My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10521 19TH AVE SE EDWARD JONES 2025-10-27
>
Address Records
>
19TH AVE SE
>
10521
>
EDWARD JONES
>
10521 19TH AVE SE EDWARD JONES 2025-10-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/27/2025 9:17:17 AM
Creation date
12/12/2024 10:10:31 AM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
10521
Tenant Name
EDWARD JONES
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
254
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IMC 2018 VENTILATION RATE PROCEDURE CALCULATIONSc LAWRENCE <br />��``11��`` GROUP <br />OCCUPANT OCCUPANT BREATHING TABLE6-2ZONE TOTAL SUPPLY SYSTEM <br />AIR AIRTOZONEAT ZONE VENTILATION MINIMUM MINIMUM St. LOUTS <br />OUTDOOR AREA DENSITY OVER -VENTILATION ZONE 319 North 4th Street <br />UNIT FLOOR ROOM ROOM NAME ZONE TYPE AREA AIRFLOW OUTDOOR PEOPLE OCCUPANT PERCENTAGE OUTDOOR DISTRIBUTION CONDITION VENTILATION EFFICIENCY PERCENTAGE OUTSIDEAIRFLOW Suite 1000 <br />NUMBER SO FT RATE AIRFLOW RATE PER 1000 QUANTITY AIRFLOW RATE EFFECTIVENESS ANALYZED EFFICIENCY NOTE 2 AIRFLOW AT AT UNIT St. LOUTS, Missouri 63102 <br />(314)231-5700 <br />CFM/PER CFM/SO FT SO FT CFM (Ez) CFM - NOTE 1 (Evz) (Ev) UNIT NOTE 3 <br />FCU - 1 1st 107 BREAK Break rooms 155 5.0 0.06 25 4 0% 29 0.8 640 0.99 0.83 - - pmj¢u Team <br />1st 106C SMALL CONFERENCE Conference/meeting 84 5.0 0.06 50 4 0% 26 0.8 180 0.87 0.83 _ _ GENERAL CONTRACTOR: <br />To Be Determined <br />1st 106D SMALL CONFERENCE Conference/meeting 81 5.0 0.06 50 4 0% 25 0.8 140 0.83 0.83 - - <br />1st 103 PASSAGE Condors 166 0.0 0.06 0 0 0% 10 0.8 840 1.04 0.83 - - <br />FCU-1 TOTALS 1800 0.83 6% 109 <br />SPECIFIC NOTES: <br />PROFESSIONAL ENGINEER: <br />1. TOTAL SUPPLY AIR AT CONDITION ANALYZED USES THE MAXIMUM AIRFLOW PROVIDED TO THE ZONE DURING THE HEATING OR COOLING MODE, WHICHEVER IS BEING ANALYZED. NMEG <br />2. SYSTEM VENTILATION EFFICIENCY IS EQUAL TO THE LOWEST ZONE VENTILATION EFFICIENCY OF ALL ROOMS SERVED BY THE UNIT. Unit Outside Airflow Balance Setpoint [cfm] 110 'C <br />3. SEE UNIT EQUIPMENT SCHEDULE FOR ACTUAL OUTSIDE AIR SETPOINT FOR BALANCING; WHICH WILL MEET OR EXCEED THE MINIMUM REQUIREMENT NOTED HEREIN. Unit Meets ASHRAE 62.1 Requirements Yes <br />MEG <br />7600 E Orchard Road, Suite 250-S <br />Greenwood Village, CO 80111 <br />Phone: 303.796.6000 <br />IMC 2018 VENTILATION RATE PROCEDURE CALCULATIONS IMEG Project No: 24000280.07 <br />OCCUPANT OCCUPANT BREATHING TABLE6-2 ZONE <br />TOTAL SUPPLY SYSTEM Rmressl°rel sear. <br />OUTDOOR AREA DENSITY OVER -VENTILATION ZONE AIR AIRTOZONEAT ZONE VENTILATION MINIMUM MINIMUM <br />UNIT FLOOR ROOM ROOM NAME ZONE TYPE AREA AIRFLOW OUTDOOR PEOPLE OCCUPANT PERCENTAGE OUTDOOR DISTRIBUTION CONDITION VENTILATION EFFICIENCY PERCENTAGE OUTSIDEAIRFLOW <br />NUMBER SO FT RATE AIRFLOW RATE PER 1000 QUANTITY AIRFLOW RATE EFFECTIVENESS ANALYZED EFFICIENCY NOTE 2 AIRFLOW AT AT UNIT <br />CFM/PER CFM/SQ FT SO FT CFM (Ez) CFM - NOTE 1 (Evz) (Ev) UNIT NOTE 3 <br />FCU-2 106A BRANCH SUPPORT Office space 224 5.0 0.06 5 1 0% 19 0.8 175 0.99 0.89 - - <br />102A OFFICE Office space 64 5.0 0.06 5 1 0% 9 0.8 55 0.93 0.89 - - <br />102B OFFICE Office space 64 5.0 0.06 5 1 0% 9 0.8 55 0.93 0.89 - - <br />102C OFFICE Office space 64 5.0 0.06 5 1 0% 9 0.8 55 0.93 0.89 - - <br />102D OFFICE Office space 64 5.0 0.06 5 1 0% 9 0.8 55 0.93 0.89 - - <br />102E OFFICE Office space 64 5.0 0.06 5 1 0% 9 0.8 55 0.93 0.89 - - <br />102F OFFICE Office space 64 5.0 0.06 5 1 0% 9 0.8 55 0.93 0.89 - - <br />Pmjed Title'. <br />101E BRANCH SUPPORT Office space 190 5.0 0.06 5 1 0% 16 0.8 155 1.00 0.89 - - oc, <br />0 <br />103 PASSAGE Corridors 434 0.0 0.06 0 0 0% 26 0.8 235 0.99 0.89 - - CO <br />104 EQUIP/SUPPLY Occupiable storage rooms for dry materials 85 5.0 0.06 2 0 0% 6 0.8 70 1.02 0.89 - - Q <br />108 STORAGE Storage rooms 78 0.0 0.12 0 0 0% 9 0.8 50 0.89 0.89 - - <br />N <br />109 LOUNGE Office space 68 5.0 0.06 5 0 0% 6 0.8 55 1.00 0.89 - - <br />W <br />FCU-2 TOTALS 1070 _ 0.89 14% 152 <br />SPECIFIC NOTES: /r� Q0 <br />1. TOTAL SUPPLYAIR AT CONDITION ANALYZED USES THE MAXIMUM AIRFLOW PROVIDED TO THE ZONE DURING THE HEATING OR COOLING MODE, WHICHEVER IS BEING ANALYZED. � / � <br />2. SYSTEM VENTILATION EFFICIENCY IS EQUAL TO THE LOWEST ZONE VENTILATION EFFICIENCY OF ALL ROOMS SERVED BY THE UNIT. Unit Outside Airflow Balance Setpoint [cfm] 155 V/� \� <br />3. SEE UNIT EQUIPMENT SCHEDULE FOR ACTUAL OUTSIDE AIR SETPOINT FOR BALANCING; WHICH WILL MEET OR EXCEED THE MINIMUM REQUIREMENT NOTED HEREIN. Unit Meets ASHRAE 62.1 Requirements Yes C:W <br />Tr/ <br />IMC 2018 VENTILATION RATE PROCEDURE CALCULATIONS O V <br />OCCUPANT OCCUPANT BREATHING TABLE6-2ZONE TOTAL SUPPLY SYSTEM <br />OUTDOOR AREA DENSITY OVER -VENTILATION ZONE AIR AIRTOZONEAT ZONE VENTILATION MINIMUM MINIMUM <br />UNIT <br />FLOOR ROOM ROOM NAME ZONE TYPE AREA AIRFLOW OUTDOOR PEOPLE OCCUPANT PERCENTAGE OUTDOOR DISTRIBUTION CONDITION VENTILATION EFFICIENCY PERCENTAGE OUTSIDEAIRFLOW <br />NUMBER SO FT RATE AIRFLOW RATE PER 1000 QUANTITY AIRFLOW RATE EFFECTIVENESS ANALYZED EFFICIENCY NOTE 2 AIRFLOW AT AT UNIT <br />W <br />CFM/PER CFM/SQ FT SO FT CFM (Ez) CFM - NOTE 1 (Evz) (Ev) UNIT NOTE 3 to <br />FCU - 3 106A MEDIUM CONFERENCE Conference/meeting 151 5.0 0.06 50 8 0% 47 0.1 350 0.91 0.91 <br />LL > <br />100 WELCOME Main entry lobbies 344 5.0 0.06 10 3 01 38 0.8 720 1.01 0.91 - - Q <br />O <br />FCU-3 TOTALS 1070 _ 0.91 9% 93 <br />SPECIFIC NOTES: m W MM W N <br />ra � � <br />1. TOTAL SUPPLYAIR AT CONDITION ANALYZED USES THE MAXIMUM AIRFLOW PROVIDED TO THE ZONE DURING THE HEATING OR COOLING MODE, WHICHEVER IS BEING ANALYZED. <br />2 2. SYSTEM VENTILATION EFFICIENCY IS EQUAL TO THE LOWEST ZONE VENTILATION EFFICIENCY OF ALL ROOMS SERVED BY THE UNIT. Unit Outside Airflow Balance Setpoint [cfm] 95 TN Professional An hhecrs seal eMd ro thls sheet <br />UI pp ies only to the material and it.... hown on this <br />Q sheet All drawing, instruments or other document¢ rot <br />3. SEE UNIT EQUIPMENT SCHEDULE FORACTUAL OUTSIDE AIR SETPOINT FOR BALANCING; WHICH WILL MEET OR EXCEEDTHE MINIMUM REQUIREMENT NOTED HEREIN. Unit Meets ASHRAE 62.1 Requirements Yes eAibWNthi.sealshall notbeconsideredprepared by <br />q mre .II -ct. and mif architect expressN disclaims any <br />and all nu, w b hi for such plans, drawings or <br />documents not exhibiting rhls seal. <br />W <br />NIMC 2018 VENTILATION RATE PROCEDURE CALCULATIONS This drawmgand d¢tnilson itare the sole property of the <br />arohin,d and may be used for this specific project only. <br />WI <br />It shall not be loaned, copied or reproduced, in whole or <br />TOTAL SUPPLY SYSTEM part. or fwany other purposeor project with -the <br />OCCUPANT OCCUPANT BREATHING TABLE 6-2 ZONE carmen consent of me ercnnect. <br />g AIR AIRTOZONEAT ZONE VENTILATION MINIMUM MINIMUM No. Description <br />OUTDOOR AREA DENSITY OVER -VENTILATION ZONE Date <br />FLOOR ROOM ROOM NAME ZONE TYPE AREA AIRFLOW PEOPLE OCCUPANT PERCENTAGE OUTDOOR DISTRIBUTION CONDITION VENTILATION EFFICIENCY PERCENTAGE OUTSIDEAIRFLOW <br />OUTDOOR UNIT <br />w NUMBER SO FT RATE AIRFLOW RATE PER 1000 QUANTITY AIRFLOW RATE EFFECTIVENESS ANALYZED EFFICIENCY NOTE 2 AIRFLOW AT AT UNIT <br />CFM/PER CFM/SO FT SO FT CFM (Ez) CFM - NOTE 1 (Evz) (Ev) UNIT NOTE 3 <br />FCU-4 106B LARGE CONFERENCE Conference/meeting 241 5.0 0.06 50 12 0% 75 0.8 430 0.96 0.96 - - <br />aSh-i, <br />m FCU-4 TOTALS 430 0.96 18% 78 SCHEDULES <br />MECHANICAL <br />SPECIFIC NOTES: SCHEDULE S <br />3 1. TOTAL SUPPLYAIR AT CONDITION ANALYZED USES THE MAXIMUM AIRFLOW PROVIDED TO THE ZONE DURING THE HEATING OR COOLING MODE, WHICHEVER IS BEING ANALYZED. <br />W Pml¢d Number'. Sheet Number'. <br />2. SYSTEM VENTILATION EFFICIENCY IS EQUAL TO THE LOWEST ZONE VENTILATION EFFICIENCY OF ALL ROOMS SERVED BY THE UNIT. Unit Outside Airflow Balance Setpoint [cfm] 80 2024906.011 <br />o° D.- sy <br />0 3. SEE UNIT EQUIPMENT SCHEDULE FOR ACTUAL OUTSIDE AIR SETPOINT FOR BALANCING; WHICH W ILL MEET OR EXCEED THE MINIMUM REQUIREMENT NOTED HEREIN. Unit Meets ASHRAE 62.1 Requirements Yes MSK <br />Q Issue D. <br />MARCH 07, 2024 <br />
The URL can be used to link to this page
Your browser does not support the video tag.