My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3625 BROADWAY SONIS KITCHEN 2025-01-03
>
Address Records
>
BROADWAY
>
3625
>
SONIS KITCHEN
>
3625 BROADWAY SONIS KITCHEN 2025-01-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2025 2:17:52 PM
Creation date
12/8/2024 9:47:38 AM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
3625
Tenant Name
SONIS KITCHEN
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
132
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
R-102 Restaurant Fire Suppression Mantra! SECTION 4—SYSTEM DESIGN <br /> UL EX3470 ULC EX3470 <br /> 2014-SEP-01 REV.11 PAGE 4-75 <br /> ELECTRICAL GAS VALVE REQUIREMENTS(Continued) ELECTRICAL SWITCH REQUIREMENTS <br /> Approvals' Note:Electrical connections shall not be made In the <br /> ANSUL gas valves listed In this section are UL listed and AUTOMAN. <br /> approved for 110 VAC.If more information Is required,refer to The electric(snap-action)switches for the R-102 system are <br /> the Gas and Oil Equipment List of Underwriters Laboratories, specially designed to fit the regulated release assembly.The <br /> Inc.under"Electrically Operated Valves Guide No.440 AS'or .switches are intended for use with electric gas valves,alarms, <br /> consult Tyco Fire Protection Products, Marinette,1Msconsin contactors, lights,contractor suppiled electric power shut-of <br /> i 54143-2542. devices,and other electrical devices that are designed to shut <br /> i off or turn on when the fire suppression system is actuated. <br /> II other gas valves are used,they shall be*UL listed electrical- <br /> (See Figures 5.122 through 5-124 in Installation Section for <br /> ty-operated safety valves for natural or LP gas as required,of reference). <br /> appropriate pressure and temperature rating,110 VAC160 Hz.' <br /> The information on temperature and type of gas that the valves Contractors shall supply'UL Hated,enclosed industrial control <br />! are suitable for may be found In the Gas and Oil Equipment List equipment or magnetic switch having a rating matching that of <br /> of Underwrlers Laboratories,Inc.under"Electrically Operated the cooking appliance,call 110 VAC160 Hz or 24 VAC160 Hz." <br /> Valves Guide No.440 A5." AN electrical connections should be performed by a QUALIFIED <br /> The electrically operated gas valve must be of the type that ELECTRICIAN and in accordance with authority having <br /> needs to be energized to remain open. jurisdiction. <br /> I Note:For electrical wiring diagrams,see"Installation Instructions" Electric(Strap-Action)Switches thief may be field installed are: <br /> Section,Pages 5-40 through 5-42. Part No, Description <br /> Parts that may he used for Installation of a 110 VAC Gas Shut- 423878 One Switch Kit <br /> off Valve are: 423879 Two Switch Kit <br /> Description Part No. 423880 Three Switch Kit . <br /> Electric Solenoid Valve,314 in.NPT' 13707 423881 Four Switch Kit <br /> Electric Solenoid Valve,1 in.NPT' 13708 436770 Two Switch Kit(no wire leads) <br /> .Electric Solenoid Valve,1 114 In.NPT' 550360 Each switch has a set of single-pole,double throw contacts <br /> Electric Solenoid Valve,1 1YJ in.NPT' 13709 rated at 21 arnp,1 HP,125,250,277 VAC or 2 HP,250,277 <br />! Electric Solenoid Valve,2 In.NPT' 13710 VAC. <br /> Electric Solenoid Valve,2 112 in.NPT' 550363 We:A relay must he supplied by others if the equipment load <br /> Elecldc Solenoid Valve,3 In.NPT` 17643 exceeds the rated capacity of the switch. <br /> Manual Reset Relay(110 VAC) 426151 Electrical wiring and equipment shalt be Installed in accordance <br /> •w+w...„o,"any ao.�a wna„ada�raroa_ with NFPA 70(National Flecldcal Code)or the requirements of <br /> the authority having jurisdiction <br /> ALARM INITIATING SWITCH REQUIREMENTS The Alarm Initiating Switch can be field mounted within the s a lire alarm system t provided,the fire extinguishing system <br /> AUTOMAN release.1 he switch must be used to dose a super- shall be eats of connected to the alarm system in Alarm <br /> C accordance s with the <br /> vised alarm circuit to the building math flre alarm panel when actuation <br /> a NFPA ish National Fire Alarm Code,so lard the <br /> the AUTOMAN release actuates.This action will signal the(ire actuation of the the extinguishing system will soul the fire alarm as <br /> alarm panel that there was a system actuation In the kitchen well as provide the extinguishing:unction of the system. <br /> area.The switch kit contains all necessary mounting compo- If supervision of the electrical defection,electrical actuation or <br /> nents along with a mounting instruction sheet.See Page 5.39 electrical power supply circuit is provided,it shall give prompt <br /> for wiring information. audible or visual indication of trouble and shall be distinctive <br /> The switch is rated 50 mA,28VDC. from alarms at indicators indicating operation or hazardous <br /> conditionsas specified in NFPA 17A. <br /> Part No. Description <br /> 428311 Alarm Initiating Switch Kit <br /> I <br /> i <br /> i <br />
The URL can be used to link to this page
Your browser does not support the video tag.