My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1321 COLBY AVE 8TH FLOOR 2024-12-31
>
Address Records
>
COLBY AVE
>
1321
>
8TH FLOOR
>
1321 COLBY AVE 8TH FLOOR 2024-12-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/31/2024 1:06:05 PM
Creation date
12/13/2024 7:35:35 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
1321
Tenant Name
8TH FLOOR
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
117
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TrueAlarm Sensors <br /> Rate-of-rise temperature detection is selectable at the <br /> control panel for either 15'F(8.3°C)or 20'F(11.V C) <br /> Sealed against rear air flow entry per minute.Fixed temperature sensing is independent of <br /> Interchangeable mounting rate-of-rise sensing and programmable to operate at <br /> EMI/RFI shielded electronics 135'F(57.2°C)or 155'F(68'Q.The 4098-9734 <br /> Heat sensors: sensor provides an additional 190'F(88'C)set point. <br /> • Selectable rate compensated,fixed temperature In a slow developing fire,the temperature may not <br /> sensing with or without rate-of-rise operation increase rapidly enough to operate the rate-of-rise feature. <br /> • Rated spacing distance between sensors: However,an alarm will be initiated when the temperature <br /> Fixed Temp. UL&ULC FM Spacing,Either Fixed reaches its rated fixed temperature setting. <br /> Setting Spacing Temperature Setting TrueAlarm heat sensors can be programmed as a utility <br /> 135'F/190'F` 60 ft x 60 ft 20 ft x 20 ft(6.1 m)for fixed device to monitor for temperature extremes in the range <br /> (57.2°C/88°C) (18.3 m) temperature only;RTI=Quick from 32'F to 155'F(0'C to 68'C).This feature can <br /> 50 ft x 50 ft(15.2 m)for fixed provide freeze warnings or alert to HVAC system <br /> 155'F 40 ft x 40 ft temperature with either <br /> (68°C) (12.2 m) rate-of-rise selection;RTI=Ultra problems.Refer to specific panels for availability. <br /> Fast <br /> *Note:190'F(88'C)ratings apply only to the 4098-9734 sensor. <br /> -7/8"(124 mm <br /> Smoke Sensors: II�LED status indicator <br /> • Photoelectric technology sensing 2-3/8" <br /> • 360'smoke entry for optimum response (60 mm) <br /> • Built-in insect screens <br /> TrueAlarm photoelectric sensors use a stable,pulsed <br /> infrared LED light source and a silicon photodiode 4098-9733 Heat Sensor with Base <br /> receiver to provide consistent and accurate low power <br /> smoke sensing. Seven levels of sensitivity are available �a/8°(124 mm) <br /> for each individual sensor,ranging from 0.2%to 3.7%per <br /> foot of smoke obscuration. Sensitivities of 0.2%,0.5%, LED status indicator <br /> and 1%are for special applications in clean areas. 2-3/8" <br /> Standard sensitivities are 1.5%,2.0%,2.5%,3.0%,and (60 mm) <br /> 3.7%.Application type and sensitivity are selected and �® <br /> then monitored at the fire alarm control panel.* <br /> The sensor head design provides 360'smoke entry for <br /> optimum response to smoke from any direction.Due to its <br /> photoelectric operation,air velocity is not normally a 4098-9734 High Temperature Heat Sensor with Base <br /> factor,except for impact on area smoke flow. WARNING: In most fires, hazardous levels of smoke <br /> and toxic gas can build up before a heat detection <br /> -7/8"(124 mm) device would initiate an alarm. In cases where Life <br /> Safety is a factor,the use of smoke detection is highly <br /> LED status indicator recommended. <br /> 2-1/8" <br /> (54 mm) . • • <br /> 7 <br /> Sensor locations should be determined only after careful <br /> consideration of the physical layout and contents of the <br /> area to be protected.Refer to NFPA 72,the National Fire <br /> 4098-9714 Photoelectric Sensor with Base Alarm and Signaling Code.On smooth ceilings,smoke <br /> sensor spacing of 30 ft(9.1 m)may be used as a guide.* <br /> 1 • : • • 1 • : • *For detailed application information including sensitivity <br /> selection,refer to Installation Instructions 574-709. <br /> TrueAlarm heat sensors are self-restoring and provide rate <br /> compensated,fixed temperature sensing,selectable with <br /> or without rate-of-rise temperature sensing.Due to its <br /> small thermal mass,the sensor accurately and quickly <br /> measures the local temperature for analysis at the fire <br /> alarm control panel. <br /> 3 S4098-0019-23 8/2017 <br />
The URL can be used to link to this page
Your browser does not support the video tag.