My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1321 COLBY AVE 8TH FLOOR 2024-12-31
>
Address Records
>
COLBY AVE
>
1321
>
8TH FLOOR
>
1321 COLBY AVE 8TH FLOOR 2024-12-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/31/2024 1:06:05 PM
Creation date
12/13/2024 7:35:35 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
1321
Tenant Name
8TH FLOOR
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
117
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Johnson <br /> * <br /> Controls <br /> Manufacturer's Recommendation <br /> 1) CONTRACTOR IS EXPECTED TO PULL AND TERMINATE ALL CONDUCTORS AND INSTALL ALL DEVICES FOR A COMPLETE AND <br /> OPERATING SYSTEM. <br /> 2) WHERE FAN SHUTDOWN,ELEVATOR RECALL OR SPECIAL AUXILIARY FUNCTIONS ARE REQUIRED,CONTRACTOR IS TO VERIFY WIRING <br /> REQUIREMENTS WITH THE JOHNSON CONTROLS FACTORY TECHNICIAN ASSIGNED TO THE PROJECT(IN MANY CASES,SPECIAL WIRING <br /> WILL NOT BE SHOWN ON THE DRAWINGS). <br /> 3) WHERE POSSIBLE,THE CONTRACTOR IS TO USE COLOR CODE FOR ALL WIRING. <br /> 4) SMOKE DETECTORS ARE NOT TO BE MOUNTED WITHIN 3 FEET OF AIR OUTLETS. <br /> 5) CONTRACTOR MUST NOT INSTALL SMOKE DETECTOR HEADS IN BASES OR DUCT HOUSING UNTIL FINAL CHECKOUT TIME TO ENSURE <br /> THAT DIRT OR DUST DOES NOT CONTAMINATE THE UNITS. DIRTY DETECTORS ARE NOT COVERED BY WARRANTY. <br /> 6) DO NOT POWER-UP SYSTEM UNTIL JOHNSON CONTROLS FACTORY TECHNICIAN IS PRESENT. <br /> 7) A SEPARATE GROUND(ISOLATION FROM CONDUIT GROUND)MUST BE PULLED TO ALL CABINETS. <br /> 8) LOADS GREATER THAN 10 AMPS(FOR AUXILIARY FUNCTIONS)ARE NOT ALLOWED IN THE SAME CONDUIT AS FIRE ALARM. <br /> 9) CONTRACTOR IS TO ENSURE THAT ALL WIRING AND SHIELDS ARE FREE OF SHORTS,GROUNDS AND OPENS. <br /> 10) UNDERGROUND WIRING MUST MAINTAIN ONE MEGAOHM,20F RESISTANCE TO GROUND. <br /> 11) ANY MANUFACTURER'S RECOMMENDATION IN CONFLICT WITH ENGINEERING DRAWINGS OR SPECIFICATIONS SHALL BE BROUGHT TO <br /> THE ATTENTION OF THE ENGINEER FOR CLARIFICATION. CONTRACTOR SHALL ADVISE JOHNSON CONTROLS OF ANY CHANGES. <br /> 12) PROTECTIVE COVERS ON SMOKE DETECTORS ARE NOT TO BE REMOVED UNTIL OWNERS ACCEPTANCE OF THE SYSTEM. (PREVENTS <br /> CONTAMINATION OF SMOKE CHAMBER). <br /> 13) IT IS THE CONTRACTOR'S RESPONSIBILITY TO REQUEST THE STATE OR LOCAL FIRE MARSHAL TO BE ON SITE FOR FINAL ACCEPTANCE <br /> AND CHECK OUT IF REQUIRED. <br /> 14) IT IS THE CONTRACTOR'S RESPONSIBILITY TO INVENTORY ALL EQUIPMENT RECEIVED FROM JOHNSON CONTROLS AGAINST THE <br /> CONTRACT DOCUMENTS AND REPORT ANY DISCREPANCIES WITHIN THIRTY(30)DAYS OR JOHNSON CONTROLS WILL ASSUME THE <br /> ORDER TO BE ACCURATE AND COMPLETE. <br /> a) "NOTE: IN THE EVENT OF DISCREPANCIES IN THE NUMBER OF DEVICES SUPPLIED,THE FOLLOWING JOHNSON CONTROLS <br /> POLICY WILL APPLY: <br /> i) TOO FEW DEVICES: IF THE DEVICE IS SHOWN ON THE CONTRACT DOCUMENTS AND HAS NOT BEEN ADDED AS A RESULT <br /> OF A POST BID ADDITION OR CHANGE ORDER,JOHNSON CONTROLS WILL SUPPLY THE DEVICE AT NO CHARGE TO THE <br /> CONTRACTOR OR END USER PER JOHNSON CONTROLS'S CONTRACT OBLIGATIONS. <br /> ii) TOO MANY DEVICES: IF THE DEVICE SHOWN IS EXTRA,DUE TO A POST BID ADDITION OR CHANGE ORDER;IT REMAINS THE <br /> PROPERTY OF THE CONTRACTOR OR END USER. IF THE DEVICE IS EXTRA DUE TO AN ERROR IN QUANTITIES SUPPLIED, <br /> THE DEVICE MUST BE RETURNED TO JOHNSON CONTROLS. NO CREDIT WILL BE ISSUED FOR THE RETURN OF EXTRA <br /> EQUIPMENT ABOVE THE QUANTITIES GIVEN IN THE CONTRACT DOCUMENTS. <br /> 15) OWNERS PRESENCE FOR FINAL DEMONSTRATION AND ACCEPTANCE. <br /> Fire,Security,Communications,Workforce Solutions,Sales Service <br /> Offices Representatives in Principle Cities throughout the World <br />
The URL can be used to link to this page
Your browser does not support the video tag.