My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1321 COLBY AVE 8TH FLOOR 2024-12-31
>
Address Records
>
COLBY AVE
>
1321
>
8TH FLOOR
>
1321 COLBY AVE 8TH FLOOR 2024-12-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/31/2024 1:06:05 PM
Creation date
12/13/2024 7:35:35 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
1321
Tenant Name
8TH FLOOR
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
117
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TrueAlarm Sensor Bases and Accessories rey-Mm R. M. <br /> TrueAlarm sensor bases contain integral addressable <br /> electronics that constantly monitor the status of the <br /> Base mounted address selection: detachable photoelectric or heat sensors.Each sensor's <br /> • Address remains with its programmed location output is digitized and transmitted to the system fire alarm <br /> • Accessible from front(DIP switch under sensor) <br /> control panel every four seconds. <br /> General features: <br /> • Automatic identification provides default sensitivity when Since TrueAlarm sensors use the same base,different <br /> substituting sensor types sensor types can be easily interchanged to meet specific <br /> • Integral red LED for power-on(pulsing),or alarm or trouble location requirements. This feature also allows intentional <br /> (steady on) sensor substitution during building construction.When <br /> • Locking anti-tamper design mounts on standard outlet box conditions are temporarily dusty,instead of covering the <br /> • Magnetically operated functional test smoke sensors(causing them to be disabled),heat sensors <br /> may be installed without reprogramming the control <br /> panel.Although the control panel will indicate an <br /> 4098-9792,Standard Sensor Base incorrect sensor type,the heat sensor will operate at a <br /> default sensitivity providing heat detection for building <br /> 4098-9789,Sensor Base with wired connections for: protection at that location. <br /> • 2098-9808 Remote LED alarm indicator or 4098-9822 relay <br /> (relay is unsupervised and requires separate 24 VDC) • • <br /> Supervised Relay Bases (not compatible with 2120 CDT): <br /> • 4098-9791,4-Wire Sensor Base,use with remote or Electrical Box Requirements:(boxes are by others) <br /> locally mounted 2098-9737 relay,requires separate 24 VDC Without relay in the box:4"octagonal or 4"square,1-1/2"deep; <br /> • 4098-9780,2-Wire Sensor Base,use with remote or single gang,2"deep <br /> locally mounted 4098-9860 relay,no separate power With relay in the box:4"octagonal or 4"square,1-1/2"deep, <br /> required with 1-1/2"extension ring <br /> • Supervised relay operation is programmable and can be 4"(102 mm)Square Box 4"(102 mm)Octagonal Box <br /> manually operated from control panel <br /> Surface mount reference <br /> • Includes wired connections for remote LED alarm indicator <br /> or 4098-9822 relay(relay is unsupervised and requires <br /> separate 24 VDC) C { C C <br /> • • • • <br /> 1-1/2"(3t1F <br /> 2098-9737, Remote or local mount supervised relay: minimum box depth Flush mount reference,mount even with final <br /> • DPDT contacts for resistive/suppressed loads,power limited surface,or with up to 1/4"(6.4 mm)maximum recess <br /> rating of 3 A @ 28 VDC;non-power limited rating of 3 A <br /> @ 120 VAC(requires external 24 VDC coil power) (mounts in Supervised Relay in base electrical <br /> Relay(mounts <br /> (mounts in base electrical box or in base electrical box) <br /> 4098-9860, Remote or local mount supervised relay: remotely) <br /> • SPDT dry contacts,power limited rating of 2 A @ 30 VDC, <br /> resistive;non-power limited rating of 0.5 A @ 125 VAC, <br /> resistive Relay Size: 2-1/2"X 1-1/2"X 1- <br /> 4098-9822, LED Annunciation Relay: (3.75 in 3)(64 mm X 38 mm X 25.4 mm) <br /> • Activates when base LED is on steady,indicating local <br /> alarm or trouble 4098-9860 Supervised Relay(mounts in base <br /> • DPDT contacts for resistive/suppressed loads ower limited electrical box or remotely; X 8 X 1 X 11/32" <br /> >p (1 in )(60.4 mm X 31.8 mm <br /> X8.6mm) <br /> rating of 2 A @ 28 VDC;non-power limited rating of <br /> 1/2 A @ 120 VAC,(requires external 24 VDC coil power) NOTE:Review total wire count,wire size,and accessories being <br /> 4098-9832,Adapter plate: wired to determine required box volume. <br /> • Required for surface or semi-flush mounting to 4"square <br /> electrical box and for surface mounting to 4"octagonal box ��' s-3/s"(1s2 mm) <br /> • Can be used for cosmetic retrofitting to existing 6-3/8" f 4098-9832 Adapter Plate,required for <br /> diameter base product 1/4" mounting to surface mounted boxes <br /> 2098-9808, Remote red LED Alarm (6.4 mm) and 4"square flush box <br /> Indicator: i 4-7/8"(124 mm) <br /> • Mounts on single gang box(shown in 15/16" <br /> illustration to right) ALARM (24 mm) 0 <br /> O LL <br /> TrueAlarm Bases <br /> 9351mplex 4098-9780,4098-9789,4098-9791,&4098-9792 <br /> 2 S4098-0019-23 8/2017 <br />
The URL can be used to link to this page
Your browser does not support the video tag.