Laserfiche WebLink
TrueAlarm Sensors <br /> Rate-of-rise temperature detection is selectable at the <br /> control panel for either 15'F(8.3°C)or 20'F(11.V C) <br /> Sealed against rear air flow entry per minute.Fixed temperature sensing is independent of <br /> Interchangeable mounting rate-of-rise sensing and programmable to operate at <br /> EMI/RFI shielded electronics 135'F(57.2°C)or 155'F(68'Q.The 4098-9734 <br /> Heat sensors: sensor provides an additional 190'F(88'C)set point. <br /> • Selectable rate compensated,fixed temperature In a slow developing fire,the temperature may not <br /> sensing with or without rate-of-rise operation increase rapidly enough to operate the rate-of-rise feature. <br /> • Rated spacing distance between sensors: However,an alarm will be initiated when the temperature <br /> Fixed Temp. UL&ULC FM Spacing,Either Fixed reaches its rated fixed temperature setting. <br /> Setting Spacing Temperature Setting TrueAlarm heat sensors can be programmed as a utility <br /> 135'F/190'F` 60 ft x 60 ft 20 ft x 20 ft(6.1 m)for fixed device to monitor for temperature extremes in the range <br /> (57.2°C/88°C) (18.3 m) temperature only;RTI=Quick from 32'F to 155'F(0'C to 68'C).This feature can <br /> 50 ft x 50 ft(15.2 m)for fixed provide freeze warnings or alert to HVAC system <br /> 155'F 40 ft x 40 ft temperature with either <br /> (68°C) (12.2 m) rate-of-rise selection;RTI=Ultra problems.Refer to specific panels for availability. <br /> Fast <br /> *Note:190'F(88'C)ratings apply only to the 4098-9734 sensor. <br /> -7/8"(124 mm <br /> Smoke Sensors: II�LED status indicator <br /> • Photoelectric technology sensing 2-3/8" <br /> • 360'smoke entry for optimum response (60 mm) <br /> • Built-in insect screens <br /> TrueAlarm photoelectric sensors use a stable,pulsed <br /> infrared LED light source and a silicon photodiode 4098-9733 Heat Sensor with Base <br /> receiver to provide consistent and accurate low power <br /> smoke sensing. Seven levels of sensitivity are available �a/8°(124 mm) <br /> for each individual sensor,ranging from 0.2%to 3.7%per <br /> foot of smoke obscuration. Sensitivities of 0.2%,0.5%, LED status indicator <br /> and 1%are for special applications in clean areas. 2-3/8" <br /> Standard sensitivities are 1.5%,2.0%,2.5%,3.0%,and (60 mm) <br /> 3.7%.Application type and sensitivity are selected and �® <br /> then monitored at the fire alarm control panel.* <br /> The sensor head design provides 360'smoke entry for <br /> optimum response to smoke from any direction.Due to its <br /> photoelectric operation,air velocity is not normally a 4098-9734 High Temperature Heat Sensor with Base <br /> factor,except for impact on area smoke flow. WARNING: In most fires, hazardous levels of smoke <br /> and toxic gas can build up before a heat detection <br /> -7/8"(124 mm) device would initiate an alarm. In cases where Life <br /> Safety is a factor,the use of smoke detection is highly <br /> LED status indicator recommended. <br /> 2-1/8" <br /> (54 mm) . • • <br /> 7 <br /> Sensor locations should be determined only after careful <br /> consideration of the physical layout and contents of the <br /> area to be protected.Refer to NFPA 72,the National Fire <br /> 4098-9714 Photoelectric Sensor with Base Alarm and Signaling Code.On smooth ceilings,smoke <br /> sensor spacing of 30 ft(9.1 m)may be used as a guide.* <br /> 1 • : • • 1 • : • *For detailed application information including sensitivity <br /> selection,refer to Installation Instructions 574-709. <br /> TrueAlarm heat sensors are self-restoring and provide rate <br /> compensated,fixed temperature sensing,selectable with <br /> or without rate-of-rise temperature sensing.Due to its <br /> small thermal mass,the sensor accurately and quickly <br /> measures the local temperature for analysis at the fire <br /> alarm control panel. <br /> 3 S4098-0019-23 8/2017 <br />