Laserfiche WebLink
Seismic Requirements (IBC 1704.3.2) <br /> Describe the seismic force resisting system and designated seismic systems subject to special inspections in <br /> accordance with IBC 1705.13 or 1705.14 <br /> The vehicle lifts will be anchored to the concrete(either existing or new)via post-installed anchors(expansion or adhesive).The <br /> seismic design is limited to the anchorage to concrete and does not include the strength of the lifts themselves. <br /> The extent of seismic force resisting system and designated seismic systems are defined in more details in the construction documents. <br /> Wind Requirements (IBC 1704.3.3) <br /> Describe the wind force resisting systems and wind resisting components subject to special inspections in accordance <br /> with IBC 1705.12 <br /> The vehicle lifts will be installed in the interior of the building,and therefore,are not subject to wind loading. <br /> The extent of wind force resisting system is defined in more details in the construction documents. <br /> Structural Observation (IBC 1704.6) <br /> Describe frequency and extent of structural observations when required by the provisions of IBC 1704.6.1 <br /> Structural observations are not required for this project. <br /> The extent of structural observation is defined in more details in the construction documents. <br /> GENERAL INFORMATION: <br /> Page 5 of 8 <br /> •Obtain a building permit before starting construction. <br /> •This construction bulletin is intended to provide guidelines and a checklist of some special inspections that may be required per 2021 IBC. <br />