My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3301 SEAWAY BLVD TERRA POWER 2025-01-06
>
Address Records
>
SEAWAY BLVD
>
3301
>
TERRA POWER
>
3301 SEAWAY BLVD TERRA POWER 2025-01-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/6/2025 11:46:10 AM
Creation date
12/17/2024 9:48:20 AM
Metadata
Fields
Template:
Address Document
Street Name
SEAWAY BLVD
Street Number
3301
Tenant Name
TERRA POWER
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
81
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
#r"V:F <br /> MacDonald-Miller <br /> FACILITY SOLUTIONS <br /> Energy Recovery Unit <br /> PROJECT: Terra Power Bldg B Laser Lab DATE: 6/25/2024 <br /> LOCATION: Everett,WA CONTACT: Mikhail Gadomskiy <br /> PROJECT#: 72247025 <br /> SYSTEM/UNIT: ERV-01/VAV-1-1 Tested By: Mikhail Gadomskiy <br /> Date: 6/20/2024 <br /> Unit Data Term Box Test Data <br /> Manufacturer Nailor Max Setpoint 1710 <br /> Model Number D30RE Min Setpoint 700 <br /> Serial Number 783463-.01 <br /> Box Inlet Size 12" Term Box Test Data <br /> K Factor 1 Design Actual <br /> Primary Max CFM 1710 CFM 1730 CFM <br /> Primary Min CFM 700 CFM 710 CFM <br /> Electric Heat <br /> Rated KW 6 KW <br /> Design DT 27 Deg F <br /> Measured DT 26.5 Deg F <br /> Design CFM 700 CFM <br /> Measured CFM 705 CFM <br /> ERV-01/VAV-1-1 Supply Outlet Summary <br /> System/Unit Type of Outlet Size AK Design Prelim %Pre Final %Final T/O <br /> Reading Type Factor Reading Reading Reading <br /> Outlet-01 Flowhood CD 16" 1 855 745 87 870 102 T <br /> Outlet-02 Flowhood CD 16" 1 855 690 81 860 101 O <br /> Totals: - - - 1710 1435 84 1730 101 - <br /> SYSTEM/UNIT: ERV-01/VAV-M1 Tested By: Mikhail Gadomskiy <br /> Date: 6/20/2024 <br /> Unit Data Term Box Test Data <br /> Manufacturer Nailor Max Setpoint 300 <br /> Model Number D30RE Min Setpoint 300 <br /> Serial Number 783463-2.01 <br /> Box Inlet Size 6" Term Box Test Data <br /> K Factor 1 Design Actual <br /> Primary Max CFM 300 CFM 295 CFM <br /> Primary Min CFM 300 CFM 295 CFM <br /> Electric Heat <br /> Rated KW 3 KW <br /> Design DT 31.5 Deg F <br /> Measured DT 32.1 Deg F <br /> Design CFM 300 CFM <br /> Measured CFM 295 CFM <br /> ERV-01/VAV-M1 Supply Outlet Summary <br /> System/Unit Type of Outlet Size AK Design Prelim %Pre Final %Final T/O <br /> Reading Type Factor Reading Reading Reading <br /> Outlet-01 Flowhood CD 101, 1 300 380 127 295 98 T/O <br /> Totals: - 300 380 1 127 295 98 - <br /> MacDonald-Miller <br /> Page 10 of 14 <br />
The URL can be used to link to this page
Your browser does not support the video tag.