Laserfiche WebLink
2.3.3 Control LEDs <br /> The control LEDs can give you information about the status of the device. <br /> 01) (40 1) Pump is working <br /> 2) Pump is at 100% <br /> 3) Pump Error <br /> 02) (50 4) Battery <br /> 5) Radio signal <br /> 03) (60 6) DMX <br /> 2.3.3.1 Pump is working <br /> This LED tells you if the pump is working. It should only be lit in Armed-Mode, not in Test-Mode. <br /> 2.3.3.2 Pump is at 100% <br /> This LED shows if the pump has reached the necessary pressure. <br /> 2.3.3.3 Pump Error <br /> This LED shows if there is an error at the pump. If this LED is lit, it may indicate an empty Liquid- <br /> canister. You may not use the Wave-Flamer if this LED is lit, since it may cause severe damage to the <br /> device. <br /> 2.3.3.4 Battery <br /> This LED indicates the Battery status. If it is continually alight, the voltage is okay. If it should start to <br /> flash, the device does not get enough power. If the device is powered by the 230V connection, and <br /> the LED starts to flash,this may indicate damage to one of the transformers. <br /> 2.3.3.5 Radio signal <br /> This LED flashes if the X2 Wave-Flamer receives a radio signal. <br /> 2.3.3.6 DMX <br /> If the device is fitted with DMX, and ready,this LED will be lit permanently. If the device receives <br /> DMX signals,the LED will flash for confirmation. <br /> 2.3.4 Status LED <br /> Optional Status LED. In the current version of the device, it is not used. <br /> 2.3.5 Programing socket <br /> This socket is used to program the device. <br /> 2.3.6 DMX-Connectors <br /> Optional connectors to control the device via DMX. <br /> 2.3.7 ON/OFF Switch <br /> ON/OFF Switch of the X2 Wave-Flamer.To activate,the "Start"-Button must also be pushed. <br />