FtENGINEERS <br /> PANELM4SEC 1 -EXISTING PANEL SCHEDULE PROJECT: CASCADEHSBLDG4-BOILER REPLACE PANEL W SEC 1 -REVISED PANEL SCHEDULE PROJECT: CASCADEHSBLDG4-BOILERREPLACE <br /> Seattle//Spokane//Baltimore <br /> 277/480V,3Ph,4W. 600A Bus M.L.O. 11-Sep-23 277/48OV,3Ph,4W. 600A Bus M.L.O. 11-Sep-23 Copyright© `Si consulting engineers <br /> Ckt. Description/ Load Load C.B. C.B. C.B. C.B. Load Load Description/ Ckt. Ckt. Description/ Load Load C.B. C.B. C.B. C.B. Load Load Description/ Ckt. <br /> No. Location (VA) Type Amp Pole Phase Amp Pole (VA) Type Location No. No. Location (VA) Type Amp Pole Phase Amp Pole (VA) Type Location No. <br /> 1 HP 401 727 M 20 3 A 20 3 381 M HP 402 2 1 HP 401 727 M 20 3 A 20 3 381 M HP 402 2 <br /> 3 - [7 HP] 727 M - - B - - 381 M - [7/2 HP] 4 3 - [1 HP] 727 M - - B - - 381 M - [1/2 HP] 4 Electrical Consultants,Inc. <br /> 5 - 727 M - - C - - 381 M - 6 5 - 727 M - - C - - 381 M - 6 19015 36th Avenue West,Suite E <br /> 7 HP 403 381 M 20 3 A 20 3 727 M HP 414 8 7 HP 403 381 M 20 3 A 20 3 727 M HP 414 8 Lynnwood,Washington 98036 <br /> 9 - [1/2 HP] 381 M B 727 M - [1 HP] 10 9 - [1/2 HP] 381 M B 727 M - It HP] 10 Phone(425)775-1799 FAX(425)774-9870 <br /> 11 - 381 M C 727 M - 12 11 - 381 M C 727 M - 12 <br /> 13 HP 404 727 M 20 3 A 20 3 381 M HP 410 14 13 HP 404 727 M 20 3 A 20 3 381 M HP 410 14 <br /> - - - - <br /> 15 - [1 HP] 727 M B 381 M - [1/2 HP] 16 15 - It HP] 727 M - - - - <br /> B 381 M - [1/2 HP] 16 <br /> 17 - 727 M C 381 M - 18 17 - 727 M C 381 M - 18 <br /> 19 HP 407 381 M 20 3 A E2O <br /> 3 381 M HP 428 20 19 HP 407 381 M 20 3 A 20 3 381 M HP 426 20 <br /> 21 - [1/2 HP] 381 M B 381 M - [1/2 HP] 22 21 - [1/2 HP] 381 M B 381 M - [1/2 HP] 22 <br /> 23 - 381 M C 381 M - 24 23 - 381 M C 381 M - 24 <br /> 25 HP 408 381 M 20 3 A 3 727 M HP 412 26 25 HP 408 381 M 20 3 A 20 3 727 M HP 412 26 <br /> 27 - [1/2 HP] 381 M B 727 M - [1 HP] 28 27 - [1/2 HP] 381 M B 727 M - It HP] 28 <br /> 29 - 381 M C 727 M - 30 29 - 361 M C 727 M - 30 <br /> 31 HP 406 381 M 20 3 A 3 727 M HP 409 32 31 HP 406 381 M 20 3 A 20 3 727 M HP 409 32 <br /> 33 - [1/2 HP] 381 M B 727 M - [1 HP] 34 33 - [1/2 HP] 361 M B 727 M - It HP] 34 <br /> 35 - 381 M C 727 M - 36 35 - 361 M C 727 M - 36 <br /> 37 HP 413 381 M Y. 3 A SPARE 36 37 HP 413 381 M 20 3 A SPARE 38 <br /> 39 - [1/2 HP] 381 M B SPARE 40 39 - [1/2 HP] 381 M B SPARE 40 <br /> 41 - 381 M - - C SPARE 42 41 - 381 M - - C I i i 1SPARE 42 7 <br /> Total Connected Load: Ph A 6,683 VA 24 A Total Connected Load: Ph A 6,683 VA 24 A LI 1 I <br /> Total Connected Load: Ph B 8,883 VA 24 A Total Connected Load: Ph B 6,683 VA 24 A L.IJ <br /> Total Connected Load: Ph C 6,683 VA 24 A Total Connected Load: Ph C 6,683 VA 24 A <br /> Total Connected Load: 20.0 KVA Total Demand Load: 39.9 KVA Total Connected Load: 20.0 KVA Total Demand Load: 20.0 KVA <br /> 24.1 AMPS 48.0 AMPS 24.1 AMPS 24.1 AMPS w <br /> U <br /> Connected Subfed Total Demand Demand Accessones: Connected Subfed Total Demand Demand Accessories: <br /> Loads Loads(S) Loads Factor Load Loads Loads(S) Loads Factor Load <br /> G General(Nor-Continuous) 0 0 0 100% 0 G General(Nor-Continuous) 0 0 0 100% 0 J <br /> L Lighting 0 0 0 125% 0 L Lighting 0 0 0 125% 0 <br /> R Receptacles-to 10 KVA 0 0 0 100% 0 R Receptacles-to 10 KVA 0 0 0 100% 0 <br /> over 10 KVA 0 0 50% 0 -10 KVA 0 0 50% 0 <br /> K Kitchen 0 0 0 65% 0 K Kitchen 0 0 0 65% 0 <br /> H Heating 0 0 0 100% 0 H Heating 0 0 0 100% 0 <br /> M Motors 20,048 19,840 39,888 100% 39,888 M Motors 20,048 0 20,048 100% 20,048 Z <br /> LM Largest Motor 0 0 0 125% 0 LM Largest Motor 0 0 0 125% 0 O <br /> WH Water Heater 0 0 0 125% 0 WH Water Heater 0 0 0 125% 0 <br /> C Continuous General Load 0 0 0 125% 0 C Continuous General Load 0 0 0 125% 0 �r� <br /> 20,048 VA 19,840 VA 39,888 VA 39,888 VA 20,048 VA 0 VA 20,048 VA 20,048 VA 1 V <br /> J J Z <br /> p m cn <br /> PANEL M4 SEC 3-EXISTING PANEL SCHEDULE PROJECT: CASCADE HSBLDG4-BOILER REPLACE PANEL M4 SEC 3-REVISED PANEL SCHEDULE PROJECT: CASCADE HSBLDG4-BOILER REPLACE = l <br /> 277/480V,3Ph,4W. 600A Bus M.L.O. 11-Sep-23 277/480V,3Ph,4W. 600A Bus MLO. 11-Sep-23U ^ <br /> Ckt. Description/ Load Load C.B. C.B. C.B. C.B. Load Load Description/ Ckt. Ckt. Description/ Load Load C.B. C.B. C.B. C.B. Load Load Description/ Ckt. co <br /> No. Location (VA) Type Amp Pole Phase Amp Pole (VA) Type Location No. No. Location (VA) Type Amp Pole Phase Amp Pole (VA) Type Location No. <br /> 31 CWP401 3,809 M 30 3 A 40 3 7,271 M FC401 PRIMARY PUMP 32 85 CWP401 2,200 M 30 3 A 40 3 7,271 M FC401 PRIMARY PUMP 86 U (D LLI <br /> 33 - [7.5 HP] 3,809 M - - B - - 7,271 M - [15 HP] 34 87 - [7.5 HP] 2,200 M - - B - - 7,271 M - [15 HP] 88 Z n/ <br /> 35 - 3,809 M - - C - - 7,271 M - 36 89 - 2,200 M - - C - - 7,271 M - 90 LL <br /> 37 CWP402 3,809 M 30 3 A 20 3 2,632 M FC401 PONY PUMP 38 91 CWP402 2,200 M 30 3 A 20 3 2,632 M FC401 PONY PUMP 92 M LU <br /> 39 - [7.5 HP] 3,809 M - - B - - 2,632 M - [5 HP] 40 93 - [7.5 HP] 2,200 M - - B - - 2,632 M - [5 HP] 94 W Q > <br /> 41 - 3,809 M - - C - - 2,632 M - 42 95 - 2,200 M - - C - - 2,632 M - 96 1 LLI <br /> 43 MUA 402 554 M 20 3 A 20 3 727 M FC401 SUMP PUMP 44 97 MUA 402 554 M 20 3 A 20 3 727 M FC-401 SUMP PUMP 98 J <br /> 45 - [1.5 HP 554 M - - B - - 727 M - [1 HP] 48 99 - [1.5 HP 554 M - - B - <br /> 47 - 554 M - - C - - 727 M - 48 101 - 554 M - - C - - 727 M - 102 <br /> 49 MUA 401 1,039 M 20 3 A 20 3 1,333 H FC401 SUMP HEATER 50 103 MUA 401 1,039 M 1 20 1 3 A 20 3 1,333 H FC401 SUMP HEATER 104 <br /> 51 - [3/4 HP] 1,039 M - - B - - 1,333 H - [4KW] 52 105 - [3/4 HP] 1,039 M - - B - - 1,333 H - [4KW] 106 <br /> 53 - 1,039 M - - C - - 1,333 H - 54 107 - 1,039 M - - C - - 1,333 H - 108 O <br /> 55 HP418 623 M 20 3 A 20 3 1,800 M AIR 401,HP4-07 56 109 HP418 623 M 20 3 A 20 3 1,800 M AIR 401,HP4-07 110 'I I J <br /> 57 - 623 M - - B - - 1,800 M - 58 111 - 623 M - - B - - 1,800 M - 112 •' ' O Z <br /> 59 - 623 M - - C - - 1,800 M - 60 113 - 623 M - - C - - 1,800 M - 114 <br /> 61 ISPACE I A 20 3 900 M HP424 62 115 SPACE A 20 3 900 M HP424 116 W O Q <br /> 83 SPACE B - - 900 M - 64 117 SPACE B - - 900 M - 118 <br /> 65 SPACE I C 900 M - 66 119 SPACE C - 900 M - 120 \ <br /> 67 XFMR TMP4 4,383 SL 70 3 A SPACE 68 121 XFMR TMP4 5,703 SL 70 3 A SPACE 122 / 1 V <br /> 69 - 9,025 SL - - B SPACE 70 123 - 10,345 SL - - B SPACE 124 W ( l w <br /> 71 - 2,925 SL - - C SPACE 72 125 - 2,925 SL - - C SPACE 126 �/ <br /> Total Connected Load: Ph A 28,880 VA 104 A Total Connected Load: Ph A 26,982 VA 97 A <br /> Total Connected Load: Ph B 33,522 VA 121 A Total Connected Load: Ph B 31,625 VA 114 A T C) <br /> Total Connected Load: Ph C 27,422 VA 99 A Total Connected Load: Ph C 24,204 VA 87 A y <br /> 00 <br /> Total Connected Load: 89.8 KVA Total Demand Load: 73.5 KVA Total Connected Load: 82.8 KVA Total Demand Load: 63S KVA 11 <br /> 108.0 AMPS 88.4 AMPS 99.6 AMPS 76.8 AMPS 0 <br /> y <br /> Connected Subfed Total Demand Demand Accessories: Connected Subfed Total Demand Demand Accessories: <br /> Loads Lcads(S) Loads Factor Load Loads Loads(S) Loads Factor Load 1 1 <br /> G General(Non-Continuous) 0 0 0 100% 0 G General(Non-Continuous) 0 0 0 100% 0 UJ <br /> L Lighting 0 0 0 125% 0 L Lighting 0 0 0 125% 0 Q <br /> R Receptacles-to 10KVA 0 0 0 100% 0 R Receptacles-to10KVA 0 0 0 100% 0 Q <br /> ver 10 KVA 0 0 50% 0 oeer 10 KVA 0 0 50% 0 <br /> K Kbchen 0 0 0 65% 0 K Kitchen 0 0 0 65% 0 ' <br /> H Heating 4,000 0 4,000 100% 4,000 H Heating 4,000 0 4,000 100% 4,000 V <br /> M Motors 69,490 0 69,490 100% 69,490 M Motors 59,838 0 59,838 100% 59,838 '^ <br /> LM Largest Motor 0 0 0 125% 0 LM Largest Motor 0 0 0 125% 0 <br /> WH Water Heater 0 0 0 125% 0 Vdi Water Heater 0 0 0 125% 0 C Continuous General Load 0 0 0 125% 0 C Continuous General Load 0 0 0 125% 0 < <br /> 73,490 VA 0 VA 73,490 VA 73,490 VA 63,838 VA 0 VA 63,838 VA 63,838 VA ( 1 <br /> PANEL MP4SEC 1 -EXISTING PANEL SCHEDULE PROJECT: CASCADE HSBLDG4-BOILER REPLACE PANEL MP4SEC 1 -REVISED PANEL SCHEDULE JPRCl CASCADE IF,BLDG4-BOILER REPLACE <br /> 120/208V,3Ph,4W. 400A Bus M.L.O. 11-Sep-23 120/208V,3Ph,4W. 400A Bus MLLO. 11-Sep-23 <br /> Ckt. Description/ Load Load C.B. C.B. C.B. C.B. Load Load Description/ Ckt. Ckt. Description/ Load Load C.B. C.B. C.B. C.B. Load Load Description/ Ckt. <br /> No. Location (VA) Type Amp Pole Phase Amp Pole (VA) Type Location No. No. Location (VA) Type Amp Pole Phase Amp Pole (VA) Type Location No. <br /> 1 HP4-31 1,175 M 20 2 A 20 2 1,175 M HP4-19 2 1 HP4-31 1,175 M 20 2 A 20 2 1,175 M HP4-19 2 <br /> 3 1,175 M B 1,175 M - 4 3 1,175 M B 1,175 M - 4 <br /> 5 SPARE 20 1 C 20 1 SPARE 6 5 SPARE 20 1 C 20 1 SPARE 6 ,�Y .�•A,. <br /> 7 SPARE 20 1 A 20 1 SPARE 8 7 SPARE 20 1 A 20 1 SPARE 8 C <br /> 9 HP4-05 915 M 20 2 B 20 1 SPARE 10 9 HP4-05 915 M 20 2 B 20 1 SPARE 10 <br /> 11 - 915 M - - C 20 1 SPARE 12 11 - 915 M - - C 20 1 SPARE 12 <br /> 13 EMS 480 C 20 1 A 20 1 1,000 R REC-ROOF,PENTHOUSE 14 13 BIAS 480 C 20 1 A 20 1 1,000 R REC-ROOF,PENTHOUSE 14 <br /> 15 CHEM-401 1,440 C 20 1 B 20 1 1,000 R REC-ROOF,PENTHOUSE 16 15 CHEMA01 1,440 C 20 1 B 20 1 1,000 R REC-ROOF,PENTHOUSE 16 <br /> 17 EMS 20 1 C 20 1 1,000 R REC-ROOF,PENTHOUSE 18 17 EMS 20 1 C 20 1 1,000 R REC-ROOF,PENTHOUSE 18 44h1419 <br /> 19 REC-F.C. 20 1 A 20 1 73 M HWC-401 20 19 REC-F.C. 20 1 A 20 1 73 M HWC401 20 <br /> a <br /> 21 HT401 2,000 C 20 1 B 20 1 1 840 I M IWH401 1 22 21 IHT401 1 21000 C 20 1 B 20 1WH-001 22 <br /> 23 SOL401 240 C 20 1 C 20 1 HOIST 24 23 SOL-001 240 C 20 1 C 20 1 HOIST 24 <br /> 25 SPARE 20 3 A 20 1 480 H B401 26 25 SPARE 20 3 A 120 <br /> 1 1,800 H B-001 26 <br /> 27 - - - B 20 1 480 H B402 28 27 - - - B 1 1,800 H B-402 28 Project No. <br /> 29 - C 20 1 770 EF410 30 29 - C J 1 770 EF410 30 <br /> 23025 <br /> Total Connected Load: Ph A 4,383 VA 37 A Total Connected Load: Ph A 5,703 VA 48 A <br /> Total Connected Load: Ph B 9,025 VA 75 A Total Connected Load: Ph B 10,345 VA 86 A Date <br /> Total Connected Load: Ph C 2,925 VA 24 A Total Connected Load: Ph C 2,925 VA 24 A <br /> Total Connected Load: 16.3 KVA Total Demand Load: 27.4 KVA Total Connected Load: 19.0 KVA Total Demand Load: 30.1 KVA 09.11.2023 <br /> 45.4 AMPS 76.2 AMPS 52.7 AMPS 83.5 AMPS <br /> Date Revision <br /> Connected Subfed Total Demand Demand Accessories: Connected Subfed Total Demand Demand Accessories: <br /> Loads Loads(S) Loads Factor Load Loads Loads(S) Loads Factor Load <br /> G General(Non-Continuous) 0 400 400 100% 400 G General(Non-Continuous) 0 400 400 100% 400 <br /> L Lighting 0 0 0 125% 0 L Lighting 0 0 0 125% 0 <br /> R Receptacles-to 10 KVA 3,000 0 3,000 100% 3,000 R Receptacles-to 10 KVA 3,000 0 3,000 100% 3,000 <br /> over 10 KVA 0 0 50% 0 over 10 KVA 0 0 50% 0 <br /> K Kitchen 0 0 0 65% 0 K Kitchen 0 0 0 65% 0 Sheet Title <br /> H Heating 960 0 960 100% 960 H Heating 3,600 0 3,600 100% 3,600 <br /> M Motors 7,444 7,479 14,923 100% 14,923 M Motors 7,444 7,479 14,923 100% 14,923 <br /> LM Largest Motor 0 0 0 125% 0 LM Largest Motor 0 0 0 125 <br /> % o PANEL SCHEDULES <br /> WH Water Heater 0 0 0 125% 0 WH Water Heater 0 0 0 125% 0 <br /> C Continuous General Load 4,160 2,352 6,512 125% 8,140 C Continuous General Load 4,160 2,352 6,512 125% 8,140 <br /> 15,564 VA 10,231 VA 25,795 VA 27,423 VA 18,204 VA 10,231 VA 28,435 VA 30,063 VA <br /> Sheet <br /> PERMIT SET EO . <br /> 1 <br /> I <br />