Laserfiche WebLink
1/2 OF DUCT DIAMETER — <br />MINIMUM SO DAMPER DOES <br />NOT OBSTRUCT FLOW IN MAIN <br />�I,blc LAWRENCE <br />GROUP <br />SHEET METAL SCREW(TYP.) <br />RECTANGULAR GALVANIZED <br />STRUCTURE <br />SHEET METAL DUCT. <br />St. Louis <br />ROUND SHEET METAL DUCT <br />BEND TABS DOWN CLAMPING <br />FLEXIBLE DUCT. <br />MAX. LENGTH PER <br />CONNECT TO EXISTING VENT <br />PIPING OF EQUAL OR LARGER <br />319 North 4th Street <br />CONNECTORS SECURELY TO <br />SPECIFICATIONS <br />SHALL <br />Suite 1000 <br />DUCT AND LINER. <br />111'LN'7 FIELD VERIFYACTOR <br />EXACT POINT OF <br />SUSPEND ELBOW <br />'' CONNECITON. <br />St. Louis, Missouri 63102 <br />ATTACH FLEX DUCT <br />TO THE HARD DUCT. <br />WITH TIE <br />�y <br />F( �{. <br />SAFETY RELIEF VALVE <br />(314) 231-5700 <br />- <br />REFER TO NOTE 1. <br />i i 117 <br />(4) 1EXTENDED <br />1 1/2" 28 GAUGE GALVANIZEDDS <br />HARD DUCT <br />WITHOUT CRUSH NG <br />I i i I <br />TO (STEEL 2ODS HW� <br />a�T sore <br />26 GAUGE GALVANIZED <br />3" <br />EXTENSIONS WITH1 112" DEEP <br />NOTCHES. (LOOKS LIKE THIS <br />FLEXIBLE DUCT <br />I I I I <br />I I I I <br />3"X3'X3/8" L-IRONS W <br />ATTACHED TO <br />ce rvean�caOancTaa <br />SHEET METAL DUCT <br />WITH MANUAL <br />BEFORE BENDING TABS DOWN.) <br />PROVIDE DURABLE <br />II II ? <br />II II N <br />STRUCTURE ABOVE <br />EXPANSION TANK <br />To Be Determined <br />BALANCING DAMPER <br />ELBOW SUPPORT. 1X DUCT DIAMETER <br />I I I I <br />USE AMTROL ST-5C <br />REFER TO NOTE 2. <br />MINIMUM STRAIGHT <br />I I I I <br />SEISMICALLY BRACE <br />DUCT <br />i I I i <br />WATER HEATER AS <br />WRAP INSULATION (SEE <br />TRIM STRAPS AFTER <br />I I I I <br />REQUIRED. SEISMIC <br />SPECIFICATION SECTION7 <br />TIGHTENING <br />CEILING <br />I I I <br />BRACING SHALL BE A <br />233100-DUCTWORK) <br />NYLON TIE WRAP <br />I <br />li II <br />DEFERRED <br />SUBMITTAL. <br />ELECTRIC WATERHEATER.ATER. <br />PROVIDE TANK WITH <br />PROVIDE EXTENDED HANDLE FOR <br />SK-1 I I I I <br />INSULATION. <br />USE <br />USE WITH 1 1/2" INSULATION. FIT <br />DIFFUSER <br />I I I I <br />I <br />PIPE RELIEF LVE <br />INSULATION AROUND DAMPER <br />OPERATOR AND TAPE AS <br />I I i OB-2 <br />LINE TO DRAIN <br />PRO-SIONAL ENGINEER. <br />REQUIRED FOR NEAT INSTALLATION. <br />NOTES: <br />I j <br />22"X22"X2.5' HOLDRTE <br />LOCATE ABOVE NEW CEILING <br />1. TO ATTACH FLEX DUCT TO THE HARD DUCT, TAPE THE INNER <br />#40-PEND <br />SUSPENDED WATER <br />�' <br />IMEG <br />NOTES: <br />LINER TO THE HARD DUCT THEN ATTACH WITH TWO NYLON TIE <br />WRAPS; ONE FOR THE INNER LINER AND ONE FOR THE OUTER <br />15 <br />CONNECT TO EXISTING SANITARY <br />HEATER PLATFORM <br />1. THIS DETAIL APPLIES ONLY TO TAPS OFF LINED DUCTS. <br />SHELL. FOLD THE OUTER SHELL INSIDE ITSELF SO IT HAS NEAT <br />WASTE PIPING EQUAL OR <br />AND DRAIN PAN <br />2. TAP DOES NOT NEED TO BE CONICAL IF THE TAP IS NOT <br />EDGE$ PRIOR TO TIE WRAPPING. <br />2. DURABLE ELBOW SUPPORT ACCEPTABLE MANUFACTURER <br />LARGER SIZE. CONTRACTOR <br />O <br />�� <br />IMEG <br />E Orchartl Road, Suite 2505 <br />LOCATED BETWEEN FANS AND TERMINAL AIR BOXES, DUCT IS <br />AND MODEL: HART AND FLEX- <br />- SMARTFVED <br />SHALL FIELD VERIFY EXACT <br />PIPE 1-1/2" DRAIN TO <br />Gme 80111 <br />Greenwood Village, <br />NOT OVER 2" PRESSURE CLASS, AND ROUND DUCT IS NOT <br />FLEXFLOW, TITUS- FLEXRIGHT, OR APPROVED EQUAL. <br />RIGHT, EQUAL. <br />POINT OF CONNECITON. <br />OUTLET BOX INDIRECT <br />Phone: 303.79 0 <br />ER 1 . <br />DRAIN, PROVIDE WITH <br />AIR GAP <br />,:24 <br />IMEG Project No: 24000280.07 <br />ROUND DUCT TAP CONNECTION <br />(CONICAL/LINED) <br />� No SALE <br />SUPPLY AIR <br />OUTLET DUCT <br />(MINIMUM 5' LONG). <br />DUCTWORK $HALL BE <br />FIBERGLASS LINED WITH <br />MINIMUM 1-1/2" INSULATION <br />FLEXIBLE <br />CONNECTOR, <br />CONDENSATE DRAIN PIPING TYPICAL. <br />SHALL BE ROUTED TO OUTLET <br />BOX AND SHALL TERMINATE <br />WITH MINIMUM 1" AIR GAP <br />FITTING. <br />DRAIN FROM <br />AIR HANDLER <br />4' MINIMUM DISTANCE <br />FROM OUTLET OF UNIT <br />TO <br />FIRST DUCT TAKEOFF <br />REFRIGERANT PIPING <br />(R$/RL) <br />COIL UNIT <br />2" DEEP UNI-STRUT <br />SUPPORTS <br />(4 PER UNIT) <br />FLEXIBLE <br />CONNECTOR, <br />TYPICAL. <br />5 NO SALE <br />FAN COIL UNIT DETAIL <br />A <br />DIFFUSER CONNECTION DETAIL <br />(W/ RADIUS FORMING ELBOW) <br />2 NO SCALE <br />ISOLATOR, <br />TYPICAL. <br />1/2" ALL -THREAD ROD <br />RETURN AIR DUCTWORK. DUCTWORK <br />SHALL <br />BE FIBERGLASS LINED WITH MINIMUM 1" <br />INSULATION. <br />MANUAL BALANCING DAMPER <br />BALANCING <br />DAMPER OUTSIDE AIR DUCTWORK. <br />PROVIDE ROUND INSULATED <br />DUCT. <br />HW PIPING IN WALL TO SERVE <br />DISHWASHER. PROVIDE WITH <br />BACKFLOW PREVENTER <br />LOOP PER MANUFACTURER'S <br />INSTRUCTIONS AND SECTION <br />409 & 802.1.6 OF IPC 2018 <br />CONNECT TO UNDERSIDE <br />OF COUNTER. <br />PLUMBING ISOMETRIC <br />3 NO SCAI F <br />MAINTAIN ADA CLEARANCES <br />AS REQUIRED. <br />0o DISHWASHING <br />/MACHINE <br />$INK WITH GARABAGE <br />DISPOSAL <br />CONNECTION OF <br />TO <br />GARAGABE DISPOSAL INLET <br />OR SINK TAILPIECE. <br />SAN <br />NOTE: <br />SINK VENT PIPING NOT COVERED IN <br />THIS DETAIL. SEE ISOMETRIC. <br />DISHWASHER/GARBAGE <br />DISPOSAL CONNECTION DETAIL <br />NO SCALE <br />6 <br />WATER HEATER MOUNTING <br />(SUSPENDED) <br />4 No SCALE <br />45DEGREE <br />ENTRY G 45° <br />(L=4" OR W/4; WHICHEVER IS LARGER) <br />45DEGREE <br />ENTRY G 45° <br />NOTES <br />ANCING DAMPER <br />F <br />ERE SHOWN <br />ER <br />LINED DUCT CONNECTION <br />(NO EXPOSED LINER EDGES) <br />D1>D2 <br />45 DEGREE LEAD IN <br />FLANGED <br />CONICAL <br />DOVETAIL JOINT <br />1. DO NOT USE CONNECTIONS WITH SCOOPS. <br />2. FIT ALL CONNECTIONS TO AVOID VISIBLE OPENINGS AND <br />SECURE THEM SUITABLY FOR THE PRESSURE CLASS. <br />3. ADDITIONAL MECHANICAL FASTENERS ARE REQUIRED FOR <br />4"W.G. AND OVER. <br />4. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION. <br />BRANCH CONNECTIONS <br />NO SCALE <br />EXISTING ENERGY RECOVERY VENTILATOR <br />PERFORMANCE <br />TEMP RECOVERY EFFICIENCY % <br />ENTHALPY RECOVERY EFFICIENCY % <br />DESIGN TEMPERATURES <br />ELECTRICAL <br />OF <br />TAG <br />DESIGN <br />AIRFLOW <br />CFM <br />E.S.P <br />IN. <br />W.C. <br />DUCT <br />CONNECTION <br />IN. <br />SOUND <br />PRESSURE <br />DBA <br />COOLING@ <br />75%/ 100%AIRFLOW <br />HEATING@ <br />75%/ 100%AIRFLOW <br />COOLING@ <br />75%/ 100%AIRFLOW <br />HEATING@ <br />75%/ 100%AIRFLOW <br />SUMMER <br />WINTER <br />POWER <br />V-PH-HZ <br />MCA/MOCP <br />(AMPS) <br />WT <br />LBS <br />MANUFACTURER& MODEL# <br />NOTES <br />OSA EAT (DEG. F) <br />DBNJB <br />RA EAT (DEG. F) <br />DB/%RH <br />SA LAT (DEG. F) <br />DBNJB <br />EA LAT (DEG. F) <br />DEANS <br />OSA EAT (DEG. F) <br />IDS <br />RA EAT (DEG. F) <br />DB/%RH <br />SA LAT (DEG. F) <br />DEANS <br />EA LAT (DEG. F) <br />DB/WB <br />(E)ERV-2 <br />1200 <br />0.56 <br />14"0 <br />38.0 <br />749/6/729/. <br />739/6/709/6 <br />52%/49% <br />639/6/609/6 <br />80.9/63.8 <br />75/30 <br />74.4/60.6 <br />80.9/60.4 <br />21.0 <br />70/30 <br />57.6/46.3 <br />39.7/37.1 <br />2081230-1-60 <br />8.1/15 <br />350 <br />DAIKIN VAM1200GVJU <br />1 <br />NOTES: <br />1. ENERGY RECOVERY VENTILATOR IS PROVIDED WITH FILTRATION UPSTREAM OF THE OUTSIDE AIR AND EXHAUST AIR OPENINGS. <br />W <br />o <br />:apS GI}T FE�V?� <br />oNAL'EN <br />oe.al.a�ay <br />E.poo�• ro•�715 <br />LU <br />W <br />00 <br />T <br />V I <br />O <br />70 <br />LL <br />U N <br />O <br />ad <br />I I0 <br />m W <br />co N VJ <br />�ealm� <br />mnvli,-pare aawitlg orrea y <br />aMng aM Mtaib on it are iM1e sde DroDery W NIt ­11 It e <br />may Ee=d-L Ixb apecifc Droled only. <br />iereproducetl,In wMb or <br />rent' oNermpd a puryaae or Poled d,h Me <br />No. Daacriptbn Data <br />1 Revision 1 Date 1 <br />2 FOR CONSTRUCTION 07/11/2024 <br />3 MECH PERMIT 07/24/2024 <br />5 MECH REVIEW OS/21/2024 <br />laa ma. <br />MECHANICAL AND <br />PLUMBING DETAILS <br />AND SCHEDULES <br />p� dx a ­1 <br />2024906.011 <br />0rewn er <br />MSK M3Iwie one: <br />MARCH 27. 2024 <br />