My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8717 7TH AVE SE 2024-12-31
>
Address Records
>
7TH AVE SE
>
8717
>
8717 7TH AVE SE 2024-12-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/6/2025 1:17:49 PM
Creation date
12/17/2024 10:40:30 AM
Metadata
Fields
Template:
Address Document
Street Name
7TH AVE SE
Street Number
8717
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
109
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IVNEUDORFER �+ <br /> ENGINEERS p E B� <br /> •N Cter-a COMDAN, C.6 <br /> Fan Coil Unit - DX <br /> PROJECT: St. Mary Magdalen Elementary HVAC Project DATE: 8/15/2024 <br /> LOCATION: Everett,WA CONTA Kami Valentine <br /> PROJECT#: 2024-0871 AUTHO <br /> OPT -Mechanical - FCU-01 <br /> Verification Response Notes By Date/Time <br /> 1 Condensate Pump is operating NA KV 8/8/24 8:59 <br /> without any issues <br /> 2 Fan belt tension&condition good NA KV 8/8/24 8:59 <br /> 3 Fan have no unusual noise or Pass KV 8/8/24 8:59 <br /> vibration <br /> 4 Fan rotation correct Pass KV 1 8/8/24 8:59 <br /> 0.1 PreFunctional Performance - FCU-01 Functional Performance Test <br /> Verification Response Notes By Date/Time <br /> 1 PFPT Completed Pass KV 8/7/24 10:58 <br /> 2 IStartup Completed Pass KV 8/8/24 9:00 <br /> 1.0 Setpoints -FCU-01 Functional Performance Test <br /> Verification Response Notes By Date/Time <br /> 1 Building occupancy schedule= <br /> Monday to Sunday,6:OOAM to Pass KV 8/8/24 8:59 <br /> 6:OOPM <br /> 2 Heating/Cooling Temperature <br /> Setpoint=adjustable between 670F Pass KV 8/8/24 8:59 <br /> to 76°F <br /> 3 Occupied Heating/Cooling <br /> Temperature Setpoint=71 OF to <br /> 73°F. Unccupied Heating/Cooling Pass KV 8/8/24 8:59 <br /> Temperature Setpoint=650F to 80OF <br /> 1.1 As-Found Conditions - FCU-01 Functional Performance Test <br /> Verification Response Notes By Date/Time <br /> 1 JAs Found Room Temp 72°F KV 8/8/24 9:00 <br /> 2.0 Heating -FCU-01 Functional Performance Test <br /> Verification Response Notes By Date/Time <br /> 1 'TEST PROCEDURE,Set the <br /> heating setpoint to 50F above zone <br /> temperature <br /> 1. <br /> 2 Unit is ON in Heating mode Pass KV 8/7/24 10:58 <br /> 3 DAT increases.Record DAT 94°F KV 8/7/24 10:58 <br /> 2.1 Cooling - FCU-01 Functional Performance Test <br /> Verification Response Notes By Date/Time <br /> 1 TEST PROCEDURE,Set the cooling <br /> setpoint to 50F below zone <br /> temperature <br /> 2 Unit is ON in Cooling mode Pass KV 8/7/24 10:58 <br /> 3 DAT decreases.Record DAT 63°F KV 1 8/7/24 10:58 <br />
The URL can be used to link to this page
Your browser does not support the video tag.