10521 19TH AVE SE EDWARD JONES 2025-10-27
>
Address Records
>
19TH AVE SE
>
10521
>
EDWARD JONES
>
10521 19TH AVE SE EDWARD JONES 2025-10-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/27/2025 9:17:17 AM
Creation date
12/12/2024 10:10:31 AM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
10521
Tenant Name
EDWARD JONES
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
254
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IMC 2021 VENTILATION RATE PROCEDURE CALCULATIONS <br />OCCUPANT <br />OCCUPANT <br />BREATHING <br />TABLE6-2ZONE <br />TOTALSUPPLY <br />SYSTEM <br />OUTDOOR <br />AREA <br />DENSITY <br />OVER -VENTILATION <br />ZONE <br />AIR <br />AIRTOZONEAT <br />ZONE <br />VENTILATION <br />MINIMUM <br />MINIMUM <br />UNIT <br />FLOOR <br />ROOM <br />ROOM NAME <br />ZONE TYPE <br />AREA <br />AIRFLOW <br />OUTDOOR <br />PEOPLE <br />OCCUPANT <br />PERCENTAGE <br />OUTDOOR <br />DISTRIBUTION <br />CONDITION <br />VENTILATION <br />EFFICIENCY <br />PERCENTAGE <br />OUTSIDEAIRFLOW <br />NUMBER <br />SO FT <br />RATE <br />AIRFLOW RATE <br />PER 1000 <br />QUANTITY <br />AIRFLOW RATE <br />EFFECTIVENESS <br />ANALYZED <br />EFFICIENCY <br />NOTE 2 <br />AIRFLOW AT <br />AT UNIT <br />CFM/PER <br />CFM/SQ FT <br />SO FT <br />CFM <br />(Ez) <br />CFM - NOTE 1 <br />(Evz) <br />(Ev) <br />UNIT <br />NOTE 3 <br />FCU - 1 <br />1st <br />107 <br />BREAK <br />Break rooms <br />155 <br />5.0 <br />0.06 <br />25 <br />4 <br />0% <br />29 <br />0.8 <br />640 <br />0.99 <br />0.83 <br />- <br />- <br />let <br />106C <br />SMALL CONFERENCE <br />Conference/meeting <br />84 <br />5.0 <br />0.06 <br />50 <br />4 <br />0% <br />26 <br />0.8 <br />180 <br />0.87 <br />0.83 <br />- <br />- <br />tat <br />106D <br />SMALL CONFERENCE <br />Conference/meeting <br />81 <br />5.0 <br />0.06 <br />50 <br />4 <br />0% <br />25 <br />0.8 <br />140 <br />0.83 <br />0.83 <br />- <br />- <br />tat <br />103 <br />PASSAGE <br />Condors <br />166 <br />0.0 <br />0.06 <br />0 <br />0 <br />0% <br />10 <br />0.8 <br />840 <br />1.04 <br />0.83 <br />- <br />- <br />FCU - 1 TOTALS <br />1800 <br />0.83 1 6 % <br />1- <br />SPECIFIC NOTES: <br />1. TOTAL SUPPLY AIR AT CONDITION ANALYZED USES THE MAXIMUM AIRFLOW PROVIDED TO THE ZONE DURING THE HEATING OR COOLING MODE, WHICHEVER IS BEING ANALYZED. <br />2. SYSTEM VENTILATION EFFICIENCY IS EQUAL TO THE LOWEST ZONE VENTILATION EFFICIENCY OF ALL ROOMS SERVED BY THE UNIT. <br />Unit Outside Airflow Balance Setpoint [cfm] <br />110 <br />3. SEE UNIT EQUIPMENT SCHEDULE FOR ACTUAL OUTSIDE AIR SETPOINT FOR BALANCING; WHICH WILL MEET OR EXCEED THE MINIMUM REQUIREMENT NOTED HEREIN. <br />Unit Meets IMC Requirements <br />Yes <br />IMC 2021 VENTILATION RATE PROCEDURE CALCULATIONS <br />UNIT <br />FLOOR <br />ROOM <br />NUMBER <br />ROOM NAME <br />ZONE TYPE <br />AREA <br />SO FT <br />OCCUPANT <br />OUTDOOR <br />AIRFLOW <br />RATE <br />CFM/PER <br />AREA <br />OUTDOOR <br />AIRFLOW RATE <br />CFM/SQ FT <br />OCCUPANT <br />DENSITY <br />PEOPLE <br />PER 1000 <br />SO FT <br />OCCUPANT <br />QUANTITY <br />OVER -VENTILATION <br />PERCENTAGE <br />BREATHING <br />ZONE <br />OUTDOOR <br />AIRFLOW RATE <br />CFM <br />TABLE6-2ZONE <br />AIR <br />DISTRIBUTION <br />EFFECTIVENESS <br />(Ez) <br />TOTALSUPPLY <br />AIRTOZONEAT <br />CONDITION <br />ANALYZED <br />CFM - NOTE 1 <br />ZONE <br />VENTILATION <br />EFFICIENCY <br />(Evz) <br />SYSTEM <br />VENTILATION <br />EFFICIENCY <br />NOTE 2 <br />(Ev) <br />MINIMUM <br />PERCENTAGE <br />AIRFLOW AT <br />UNIT <br />MINIMUM <br />OUTSIDEAIRFLOW <br />AT UNIT <br />NOTE 3 <br />FCU-2 <br />106A <br />BRANCH SUPPORT <br />Office space <br />224 <br />5.0 <br />0.06 <br />5 <br />1 <br />0% <br />19 <br />0.8 <br />175 <br />0.99 <br />0.89 <br />- <br />- <br />102A <br />OFFICE <br />Office space <br />64 <br />5.0 <br />0.06 <br />5 <br />1 <br />0% <br />9 <br />0.8 <br />55 <br />0.93 <br />0.89 <br />- <br />- <br />102B <br />OFFICE <br />Office space <br />64 <br />5.0 <br />0.06 <br />5 <br />1 <br />0% <br />9 <br />0.8 <br />55 <br />0.93 <br />0.89 <br />- <br />- <br />102C <br />OFFICE <br />Office space <br />64 <br />5.0 <br />0.06 <br />5 <br />1 <br />0% <br />9 <br />0.8 <br />55 <br />0.93 <br />0.89 <br />- <br />- <br />102D <br />OFFICE <br />Office space <br />64 <br />5.0 <br />0.06 <br />5 <br />1 <br />0% <br />9 <br />0.8 <br />55 <br />0.93 <br />0.89 <br />- <br />- <br />102E <br />OFFICE <br />Office space <br />64 <br />5.0 <br />0.06 <br />5 <br />1 <br />0% <br />9 <br />0.8 <br />55 <br />0.93 <br />0.89 <br />- <br />- <br />102F <br />OFFICE <br />Office space <br />64 <br />5.0 <br />0.06 <br />5 <br />1 <br />0% <br />9 <br />0.8 <br />55 <br />0.93 <br />0.89 <br />- <br />- <br />101E <br />BRANCH SUPPORT <br />Office space <br />190 <br />5.0 <br />0.06 <br />5 <br />1 <br />0% <br />16 <br />0.8 <br />155 <br />1.00 <br />0.89 <br />- <br />- <br />103 <br />PASSAGE <br />Corridors <br />434 <br />0.0 <br />0.06 <br />0 <br />0 <br />0% <br />26 <br />0.8 <br />235 <br />0.99 <br />0.89 <br />- <br />- <br />104 <br />EQUIP/SUPPLY <br />Occupiable storage rooms for dry materials <br />85 <br />5.0 <br />0.06 <br />2 <br />0 <br />0% <br />6 <br />0.8 <br />70 <br />1.02 <br />0.89 <br />- <br />- <br />108 <br />STORAGE <br />Storage rooms <br />78 <br />0.0 <br />0.12 <br />0 <br />0 <br />0% <br />9 <br />0.8 <br />50 <br />0.89 <br />0.89 <br />- <br />- <br />109 <br />LOUNGE <br />Office space <br />68 <br />5.0 <br />0.06 <br />5 <br />0 <br />0% <br />6 <br />0.8 <br />55 <br />1.00 <br />0.89 <br />- <br />- <br />FCU-2 TOTALS 1 1070 1 0.89 1 14% 152 <br />1. TOTAL SUPPLYAIR AT CONDITION ANALYZED USES THE MAXIMUM AIRFLOW PROVIDED TO THE ZONE DURING THE HEATING OR COOLING MODE, WHICHEVER IS BEING ANALYZED. <br />2. SYSTEM VENTILATION EFFICIENCY IS EQUAL TO THE LOWEST ZONE VENTILATION EFFICIENCY OF ALL ROOMS SERVED BY THE UNIT. <br />3. SEE UNIT EQUIPMENT SCHEDULE FOR ACTUAL OUTSIDE AIR SETPOINT FOR BALANCING; WHICH WILL MEET OR EXCEED THE MINIMUM REQUIREMENT NOTED HEREIN. <br />Unit Outside Airflow Balance Setpoint[cfm] 155 <br />Unit Meets IMC Requirements Yes <br />IMC 2021 VENTILATION RATE PROCEDURE CALCULATIONS <br />OCCUPANT <br />OCCUPANT <br />BREATHING <br />TABLE6-2ZONE <br />TOTAL SUPPLY <br />SYSTEM <br />OUTDOOR <br />AREA <br />DENSITY <br />OVER -VENTILATION <br />ZONE <br />AIR <br />AIRTOZONEAT <br />ZONE <br />VENTILATION <br />MINIMUM <br />MINIMUM <br />UNIT FLOOR <br />ROOM <br />ROOM NAME <br />ZONE TYPE <br />AREA <br />AIRFLOW <br />OUTDOOR <br />PEOPLE <br />OCCUPANT <br />PERCENTAGE <br />OUTDOOR <br />DISTRIBUTION <br />CONDITION <br />VENTILATION <br />EFFICIENCY <br />PERCENTAGE <br />OUTSIDEAIRFLOW <br />NUMBER <br />SO FT <br />RATE <br />AIRFLOW RATE <br />PER 1000 <br />QUANTITY <br />AIRFLOW RATE <br />EFFECTIVENESS <br />ANALYZED <br />EFFICIENCY <br />NOTE 2 <br />AIRFLOW AT <br />AT UNIT <br />CFM/PER <br />CFM/SQ FT <br />SO FT <br />CFM <br />(Ez) <br />CFM - NOTE 1 <br />(Evz) <br />(Ev) <br />UNIT <br />NOTE 3 <br />FCU-3 <br />106A <br />MEDIUM CONFERENCE <br />Conference/meeting <br />151 <br />5.0 <br />0.06 <br />50 <br />8 <br />0% <br />47 <br />0.8 <br />350 <br />0.91 <br />0.91 <br />- <br />- <br />100 <br />WELCOME <br />Main entry lobbies <br />1 344 <br />1 5.0 <br />0.06 <br />1 10 <br />1 3 <br />0% <br />1 38 <br />0.8 <br />720 <br />1.01 <br />1 0.91 <br />- <br />- <br />'CU-3 TOTALS 1 1070 1 0.91 1 9% 1 93 <br />1. TOTAL SUPPLYAIR AT CONDITION ANALYZED USES THE MAXIMUM AIRFLOW PROVIDED TO THE ZONE DURING THE HEATING OR COOLING MODE, WHICHEVER IS BEING ANALYZED. <br />2. SYSTEM VENTILATION EFFICIENCY IS EQUAL TO THE LOWEST ZONE VENTILATION EFFICIENCY OF ALL ROOMS SERVED BY THE UNIT. <br />3. SEE UNIT EQUIPMENT SCHEDULE FOR ACTUAL OUTSIDE AIR SETPOINT FOR BALANCING; WHICH WILL MEET OR EXCEED THE MINIMUM REQUIREMENT NOTED HEREIN. <br />Unit Outside Airflow Balance Setpoint[cfm] 95 <br />Unit Meets IMC Requirements Yes <br />IMC 2021 VENTILATION RATE PROCEDURE CALCULATIONS <br />OCCUPANT <br />OCCUPANT <br />BREATHING <br />TABLE6-2ZONE <br />TOTAL SUPPLY <br />SYSTEM <br />OUTDOOR <br />AREA <br />DENSITY <br />OVER -VENTILATION <br />ZONE <br />AIR <br />AIRTOZONEAT <br />ZONE <br />VENTILATION <br />MINIMUM <br />MINIMUM <br />UNIT <br />FLOOR <br />ROOM <br />ROOM NAME <br />ZONE TYPE <br />AREA <br />AIRFLOW <br />OUTDOOR <br />PEOPLE <br />OCCUPANT <br />PERCENTAGE <br />OUTDOOR <br />DISTRIBUTION <br />CONDITION <br />VENTILATION <br />EFFICIENCY <br />PERCENTAGE <br />OUTSIDE AIRFLOW <br />NUMBER <br />SO FT <br />RATE <br />AIRFLOW RATE <br />PER 1000 <br />QUANTITY <br />AIRFLOW RATE <br />EFFECTIVENESS <br />ANALYZED <br />EFFICIENCY <br />NOTE 2 <br />AIRFLOW AT <br />AT UNIT <br />CFM/PER <br />CFM/SQ FT <br />SO FT <br />CFM <br />(Ez) <br />CFM - NOTE 1 <br />(Evz) <br />(Ev) <br />UNIT <br />NOTE 3 <br />FCU-4 <br />106B <br />LARGE CONFERENCE <br />Conference/meeting <br />241 <br />5.0 <br />0.06 <br />50 <br />12 <br />0% <br />75 <br />0.8 <br />430 <br />0.96 <br />0.96 <br />- <br />- <br />FCU -,t IT.LS 430 1 0.96 1 18% 1 78 <br />LAWRENCE <br />GROUP <br />St. Louis <br />319 North 4th Street <br />Suite 1000 <br />St. Louis, Missouri 63102 <br />(314)231-5700 <br />To Be Determined <br />IROIESSDNAL 4`cwe <br />.IMEG <br />MEG <br />7600 E Orchard Road, Suite 250S <br />Greenwood Village, CO 80111 <br />Phone: 303.796.6000 <br />IMEG Project No: 24000280.07 <br />W <br />C <br />e <br />:apS GI}T FE�V?� <br />ONAL' N <br />oe.al.a�ay <br />E.poo�• ro•�7e <br />LU <br />rn <br />0 <br />) <br />_ I <br />O <br />� <br />U N <br />O ( <br />I) <br />pD LU <br />co N fn <br />orym <br />-bliw-pare aawi <br />-Ere aM-on N are mesde P.P.1 W Ne <br />No. Description Date <br />1 Revision 1 Date 1 <br />2 FOR CONSTRUCTION 10711112024 <br />3 1 MECH PERMIT 07/24/2024 <br />5 1 MECH REVIEW 101512112074 <br />MECHANICAL <br />SCHEDULES <br />1. TOTAL SUPPLYAIR AT CONDITION ANALYZED USES THE MAXIMUM AIRFLOW PROVIDED TO THE ZONE DURING THE HEATING OR COOLING MODE, WHICHEVER IS BEING ANALYZED. <br />2. SYSTEM VENTILATION EFFICIENCY IS EQUAL TO THE LOWEST ZONE VENTILATION EFFICIENCY OF ALL ROOMS SERVED BY THE UNIT. <br />3. SEE UNIT EQUIPMENT SCHEDULE FOR ACTUAL OUTSIDE AIR SETPOINT FOR BALANCING; WHICH WILL MEET OR EXCEED THE MINIMUM REQUIREMENT NOTED HEREIN. <br />Unit Outside Airflow Balance Setpoint [cfm] 80 <br />Unit Meets IMC Requirements Yes <br />PgeGNunEx'.-NanEx. <br />2024906.011 <br />0rewn ar <br />MSK <br />Iwi. on.: <br />MARCH 27. 2024 <br />