My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10521 19TH AVE SE EDWARD JONES 2025-10-27
>
Address Records
>
19TH AVE SE
>
10521
>
EDWARD JONES
>
10521 19TH AVE SE EDWARD JONES 2025-10-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/27/2025 9:17:17 AM
Creation date
12/12/2024 10:10:31 AM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
10521
Tenant Name
EDWARD JONES
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
254
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Scott Schreffler <br />From: Scott Schreffler <br />Sent: Tuesday, August 6, 2024 10:23 AM <br />To: seattlepermits@jhkelly.com <br />Subject: RE: M2406-088 - Edward Jones tenant Mechanical permit application - 1st Review <br />Good morning, <br />I've reviewed your resubmittal and have the following comments: <br />1. The suspended water heater appears to have been excluded from the structural analysis, and exceeds the 200 <br />pound limit per the structural suspension detail. Please provide an alternate detail or update this detail for the <br />water heater. <br />2. It appears that multiple references to the wrong codes still exist in the drawings. Please revise references and <br />any calculations or design elements that have changed as a result. For instance, the energy code has changed <br />significantly. <br />3. Alterations of existing buildings require the implementation of these comments. Please reference WSEC <br />C501.2.2, C503.4 <br />4. Commissioning is required for alterations to existing buildings. See WSEC C501.6 and C408. Please indicate <br />these requirements on the drawings. <br />5. The water heater scheduled on sheet M4 does not contain the information required per C404.2. Water heaters <br />shall be air -source heat pump type per C404.2.1, or note the exception used. Please revise. <br />6. Revise ventilation calculations per 2021 energy code and 2021 Washington Mechanical Code, or provide an <br />explanation in your response letter. <br />7. Please confirm that the ventilation system design is or is not providing heat per WSEC C403.7.3. <br />8. Energy code mechanical requirements, sheet M10 <br />a. page 1 of 25 — Please identify the location of the calculations per C403.1.2. <br />b. page 2 of 25 — Drawings do not clearly indicate required information per C403.3.1, C403.3.2 and or <br />C403.9.1. Pleaser clearly indicate where this information is located on the drawings. <br />c. page 3 of 25 — DOAS is required in the 2021 Energy Code. Please clarify your response to C403.3.5, <br />C403.5.4, C403.3.5.1, C403.3.5.1, and revise the design accordingly. <br />d. page 9 of 25 — Please provide dampers per WSEC C403.7.8, C403.7.8.3. and C403.7.8.4. <br />9. Energy code mechanical requirements sheet M11 <br />a. Page 11 of 25 — It is unclear how setback controls are being specified on sheet M2 as noted. Please <br />clarify. See C403.4.2. <br />b. Page 11 of 25 — Please provide automatic start and stop, or explain why automatic start and stop are <br />"NA." See C403.4.2.3. <br />c. Page 12 of 25 — It appears DDC is required per C403.4.11.1. Please revise or note the exception used. <br />d. Page 12 of 25 - Economizers are required per C403.5. Please revise or note exception(s) used. <br />e. Page 13 of 25 - It is unclear how plenums and shafts are sealed. Please clarify. See C403.10.1. <br />f. Page 13 of 25 — It is unclear how duct pressure are being specified on sheet M2 as noted. Please <br />clarify. See C403.10.2. It is unclear if high pressure duct testing is required. Please clarify, note <br />exceptions as applicable. See C403.10.2.3. <br />g. Page 13 and Duct insulation schedule on M4 — Please revise R-values. Duct insulation requirements <br />have increased in the 2021 code. Please reference table C403.10.1.1. <br />h. Page 14 of 25 — see 9d above. <br />10. Energy code mechanical requirements Sheet M12 <br />a. Pages 24 and 25 — Commissioning is required. Please revise these pages indicating where <br />Commissioning requirements are called out on plans. <br />1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.