTES <br /> (1) 2 CONDUCTOR FPL OR w Co J 4u � J G J to 0 0 <br /> APPROVED EQUAL INPUT CONDITION ��� e�� Q���Q��y 1. BUILDING 7-581 & <br /> BUILDING 7-582 FACP <br /> 584 ARE ALL MONITORED BY <br /> STANDBY CONDITION(NORMAL) ! i <br /> FIRE ALARM SYSTEM COMMUNICATIONS DETAIL / \ C POWER FAILURE s : • • CONSTRUCTION NOTES <br /> SCALE: NONE E260 E506 w ANY CIRCUIT-OPEN,SHORT,GROUND • i i i PROVIDE CELLULAR DIALER, AND MOUNT ADJACENT TO <br /> SLC DEVICE MISSING i i • • THE BUILDING FACP. CONFIGURE DIALER TO PROVIDE <br /> � <br /> COMM.FAULT/TELGAURD TROUBLE ! ! ! ! SOLE PATH COMMUNICATION. DIALER SHALL BE <br /> BATTERY FAULT-LOW/HIGH VOLTAGE ! s ! ! COMPATIBLE WITH AT&T CELL SERVICE. <br /> PROVIDE (1) CONDUIT PENETRATION FOR PHONE AND <br /> j FIRE ALARM CONNECTIONS. WIRE AS SHOWN. PROVIDE <br /> ADDRESSABLE MODULE AS NECESSARY TO PROVIDE <br /> STEP 1: VERIFY SIGNAL STRENGTH AT PROPOSED LOCATION FOR CELLULAR COMMUNICATOR PANEL INDICATED ON a DUCT SMOKE DETECTORS s s • • GENERAL TROUBLE ALARM FROM CELLULAR DIALER TO <br /> DRAWINGS. IF ACCEPTABLE *SIGNAL STRENGTH IS ACQUIRED, SKIP TO STEP 5. DO <br /> BUILDING FACP. <br /> i <br /> STEP 2: IF ORIGINALLY PROPOSED LOCATION IS INADEQUATE, FIELD TEST *SIGNAL STRENGTH WITHIN A 20FT RADIUS FIRE ALARM PULL STATION OF OF i w PROVIDE (1) CONDUIT PENETRATION FOR 24/12VDC <br /> TO IDENTIFY LOCATION(S) SUITABLE FOR INSTALLATION OF REMOTE/EXTERNAL CELLULAR ANTENNA. a SMOKE DETECTOR • • • • POWER AND EARTH GROUND FROM THE BUILDING FACP <br /> COORDINATE THE FINAL ANTENNA LOCATION WITH BOEING AND SPACE USERS (IF IMPACTED) FOR w HEAT DETECTOR • • • • POWER SUPPLY. PROVIDE POWER AND EXPANSION <br /> APPROVAL PRIOR TO ROUGH-IN AND SKIP TO STEP 4. �_ MODULE AND WIRE AS SHOWN. MAINTAIN <br /> (` MANUFACTURER'S REQUIRED 1/4" SEPARATION <br /> STEP 3: IF ACCEPTABLE *SIGNAL STRENGTH IS NOT ACHIEVED WITHIN 20FT OF ORIGINAL PROPOSED LOCATION FOR BETWEEN POWER AND COMMUNICATION WIRING. <br /> CELLULAR COMMUNICATOR PANEL, PROPOSE ALTERNATE LOCATION FOR CELLULAR PANEL. COORDINATE <br /> WITH BOEING AND SPACE USERS FOR POTENTIAL LOCATIONS, PREFERABLY NEAR ORIGINAL LOCATION. ® PROVIDE PHENOLIC LABEL, WHITE LETTERING, RED <br /> STEP 4: LOCATE AND PROVIDE EXTERNAL CELLULAR ANTENNA, EXTERIOR MOUNTING BRACKET AND COAXIAL CABLE F q BACKGROUND, THAT READS: <br /> FROM CELLULAR COMMUNICATOR TO THE ANTENNA. THE ANTENNA AND PANEL SHOULD BE LOCATED 7-582 BUILDING SYSTEM FACP POINTS <br /> WITHIN 20FT OF EACH OTHER. "FIRE ALARM CELLULAR DIALER" <br /> STEP 5: PROVIDE 24VDC POWER, MONITORING CIRCUIT, AND TELEPHONE LINE TO CELLULAR COMMUNICATOR FROM POINT NUMBER/ZONE BOEING DESCRIPTION FACP POINT - COMMENTS - GRID/SHEET LOC. PROVIDE CELL ANTENNA AND EVALUATE FIELD SIGNAL <br /> BUILDING FACE. L1:01 1 CELL DIALER FAULT CELL DIALER TROUBLE - E410 STRENGTH IN ACCORDANCE WITH DETAIL 2. INSTALL <br /> STEP 6: PROVIDE REQUIRED SET-UP, PROGRAMMING AND TESTING OF CELLULAR COMMUNICATOR EQUIPMENT PER L1:02 2 RPS FAULT NOTIFICATION REMOTE POWER SUPPLY FAULT - E410 CONDUIT AND EXTENDED ANTENNA CABLE AS <br /> THE MANUFACTURER'S INSTRUCTIONS. CELLULAR DIALER SHALL BE CONFIGURED AND INSTALLED AS A L1:03 3 SMOKE @ FACP SMOKE DETECTOR ABOVE FACP - E410 NECESSARY TO REMOTE MOUNT ANTENNA COVERAGE <br /> S NOT SUITABLE AT FACP LOCATION. UPDAA TE ROM <br /> SOLE PATH FOR FIRE COMMUNICATIONS. L1:04 4 7-582 MAN PULL @ DOOR N1 BUILDING 7-582 MANUAL PULL @ DOOR N1 WITH SELECTED CABLE LENGTH AND PROVIDE REDLINES <br /> L1:05 5 7-582 SMOKE DETECTOR BUILDING 7-582 SMOKE DETECTOR - E410 TO BOEING ENGINEER. <br /> *ACCEPTABLE SIGNAL STRENGTH SHALL BE DETERMINED BY MANUFACTURERS SPECIFICATIONS AND LOCAL AHJ L1:06 6 7-582 SMOKE DETECTOR BUILDING 7-582 SMOKE DETECTOR - E410 <br /> FOR REMOTE IN <br /> ORDINANCES. L1:07 7 7-582 SMOKE DETECTOR BUILDING 7-582 SMOKE DETECTOR - E410 © WHITE LETTERINGG,, RED <br /> EDI PROVIDE PHENOLIC LABEL,B BACKGROUND, THAT READS: <br /> L1:08 8 7-582 SMOKE DETECTOR BUILDING 7-582 SMOKE DETECTOR - E410 <br /> CELLULAR COMMUNICATOR INSTALLATION SEQUENCE L1:09 9 7-582 MAN PULL @ DOOR N2 BUILDING 7-582 MANUAL PULL @ DOOR N2 - E410 "FIRE ALARM CELLULAR ANTENNA" <br /> SCALE: NONE L1:10 10 7-582 SMOKE DETECTOR BUILDING 7-582 SMOKE DETECTOR - E410 <br /> E260 E506 L1:11 11 7-582 SW. DUCT. DET. BUILDING 7-582 SMOKE DETECTOR - E410 7INSIDE CELL ENCLOSURE POST COMMUNICATOR <br /> SETTINGS AND CELLUAR PHONE NUMBER. PROVIDE <br /> L1:12 12 7-582 W. DUCT. DET. BUILDING 7-582 SMOKE DETECTOR - E410 PRINTED LABEL, HANDWRITTEN INFORMATION IS NOT <br /> L1:13 13 7-582 NW. DUCT. DET. BUILDING 7-582 SMOKE DETECTOR - E410 ACCEPTABLE. PROVIDE SETTINGS AND CELLULAR <br /> L1:14 14 7-581 SMOKE DETECTOR BUILDING 7-581 SMOKE DETECTOR - E411 INFORMATION TO BOEING ENGINEER. <br /> L1:15 15 7-581 MAN PULL @ DOOR N1 BUILDING 7-581 MANUAL PULL @ DOOR N1 - E411 <br /> L1:16 16 7-581 SMOKE DETECTOR BUILDING 7-581 SMOKE DETECTOR - E411 <br /> L1:17 17 7-581 SMOKE DETECTOR BUILDING 7-581 SMOKE DETECTOR - E411 BILL OF MATERIALS <br /> L1:18 18 7-581 SMOKE DETECTOR BUILDING 7-581 SMOKE DETECTOR - E411 ITEM QTY. PART NO. MANUFACTURER DESCRIPTION <br /> L1:19 19 7-581 SMOKE DETECTOR BUILDING 7-581 SMOKE DETECTOR - E411 1 1 3992753 POTTER FIRE ALARM CONTROL PANEL <br /> L1:20 20 7-581 MAN PULL @ DOOR N2 BUILDING 7-581 MANUAL PULL @ DOOR N2 - E411 2 1 3006436 POTTER REMOTE POWER SUPPLY (6AMP) <br /> L1:21 21 7-581 SMOKE DETECTOR BUILDING 7-581 SMOKE DETECTOR - E411 3 1 3992769 POTTER UD-2000 DACT CARD <br /> L1:22 22 7-581 SW. DUCT. DET. BUILDING 7-581 SMOKE DETECTOR - E411 4 14 3992782 POTTER PAD300 6" BASE <br /> L1:23 23 7-581 W. DUCT. DET. BUILDING 7-581 SMOKE DETECTOR - E411 5 12 3992775 POTTER PAD300 SMOKE DETECTOR <br /> L1:24 24 7-581 NW. DUCT. DET. BUILDING 7-581 SMOKE DETECTOR - E411 6 2 3992776 POTTER PAD300 HEAT DETECTOR <br /> L1:25 25 7-584 MAN PULL @ WOMENS R.R. BUILDING 7-584 WOMENS RESTROOM MANUAL PULL - E412 7 6 3992720 POTTER PAD100 PULL STATION <br /> L1:26 26 7-584 HEAT DET. @ WOMENS R.R. BUILDING 7-584 WOMENS RESTROOM HEAT DETECTOR - E412 8 6 3992700 POTTER PAD100 MICO INPUT MODULE <br /> L1:27 27 7-584 HEAT DET. @ MENS R.R. BUILDING 7-584 MENS RESTROOM HEAT DETECTOR - E412 9 2 SLA1104 POWERPATROL 12VDC 12 AH BATTERIES <br /> 1/ L1:28 28 7-584 MAN PULL @ MENS R.R. BUILDING 7-584 MENS RESTROOM MANUAL PULL - E412 <br /> 10 3 BK-P2RK SYSTEM SENSOR WEATHER PROOF HORN/STROBES <br /> ' BUILDING FACP POINTS LIST /� 11 2 BK-SRLED SYSTEM SENSOR STROBES (WALL MOUNT) <br /> SCALE: NONE m 12 4 BK-PC2RLED SYSTEM SENSOR HORN STROBES CEILING MOUNT <br /> E�06 13 1 TG-7FS-A TELGUARD ATT CELLULAR DIALER <br /> 13 1 ISSU00689 ISPACEAGE IFIRE ALARM STORAGE CABINET <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE n ACCEPTABILITY J.SHELDON 05 0s 24 FIRE ALARM SYSTEM DETAILS A 05/09/24 <br /> A FIRE ALARM PANEL INSTALLATION 34558629 AGOW JS AGOW KM 05 09 24 THIS DESIGN AND/OR CHECKED <br /> / / / / m SPECIFICATION IS APPROVED K. MULLEN 05 10 24 SHEET <br /> IN <br /> BOE//VG® APPROVED BY DEPT. DATE KN MULLEN DS 1D 24 TITLE E506 \ <br /> CHECKED <br /> LOT W2 BUILDINGS 7-581 7-582 & 7-584 APPROVED , JOB N0. COMP N0. <br /> 34558629 <br /> t_9 APPROVED MDK EVERETT, WA DWG No. FA-W2-7-582 <br />