IMC 2021 VENTILATION RATE PROCEDURE CALCULATIONS <br />OCCUPANT <br />OCCUPANT <br />BREATHING <br />TABLE6-2ZONE <br />TOTALSUPPLY <br />SYSTEM <br />OUTDOOR <br />AREA <br />DENSITY <br />OVER -VENTILATION <br />ZONE <br />AIR <br />AIRTOZONEAT <br />ZONE <br />VENTILATION <br />MINIMUM <br />MINIMUM <br />UNIT <br />FLOOR <br />ROOM <br />ROOM NAME <br />ZONE TYPE <br />AREA <br />AIRFLOW <br />OUTDOOR <br />PEOPLE <br />OCCUPANT <br />PERCENTAGE <br />OUTDOOR <br />DISTRIBUTION <br />CONDITION <br />VENTILATION <br />EFFICIENCY <br />PERCENTAGE <br />OUTSIDEAIRFLOW <br />NUMBER <br />SO FT <br />RATE <br />AIRFLOW RATE <br />PER 1000 <br />QUANTITY <br />AIRFLOW RATE <br />EFFECTIVENESS <br />ANALYZED <br />EFFICIENCY <br />NOTE 2 <br />AIRFLOW AT <br />AT UNIT <br />CFM/PER <br />CFM/SQ FT <br />SO FT <br />CFM <br />(Ez) <br />CFM - NOTE 1 <br />(Evz) <br />(Ev) <br />UNIT <br />NOTE 3 <br />FCU - 1 <br />1st <br />107 <br />BREAK <br />Break rooms <br />155 <br />5.0 <br />0.06 <br />25 <br />4 <br />0% <br />29 <br />0.8 <br />640 <br />0.99 <br />0.83 <br />- <br />- <br />let <br />106C <br />SMALL CONFERENCE <br />Conference/meeting <br />84 <br />5.0 <br />0.06 <br />50 <br />4 <br />0% <br />26 <br />0.8 <br />180 <br />0.87 <br />0.83 <br />- <br />- <br />tat <br />106D <br />SMALL CONFERENCE <br />Conference/meeting <br />81 <br />5.0 <br />0.06 <br />50 <br />4 <br />0% <br />25 <br />0.8 <br />140 <br />0.83 <br />0.83 <br />- <br />- <br />tat <br />103 <br />PASSAGE <br />Condors <br />166 <br />0.0 <br />0.06 <br />0 <br />0 <br />0% <br />10 <br />0.8 <br />840 <br />1.04 <br />0.83 <br />- <br />- <br />FCU - 1 TOTALS <br />1800 <br />0.83 1 6 % <br />1- <br />SPECIFIC NOTES: <br />1. TOTAL SUPPLY AIR AT CONDITION ANALYZED USES THE MAXIMUM AIRFLOW PROVIDED TO THE ZONE DURING THE HEATING OR COOLING MODE, WHICHEVER IS BEING ANALYZED. <br />2. SYSTEM VENTILATION EFFICIENCY IS EQUAL TO THE LOWEST ZONE VENTILATION EFFICIENCY OF ALL ROOMS SERVED BY THE UNIT. <br />Unit Outside Airflow Balance Setpoint [cfm] <br />110 <br />3. SEE UNIT EQUIPMENT SCHEDULE FOR ACTUAL OUTSIDE AIR SETPOINT FOR BALANCING; WHICH WILL MEET OR EXCEED THE MINIMUM REQUIREMENT NOTED HEREIN. <br />Unit Meets IMC Requirements <br />Yes <br />IMC 2021 VENTILATION RATE PROCEDURE CALCULATIONS <br />UNIT <br />FLOOR <br />ROOM <br />NUMBER <br />ROOM NAME <br />ZONE TYPE <br />AREA <br />SO FT <br />OCCUPANT <br />OUTDOOR <br />AIRFLOW <br />RATE <br />CFM/PER <br />AREA <br />OUTDOOR <br />AIRFLOW RATE <br />CFM/SQ FT <br />OCCUPANT <br />DENSITY <br />PEOPLE <br />PER 1000 <br />SO FT <br />OCCUPANT <br />QUANTITY <br />OVER -VENTILATION <br />PERCENTAGE <br />BREATHING <br />ZONE <br />OUTDOOR <br />AIRFLOW RATE <br />CFM <br />TABLE6-2ZONE <br />AIR <br />DISTRIBUTION <br />EFFECTIVENESS <br />(Ez) <br />TOTALSUPPLY <br />AIRTOZONEAT <br />CONDITION <br />ANALYZED <br />CFM - NOTE 1 <br />ZONE <br />VENTILATION <br />EFFICIENCY <br />(Evz) <br />SYSTEM <br />VENTILATION <br />EFFICIENCY <br />NOTE 2 <br />(Ev) <br />MINIMUM <br />PERCENTAGE <br />AIRFLOW AT <br />UNIT <br />MINIMUM <br />OUTSIDEAIRFLOW <br />AT UNIT <br />NOTE 3 <br />FCU-2 <br />106A <br />BRANCH SUPPORT <br />Office space <br />224 <br />5.0 <br />0.06 <br />5 <br />1 <br />0% <br />19 <br />0.8 <br />175 <br />0.99 <br />0.89 <br />- <br />- <br />102A <br />OFFICE <br />Office space <br />64 <br />5.0 <br />0.06 <br />5 <br />1 <br />0% <br />9 <br />0.8 <br />55 <br />0.93 <br />0.89 <br />- <br />- <br />102B <br />OFFICE <br />Office space <br />64 <br />5.0 <br />0.06 <br />5 <br />1 <br />0% <br />9 <br />0.8 <br />55 <br />0.93 <br />0.89 <br />- <br />- <br />102C <br />OFFICE <br />Office space <br />64 <br />5.0 <br />0.06 <br />5 <br />1 <br />0% <br />9 <br />0.8 <br />55 <br />0.93 <br />0.89 <br />- <br />- <br />102D <br />OFFICE <br />Office space <br />64 <br />5.0 <br />0.06 <br />5 <br />1 <br />0% <br />9 <br />0.8 <br />55 <br />0.93 <br />0.89 <br />- <br />- <br />102E <br />OFFICE <br />Office space <br />64 <br />5.0 <br />0.06 <br />5 <br />1 <br />0% <br />9 <br />0.8 <br />55 <br />0.93 <br />0.89 <br />- <br />- <br />102F <br />OFFICE <br />Office space <br />64 <br />5.0 <br />0.06 <br />5 <br />1 <br />0% <br />9 <br />0.8 <br />55 <br />0.93 <br />0.89 <br />- <br />- <br />101E <br />BRANCH SUPPORT <br />Office space <br />190 <br />5.0 <br />0.06 <br />5 <br />1 <br />0% <br />16 <br />0.8 <br />155 <br />1.00 <br />0.89 <br />- <br />- <br />103 <br />PASSAGE <br />Corridors <br />434 <br />0.0 <br />0.06 <br />0 <br />0 <br />0% <br />26 <br />0.8 <br />235 <br />0.99 <br />0.89 <br />- <br />- <br />104 <br />EQUIP/SUPPLY <br />Occupiable storage rooms for dry materials <br />85 <br />5.0 <br />0.06 <br />2 <br />0 <br />0% <br />6 <br />0.8 <br />70 <br />1.02 <br />0.89 <br />- <br />- <br />108 <br />STORAGE <br />Storage rooms <br />78 <br />0.0 <br />0.12 <br />0 <br />0 <br />0% <br />9 <br />0.8 <br />50 <br />0.89 <br />0.89 <br />- <br />- <br />109 <br />LOUNGE <br />Office space <br />68 <br />5.0 <br />0.06 <br />5 <br />0 <br />0% <br />6 <br />0.8 <br />55 <br />1.00 <br />0.89 <br />- <br />- <br />FCU-2 TOTALS 1 1070 1 0.89 1 14% 152 <br />1. TOTAL SUPPLYAIR AT CONDITION ANALYZED USES THE MAXIMUM AIRFLOW PROVIDED TO THE ZONE DURING THE HEATING OR COOLING MODE, WHICHEVER IS BEING ANALYZED. <br />2. SYSTEM VENTILATION EFFICIENCY IS EQUAL TO THE LOWEST ZONE VENTILATION EFFICIENCY OF ALL ROOMS SERVED BY THE UNIT. <br />3. SEE UNIT EQUIPMENT SCHEDULE FOR ACTUAL OUTSIDE AIR SETPOINT FOR BALANCING; WHICH WILL MEET OR EXCEED THE MINIMUM REQUIREMENT NOTED HEREIN. <br />Unit Outside Airflow Balance Setpoint[cfm] 155 <br />Unit Meets IMC Requirements Yes <br />IMC 2021 VENTILATION RATE PROCEDURE CALCULATIONS <br />OCCUPANT <br />OCCUPANT <br />BREATHING <br />TABLE6-2ZONE <br />TOTAL SUPPLY <br />SYSTEM <br />OUTDOOR <br />AREA <br />DENSITY <br />OVER -VENTILATION <br />ZONE <br />AIR <br />AIRTOZONEAT <br />ZONE <br />VENTILATION <br />MINIMUM <br />MINIMUM <br />UNIT FLOOR <br />ROOM <br />ROOM NAME <br />ZONE TYPE <br />AREA <br />AIRFLOW <br />OUTDOOR <br />PEOPLE <br />OCCUPANT <br />PERCENTAGE <br />OUTDOOR <br />DISTRIBUTION <br />CONDITION <br />VENTILATION <br />EFFICIENCY <br />PERCENTAGE <br />OUTSIDEAIRFLOW <br />NUMBER <br />SO FT <br />RATE <br />AIRFLOW RATE <br />PER 1000 <br />QUANTITY <br />AIRFLOW RATE <br />EFFECTIVENESS <br />ANALYZED <br />EFFICIENCY <br />NOTE 2 <br />AIRFLOW AT <br />AT UNIT <br />CFM/PER <br />CFM/SQ FT <br />SO FT <br />CFM <br />(Ez) <br />CFM - NOTE 1 <br />(Evz) <br />(Ev) <br />UNIT <br />NOTE 3 <br />FCU-3 <br />106A <br />MEDIUM CONFERENCE <br />Conference/meeting <br />151 <br />5.0 <br />0.06 <br />50 <br />8 <br />0% <br />47 <br />0.8 <br />350 <br />0.91 <br />0.91 <br />- <br />- <br />100 <br />WELCOME <br />Main entry lobbies <br />1 344 <br />1 5.0 <br />0.06 <br />1 10 <br />1 3 <br />0% <br />1 38 <br />0.8 <br />720 <br />1.01 <br />1 0.91 <br />- <br />- <br />'CU-3 TOTALS 1 1070 1 0.91 1 9% 1 93 <br />1. TOTAL SUPPLYAIR AT CONDITION ANALYZED USES THE MAXIMUM AIRFLOW PROVIDED TO THE ZONE DURING THE HEATING OR COOLING MODE, WHICHEVER IS BEING ANALYZED. <br />2. SYSTEM VENTILATION EFFICIENCY IS EQUAL TO THE LOWEST ZONE VENTILATION EFFICIENCY OF ALL ROOMS SERVED BY THE UNIT. <br />3. SEE UNIT EQUIPMENT SCHEDULE FOR ACTUAL OUTSIDE AIR SETPOINT FOR BALANCING; WHICH WILL MEET OR EXCEED THE MINIMUM REQUIREMENT NOTED HEREIN. <br />Unit Outside Airflow Balance Setpoint[cfm] 95 <br />Unit Meets IMC Requirements Yes <br />IMC 2021 VENTILATION RATE PROCEDURE CALCULATIONS <br />OCCUPANT <br />OCCUPANT <br />BREATHING <br />TABLE6-2ZONE <br />TOTAL SUPPLY <br />SYSTEM <br />OUTDOOR <br />AREA <br />DENSITY <br />OVER -VENTILATION <br />ZONE <br />AIR <br />AIRTOZONEAT <br />ZONE <br />VENTILATION <br />MINIMUM <br />MINIMUM <br />UNIT <br />FLOOR <br />ROOM <br />ROOM NAME <br />ZONE TYPE <br />AREA <br />AIRFLOW <br />OUTDOOR <br />PEOPLE <br />OCCUPANT <br />PERCENTAGE <br />OUTDOOR <br />DISTRIBUTION <br />CONDITION <br />VENTILATION <br />EFFICIENCY <br />PERCENTAGE <br />OUTSIDE AIRFLOW <br />NUMBER <br />SO FT <br />RATE <br />AIRFLOW RATE <br />PER 1000 <br />QUANTITY <br />AIRFLOW RATE <br />EFFECTIVENESS <br />ANALYZED <br />EFFICIENCY <br />NOTE 2 <br />AIRFLOW AT <br />AT UNIT <br />CFM/PER <br />CFM/SQ FT <br />SO FT <br />CFM <br />(Ez) <br />CFM - NOTE 1 <br />(Evz) <br />(Ev) <br />UNIT <br />NOTE 3 <br />FCU-4 <br />106B <br />LARGE CONFERENCE <br />Conference/meeting <br />241 <br />5.0 <br />0.06 <br />50 <br />12 <br />0% <br />75 <br />0.8 <br />430 <br />0.96 <br />0.96 <br />- <br />- <br />FCU -,t IT.LS 430 1 0.96 1 18% 1 78 <br />LAWRENCE <br />GROUP <br />St. Louis <br />319 North 4th Street <br />Suite 1000 <br />St. Louis, Missouri 63102 <br />(314)231-5700 <br />To Be Determined <br />IROIESSDNAL 4`cwe <br />.IMEG <br />MEG <br />7600 E Orchard Road, Suite 250S <br />Greenwood Village, CO 80111 <br />Phone: 303.796.6000 <br />IMEG Project No: 24000280.07 <br />W <br />C <br />e <br />:apS GI}T FE�V?� <br />ONAL' N <br />oe.al.a�ay <br />E.poo�• ro•�7e <br />LU <br />rn <br />0 <br />) <br />_ I <br />O <br />� <br />U N <br />O ( <br />I) <br />pD LU <br />co N fn <br />orym <br />-bliw-pare aawi <br />-Ere aM-on N are mesde P.P.1 W Ne <br />No. Description Date <br />1 Revision 1 Date 1 <br />2 FOR CONSTRUCTION 10711112024 <br />3 1 MECH PERMIT 07/24/2024 <br />5 1 MECH REVIEW 101512112074 <br />MECHANICAL <br />SCHEDULES <br />1. TOTAL SUPPLYAIR AT CONDITION ANALYZED USES THE MAXIMUM AIRFLOW PROVIDED TO THE ZONE DURING THE HEATING OR COOLING MODE, WHICHEVER IS BEING ANALYZED. <br />2. SYSTEM VENTILATION EFFICIENCY IS EQUAL TO THE LOWEST ZONE VENTILATION EFFICIENCY OF ALL ROOMS SERVED BY THE UNIT. <br />3. SEE UNIT EQUIPMENT SCHEDULE FOR ACTUAL OUTSIDE AIR SETPOINT FOR BALANCING; WHICH WILL MEET OR EXCEED THE MINIMUM REQUIREMENT NOTED HEREIN. <br />Unit Outside Airflow Balance Setpoint [cfm] 80 <br />Unit Meets IMC Requirements Yes <br />PgeGNunEx'.-NanEx. <br />2024906.011 <br />0rewn ar <br />MSK <br />Iwi. on.: <br />MARCH 27. 2024 <br />