My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3625 BROADWAY SONIS KITCHEN 2025-01-03
>
Address Records
>
BROADWAY
>
3625
>
SONIS KITCHEN
>
3625 BROADWAY SONIS KITCHEN 2025-01-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2025 2:17:52 PM
Creation date
12/8/2024 9:47:38 AM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
3625
Tenant Name
SONIS KITCHEN
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
132
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL CONSTRUCTION NOTES <br /> 1. The General Contractor shall provide building penetrations, roofing, and other IMC 2018 SECTION 507.1.1 ❑PERATION. (PARTIAL) <br /> construction needs for installation of system equipment. THE EXHAUST FAN SERVING A TYPE I HOOD SHALL HAVE AUTOMATIC CONTROLS THAT <br /> WILL ACTIVATE THE FAN WHEN ANY APPLIANCE THAT REQUIRES SUCH TYPE I HOOD <br /> 2. The General Contractor shall be responsible for Maintaining structural integrity and IS TURNED ON, OR A MEANS OF INTERLOCK SHALL BE PROVIDED THAT WILL PREVENT <br /> provide required structural supports as required City of Everett. OPERATION OF SUCH APPLIANCES WHEN THE IS NOT TURNED ON.. <br /> 3. The General Contractor shall be responsible for other trades unless otherwise stated <br /> by the conditions of the general contract with the project owner. TYPE I EXHAUST AIR DUCTWORK TO BE MAKE-UP AIR DUCTWORK TO BE <br /> FULLY WELDED 16 GAUGE STEEL FULLY SEALED 22 GAUGE STEEL <br /> EXHAUST SYSTEM NOTES REVISIONS: <br /> DUCTWORK TO BE CONTINUOUS INTERNAL MAKE-UP AIR DUCTWORK TO BE INSULATED <br /> 1. The exhaust/make-up air systems are to meet requirements of the International Mechanical Code, OR EXTERNAL LIQUID-TIGHT WELDED <br /> and NFPA-96. The Type I exhaust ductwork to be constructed of fully welded 16 gauge steel. SMOOTH, ACCESSIBLE FOR INSPECTION, <br /> AND WITHOUT GREASE TRAPS <br /> 2. Exhaust must be a minimum of 10'-0' from any air intake, adjacent building, or adjoining property. <br /> 3. Exhaust and make-up air systems must be electrically interconnected to be operated <br /> simultaneously by a single on/off switch. <br /> ELECTRICAL NOTES <br /> FAN BASE <br /> 1. The electrical contractor shall provide and Install Interconnecting field wiring between the <br /> z hood equipment control switches, and exhaust / make-up air system equipment contactors. <br /> 2. The electrical contractor shall install exhaust fan and make-up air system motor relays <br /> a and disconnect switches. <br /> w 3. The electrical contractor shall verify proper fan motor rotation, <br /> cai TYPICAL HINGE KIT <br /> a EQUIPMENT CURB <br /> z EF-1 TYPE I EF-1 TYPE I <br /> 0 EXHAUST FAN 120" EXHAUST FAN J O <br /> MUA-1 MAKE-UP MUA-1 MAKE-UP > <br /> AIR FAN AIR FAN w Q <br /> 00 <br /> 5 _ � <br /> o ra Q <br /> 3 439. 439, <br /> 0 16 16 / MUA-1 MAKE-UP \ I--I <br /> AIR UNIT ON ROOF (o <br /> z 18" 18' o <br /> ate-+ <br /> a L <br /> m <br /> Ln <br /> m / EF-1 TYPE I O (1J L J <br /> EXHAUST FAN EH-1 TYPE I <br /> CLEAN-OUT w (n LD <br /> > ACCESS I ON ROOF EXHAUST HOOD <br /> CLEAN-OUT / <br /> FIRE RATED 10'-0' <br /> ❑14'x14" SLOPE DUCT ❑ ACCESS 16'x16' 14"x14' / DUCT WRAP MINIMUM TO <br /> J i ANY AIR INTAKE <br /> F FIRE RATED Li <br /> DUCT WRAP <br /> 0 16'x16'019'-6' °�' <br /> ABOVE r-1 <br /> GROUND <br /> o 18" <br /> LEVEL <br /> o _ / ^. <br /> ro <br /> N <br /> 24"ZVV EH-1 TYPE I <br /> EXHAUST HOOD — Q <br /> 3+ 6" EH-1 TYPE I 6" 3' o <br /> a <br /> EXHAUST HOOD 18' 18" 51' N o <br /> ONE HOUR FIRE 52" 2 r co <br /> RATED WALL PAD 44' a <br /> COOKING 6' w <br /> EQUIPMENT MIN z UD <br /> 80' I F `o co <br /> 00 00 00 00 0o ONE HOUR o o U'� <br /> FIRE RATED CO <br /> WALL PAD c <br /> U O <br /> < co P <br /> DRAWN BY: DOUG WALTER <br /> UPDATE: 04/11/2024 <br /> ELEVATION <br /> 0 <br /> Scale 3/8"= 1'-0" TITLE: <br /> COMMERCIAL KITCHEN <br /> EXHAUST SYSTEM <br /> TYPE I EXHAUST AND MAKE-UP AIR SYSTEM EQUIPMENT SCHEDULE <br /> PLAN VIEW NORTH <br /> City of Everett Permit Review J.H11T1YZPr= <br /> M HOOD CAPTURE SIZE HOOD EXHAUST EXHAUST EXHAUST EXHAUST EXHAUST FAN MAKE-UP MAKE-UP MAKE-UP MAKE-UP MAKE-UP AIR FAN SHEET <br /> WEIGHT DUCT DUCT AIR DUCT DUCT AIR DUCT DUCT <br /> EVERETT Status:Reviewed TOT Permit WITH SIZE WEIGHT CFM VELOCITY FAN MAKE MODEL CFM HP ESP POWER RPM FAN SQE CFM VELOCITY WEK#iT FAN MAKE MODEL HP ESP PO RPM MBTU'S UNIT C� <br /> 04/16/2024 9:28:58 AM WITH <br /> WEIGHT WEIGHT Scale 1/4"— 1'-0" M—2 <br /> 8'-a'X 4'-6'CANOPY GREASE HOOD ZI 1SS 14'x14' 185 LBS 2000 CFM 1471 FPM EF-1 ACCUREX XRUD-140-VG 2000 1.0 1.448 115/1 1688196 LBS IV.16' 1800 CFM 1017 RPM 200 LSS MUA-1 ACCUREX XDGX-PBS-H05-VFD 1 1.5 1AW 208/3 1002 85.5 398 LR3 �D I <br />
The URL can be used to link to this page
Your browser does not support the video tag.