My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
600 54TH ST SW D 2025-01-28
>
Address Records
>
54TH ST SW
>
600
>
600 54TH ST SW D 2025-01-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/28/2025 2:15:05 PM
Creation date
12/16/2024 12:00:53 PM
Metadata
Fields
Template:
Address Document
Street Name
54TH ST SW
Street Number
600
Unit
D
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
187
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Fluential Building Air Leakage <br />(Blower Door) Test Results <br />n#: <br />i addressor lot number: <br />ZIP <br />:ond. Floor Area <br />Age Df house: <br />Source (circle nn <br />Results shall be reported as Air Changes per Hour at 50 Pascals (ACH50) and shall be calculated as follows: <br />ACH50 = (CFM50 x 60)/ Volume <br />Where: <br />CFM50 = Blower door fan flow at 50 Pascal pressure difference <br />Volume = Conditioned Floor Area of the housing unit x ceiling height <br />Blower Door Test Result: ACH50 <br />1`bJ CFM@50Pa <br />I certilly that these blower door <br />results are accurate and detennined using standard IndrYY protocol: . <br />Company Name: <br />u i aw i <br />Technician: <br />SG� <br />Technician Signature: <br />EEEEEE4 <br />Date: <br />Phone Number: <br />e;6o 3;7,'-1Z3rd <br />2018 WSEC reference: <br />R402A.1.2 Testing. The building or dwelling unit shall be tested and verified as havingan air leakage rate of not <br />exceeding 5 ACH50. Testing shall be conducted with a blower door at a pressure of0.2 inches w.g. (50 Pascals). <br />Forthis test only, the volume of the home shall be the conditioned floor areaonft (m2) multiplied by&5 feet(2.6 m). <br />Where required by the code official, testing shall be conducted by an approved third party. A written <br />report of the results of the test shall be signed by the party conducting the test and provided to the code <br />official. Testing shall be performed at any time after creation of all penetrations of the building thermal <br />envelope. Once visual inspection has confirmed sealing (see Table R402.4.1.1), operable windows and <br />doors manufactured by small business shall be permitted to be seated off at the frame prior to the test. <br />During testing: <br />1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended <br />weatherstripping or other infiltration control measures; <br />2. Dampers including exhaust, Intake, makeup air, backdraft and flue shall be closed, but not sealed beyond <br />intended infiltration control measures; <br />3. Interior doors, if Installed at the time of the test, shall be open. Access hatches to conditioned crawl spaces <br />and conditioned attics shall be open; and heat recovery veilators sealed; <br />4. Exterior and coolingr continuous <br />in <br />stalled iion systems the time ofthe test, shall a turned off and shall6e dosed, <br />5, Heating <br />6 Supply and return registers, isYstemsff Installed at the time of the test, shall e fully open. <br />q <br />
The URL can be used to link to this page
Your browser does not support the video tag.