My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10521 19TH AVE SE EDWARD JONES 2025-10-27
>
Address Records
>
19TH AVE SE
>
10521
>
EDWARD JONES
>
10521 19TH AVE SE EDWARD JONES 2025-10-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/27/2025 9:17:17 AM
Creation date
12/12/2024 10:10:31 AM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
10521
Tenant Name
EDWARD JONES
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
254
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Fan -Coil Unit Test Data <br />Project No. <br />2024-1113 <br />Project I.D. <br />Edward Jones Branch # 98316 <br />Test Date <br />9/16/2024 <br />Tested By <br />Vinh Nguyen <br />Area Served <br />Branch Support, Offices, Equip/Supply <br />Equipment I.D. <br />FCU-2 <br />Unit Information <br />Manufacturer <br />Carrier <br />Model Number <br />40VMM030A--3 <br />Serial Number <br />1324VO0477 <br />Unit Location <br />Office 102 E <br />Supply Fan Quantity / Rotation <br />N/A / Correct <br />Supply Fan Drive Type <br />Direct Drive <br />Unit Filter Information <br />Filter I.D. <br />Type <br />Rating <br />Filter Size / Quantity <br />Filter Size / Quantity <br />Unit Filter <br />Pleated <br />N/A <br />11X43X2" / 1 <br />N/A / <br />Unit and Fan Test Data <br />Total Design Airflow <br />1,070 CFM <br />Total Actual Airflow <br />1,015 CFM <br />Design Return Airflow <br />1,070 CFM <br />Actual Return Airflow <br />860 CFM <br />Min OSA CFM Des / Act <br />155 CFM / 165 CFM <br />Min OSA Position OSA / RA <br />N/A / #VALUE! <br />Design ESP <br />0.50 in.wc <br />Actual ESP <br />0.27 in.wc <br />Actual Volts <br />207 <br />Actual Amps <br />1.04 <br />Fan Speed Setting <br />Med-High <br />Additional Settings <br />N/A <br />Unit Motor Information <br />HP / RPM <br />1/3 / <br />Motor Phase / Hz <br />1 / 60 <br />Motor Rated Volts / FLA <br />208-230 / 2.5 <br />1Motor Eff. / PF <br />/ - <br />Unit Pressure Data <br />Filter In / Out <br />-0.170 in.wc / -0.320 in.wc <br />Filter AID <br />0.150 in.wc <br />Supply Fan In / Out <br />- in.wc / 0.100 in.wc <br />Supply Fan A P <br />#VALUE! in.wc <br />External Static In / Out <br />-0.170 in.wc / 0.100 in.wc <br />External Static A P <br />0.270 in.wc <br />Unit Test Notes <br />Note (1) 1Thermostat fanspeed was set at Medium -High speed. <br />Page 13 of 49 <br />
The URL can be used to link to this page
Your browser does not support the video tag.