My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2121 W CASINO RD WSIPC 2024-12-30
>
Address Records
>
W CASINO RD
>
2121
>
WSIPC
>
2121 W CASINO RD WSIPC 2024-12-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/30/2024 1:10:59 PM
Creation date
12/17/2024 11:04:44 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
2121
Tenant Name
WSIPC
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GLUMAC <br /> ATE RA TECH-.1— <br /> engineer 8 for a sustainable future- <br /> 1601 Fin Ave.,S-2210 <br /> W 98101 <br /> vn,*M,n,g,,: <br /> T.206.262.1010 <br /> Frrz <br /> Protect Manager:DeNayne Glenn <br /> Job.No.:24U500138 <br /> I <br /> I <br /> Mechanical <br /> - - NOT IN SCOPE <br /> Client <br /> 2 <br /> E3.1 <br /> W S I P C <br /> Inspired by education. <br /> Empowered by technology." <br /> 'Project <br /> WSIPC Cooling <br /> Tower Replacement <br /> 2121 W.Casino Road, <br /> Everette,WA <br /> LEVEL 1 - FLOOR PLAN - POWER & SIGNAL <br /> 1 SCALE:1/8"=T-0" <br /> DONG Lf <br /> 'r w°t eAsylN G <br /> Fey co <br /> m x <br /> EXTERIOR COOLING SHEET NOTES KEYED NOTES cc) 211612024 <br /> TOWER FENCE A. COORDINATE EXACT MECHANICAL EQUIPMENT LOCATIONS AND 1. REFER TO MANUFACTURER'S INSTALLATION WIRING DIAGRAM, <br /> REQUIREMENTS WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN. PROVIDE ONE POINT CONNECTION TO COOLING TOWER DRIVE PANEL, ©2014-GLUMAC ALL RIGHTS RESERVED <br /> COORDINATE CONDUIT REQUIREMENTS FOR ALL HVAC EQUIPMENT WITH REUSE AND CLEAN EXISTING CONDUITS FROM PANELBOARD SOURCE THESE DRAWINGS ARE THE PROPERTY OF <br /> CONTROLS CONTRACTOR. TO DRIVE PANEL LOCATION,EXTEND CONDUIT AS REQUIRED IF THE GLUMAC ARE NOT TO BE <br /> NEW DRIVE PANEL LOCATION IS MOVED,PROVIDE NEW WIRING TO <br /> B. ELECTRICAL CONTRACTOR TO PROVIDE ALL NECESSARY POWER REPLACE AND SIZE MATCH EXISTING CONDUCTORS THROUGH USED OR REPRODUCED IN ANY MANNER, <br /> CONNECTIONS TO ALL FIRE PROTECTION SYSTEM EQUIPMENT AS SHOWN ON EXISTING CONDUIT TO NEW DRIVE PANEL.NEW COOLING TOWER IS WITHOUT PRIOR WRITTEN PERMISSION <br /> SEPARATE DESIGN BUILD FIRE PROTECTION DRAWINGS SET,PROVIDE SAME MODEL AS EXISTING ONE,REUSE THE EXISTING 5OA-3P CIRCUIT <br /> ALLOWANCE IF THE INFORMATION IS NOT AVAILABLE AT BID PHASE. BREAKER INSIDE THE PANEL. <br /> Revisions <br /> C. REFER TO ONE LINE DIAGRAM FOR ADDITIONAL INFORMATION ON NAMED 2. ALL MISC.120V POWER CONNECTIONS TO PUMPS,VALVES,HEATERS <br /> COOLING ELECTRICAL EQUIPMENT SHOWN. AND CONVENIENCE RECEPTACLES WITHIN THE FENCE,WHICH # Description Date <br /> TOWER SERVING EXISTING COOLING TOWER WERE FED FROM THIS <br /> D. REFER TO ARCHITECTURAL FLOOR PLANS,INTERIOR ELEVATIONS AND DETAIL PANELBOARD,REUSE THE EXISTING CIRCUIT BREAKERS AND <br /> DRAWINGS PRIOR TO ROUGH-IN FOR EXACT LOCATION OF RECEPTACLES, CONDUITS TO FEED NEW MISC.EQUIPMENT,REPLACE EXISTING <br /> FLOOR BOXES AND OUTLETS.INFORM ENGINEER OF CONFLICTS. CONDUCTORS WITH NEW CONDUCTORS.PROVIDE(1)NEW 20A-1P <br /> SECTION#3 CIRCUIT FROM THIS PANELBOARD TO FEED(2)(NEW)120V BYPASS <br /> E. FLOOR PLANS ARE DIAGRAMMATIC.CONTRACTOR SHALL COORDINATE EXACT ISOLATION VALVES WHICH ARE INSTALLED AS PART OF THIS PROJECT, SHEET TITLE: <br /> LOCATIONS WITH ARCHITECTURAL DRAWINGS AND FIELD DETERMINE EXACT SEE MECHANICAL DETAILS FOR ADDITIONAL INFORMATION.. LEVEL 1 - <br /> CONDUIT,PULL BOX,AND ROUTING REQUIREMENTS. <br /> 3. AFTER EXISTING COOLING TOWER IS REMOVED,PROVIDE TEMPORARY POWER AND <br /> SECTION#2 F. CIRCUIT SIZES ARE NOT SHOWN ON THE PLANS.CONTRACTOR SHALL USE POWER FED FROM EXISTING COOLING TOWER MAIN POWER CIRCUIT <br /> CIRCUIT SIZES INDICATED IN NOTES OR RESPECTIVE SCHEDULES(PNL,MCC, BREAKER FOR TEMPORARY COOLING TOWER USE,COORDINATE WITH <br /> EXISTING MSB; ETC.)AND INFORMATION IN THE FEEDER AND BRANCH CIRCUIT SCHEDULES. MECHANICAL CONTRACTOR ON LOCATION OF TEMPROARY TOWER SIGNAL PLAN <br /> DURING CONSTRUCTION. <br /> G. INSTALL ALL EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS AND <br /> PULL INSTRUCTIONS.THESE DRAWINGS ARE DIAGRAMMATIC. <br /> SECTION <br /> 1 --- H. PROVIDE SPECIAL RECEPTACLES THAT MATCH CORD AND CAP PROVIDED WITH <br /> EQUIPMENT,UON.USE ADJACENT NEMA CONFIGURATION NUMBER,IF ONE IS <br /> SHOWN. DRAWN BY:Author <br /> \\\ \\ I. ALL NEW RACEWAYS AND CONDUCTORS SHALL BE INSTALLED CONCEALED. CHECKED BY:Checker <br /> EX.DRIVE PANEL RPPI- (EEX EXISTING 1-W A <br /> EX.DISC.SW. J. WHERE BRANCH CIRCUIT WIRE SIZES ARE NOT EXPLICITLY CALLED OUT, <br /> BRANCH CIRCUIT WIRE SIZES FOR EACH NEW OR MODIFIED CIRCUIT SHALL BE <br /> EX.VFD BASED ON THE CIRCUIT BREAKER INDICATED ON THE ELECTRIAL PANEL SHEET <br /> SCHEDULES,PROVIDE THE FOLLOWING: <br /> a. 20A-IP C.B.20.1 BRANCH CIRCUIT, <br /> b. 20A-2P C.B.20.2 BRANCH CIRCUIT, <br /> c. 20A-3P C.B.20.3 COPPER FEEDER, <br /> d. 3OA-iP C.B.30.1 BRANCH CIRCUIT, NORTH <br /> e. 30A-2P C.B.30.2 BRANCH CIRCUIT, <br /> LEVEL 1 ENLARGED ELEC ROOM <br /> f. 30A-3P C.B.30.3 COPPER FEEDER. <br /> - <br /> JOB NO.24US00135 <br /> Construction Documents 2/19/2024 <br /> As <br /> Indicated <br />
The URL can be used to link to this page
Your browser does not support the video tag.