Laserfiche WebLink
ROOF ROOF <br /> -ROOF - - - - - - - - -- SHEET NOTES GLUMAC <br /> ATE RA TECH COMPANY <br /> LEVEL 2 LEVEL 2 A. ALL CIRCUITS ARE 3 PHASE,UNLESS OTHERWISE NOTED. engineers fora Sustainable future- <br /> B. ITEMS SHOWN ARE ALL EXISTING UNLESS NOTED OTHERWISE.NEW 1601 Fin Ave.,S-2210 <br /> EQUIPMENT WILL IDENTIFIED AS'(NEW)". Sease.WA 96101 <br /> T-6.262.101 m <br /> T,,Jm 62.1010 <br /> I I C. ALL COMPONENTS SHALL BE FULLY RATED.SERIES RATED IS NOT Protect Manager:DeNayne Glenn <br /> (NEW) ALLOWED. Job.Ne. NUS00135 <br /> 60A-3P (NEW) VFD BY DIV.23 D. PROVIDE CABLE SUPPORTS PER NEC 300.19(A). <br /> (EXJ PNL 6Y DIV.26 DRIVE <br /> II LP1-W II ------------------ --- VFD <br /> 10- Ir — PANEL <br /> I EXISTING CONDUIT TO I BY <br /> REMAIN,REPLACE <br /> —JI EXISTINGCONDUCTORS OTHERS (NEW) <br /> EXISTING FEEDER WITH NEW WIRING,SIZE COOLINGTOWER <br /> TO MATCH EXISTING. CONNECTION <br /> ----------------------------_-- -----------------------T-r-�--, <br /> PSR.LP1-E ELEVATOR PNL LP2-W I PNL PP-E PNL-GM �I PSR-64-0 75KVA-PXFR PNL PPL PNL PP-W LEVEL <br /> 1 ODAI 100A I 100A1 1ODA b 200A d 100Ad 600A" 00A 1 100A1 100A d 400A! 200A1 I <br /> 3P ) 3P ) 3P ) 3P ) 3P ) 3P ) III 3P ) 3P ) 3P ) 3P ) 3P ) 3P ) <br /> li --TL---I---L---L--- P---- q— —p--- ----p--- --- --�—r <br /> Client <br /> SECTION#3-600A SECTION#2-1200A PULL SECTION I I <br /> II---------------------------- -----------------------L------I <br /> EXISTING MSB 1 <br /> LEVEL 1 EXISTING MAIN ELEC ROOM LEVEL 1 <br /> t�/ P C <br /> I EXISTING UTILITY SERVICE C I <br /> � - ------------- - - - - - - - - -----------LL--------------- YYJ <br /> Inspired by education. <br /> Empowered by technology.- <br /> Project <br /> WSIPC Cooling <br /> Tower Replacement <br /> 2121 W.Casino Road, <br /> Everette,WA <br /> PANEL: EXISTING LP1-W(BEFORE) PANEL: EXISTING LP1-W(AFTER) <br /> VOLTAGE:480Y/277V,3PH,4W NEMA RATING:Type 1 VOLTAGE:480Y/277V,3PH,4W NEMA RATING:Type 1 <br /> MOUNTING:SURFACE INTEGRAL SPD:No MOUNTING:SURFACE INTEGRAL SPD:No <br /> BUS RATING:100 A ISOL GROUND BAR:No BUS RATING:100 A ISOL GROUND BAR:No <br /> MAIN AMPS:100 A MLO FEED-THRU LUGS:No LOCATION: MAIN AMPS:100 A MLO FEED-THRU LUGS:No LOCATION: <br /> AIC RATING:14KA DOUBLE-LUGS:No SUPPLY FROM:EXISTING MSB AIC RATING:14KA DOUBLE-LUGS:No SUPPLY FROM: <br /> CKT TRIP POLE DESCRIPTION TYPE A(kVA) I B(kVA) C(kVA) TYPE DESCRIPTION POLE TRIP CKT CKT TRIP POLE DESCRIPTION TYPE A(kVA) B(kVA) C(kVA) TYPE DESCRIPTION POLE TRIP CKT <br /> 1 - 1 SPACE -- - - -- SPACE 1 -- 2 1 - 1 SPACE -- - -- -- SPACE 1 -- 2 <br /> 3 9.7 0 -- LIGHTS-TRAINING LAB,LUNCH ROOM A 1 20 A 4 3 9.7 0 -- LIGHTS-TRAINING LAB,LUNCH ROOM A 1 20 A 4 DONG <br /> 5 50 A 3 EXISTING COOLING TOWER VFD M 9.7 0 -- LIGHTS-CONSTELLATION A&B A 1 20 A 6 5 50 A 3 NEW COOLING TOWER VFD M 9.7 0 -- LIGHTS-CONSTELLATION A&B A 1 20 A 6 ,.�1 ,oF WAgytL,/lrI <br /> 7 9.7 0 -- LIGHTS-COPIER ROOM A 1 20 A 6 7 9.7 0 -- LIGHTS-COPIER ROOM A 1 20 A 8 Ae �o <br /> 9 20 A 1 LIGHTS-STORE ROOM A 0 0 LIGHTS-ELECTRICAUMECH.ROOM A 1 20 A 10 9 20 A 1 LIGHTS-STORE ROOM A 0 0 LIGHTS-ELECTRICAUMECH.ROOM A 1 20 A 10 <br /> 11 0 0 - SPARE 1 20A 12 11 0 0 - SPARE 1 20A 12 <br /> 13 30 A 3 SPARE -- 0 — -- SPACE 1 14 13 30 A 3 SPARE -- 0 -- -- SPACE 1 14 <br /> 15 0 — -- SPACE 1 16 15 0 — -- SPACE 1 16 is <br /> 17 — 1 SPACE -- -- — -- SPACE 1 -- 18 17 — 1 SPACE -- -- — -- SPACE 1 -- 18 <br /> 19 — 1 SPACE -- — -- -- SPACE 1 -- 20 19 — 1 SPACE -- — -- -- SPACE 1 -- 20 2/16/2024 <br /> 21 — 1 SPACE -- -- — -- SPACE 1 -- 22 21 — 1 SPACE -- -- — -- SPACE 1 -- 22 <br /> 23 — 1 SPACE -- -- — -- SPACE 1 -- 24 23 — 1 SPACE -- -- L <br /> -- SPACE 1 -- 24 <br /> 25 — 1 SPACE -- — — -- SPACE 1 -- 26 25 — 1 SPACE -- — -- -- SPACE 1 -- 26 ©2014-GLUMAC ALL RIGHTS RESERVED <br /> 27 — 1 SPACE -- -- — -- SPACE 1 -- 28 27 — 1 SPACE -- -- — -- SPACE 1 -- 28 THESE DRAWINGS ARE THE PROPERTY OF <br /> 29 GLUMAC ARE NOT TO BE <br /> USED 30 OR REPRODUCED IN ANY MANNER, <br /> _ __ __ _ __ __ _ __ __ __ __ <br /> SPECIAL PANEL FEATURES 9.7 kVA 9.7 kVA 9.7 kVA CIRCUIT NOTES SPECIAL PANEL FEATURES 9.7 kVA 9.7 kVA 9.7 kVA CIRCUIT NOTES WITHOUT PRIOR WRITTEN PERMISSION <br /> A-EXISTING CIRCUIT TO REMAIN AS IS A-EXISTING CIRCUIT TO REMAIN AS IS <br /> (X)-EXISTING CIRCUIT TO BE REMOVED. (X)-EXISTING CIRCUIT TO BE REMOVED. <br /> Revisions <br /> LOAD TYPE CONNECTED DEMAND FACTOR DEMAND LOAD LOAD TYPE KEY PANEL TOTALS LOAD TYPE CONNECTED DEMAND FACTOR DEMAND LOAD LOAD TYPE KEY PANEL TOTALS # Description Date <br /> Motor 29.1 kVA 125% 36.37 kVA C=CONTINUOUS KVA AMPS Motor 29.1 kVA 125% 36.37 kVA C=CONTINUOUS KVA AMPS <br /> E=ELEVATOR TOTAL CONNECTED LOAD: 29.1 kVA 35 A E=ELEVATOR TOTAL CONNECTED LOAD: 29.1 kVA 35 A <br /> K=KITCHEN TOTAL DEMAND LOAD: 36.37 kVA 43.8 A K=KITCHEN TOTAL DEMAND LOAD: 36.37 kVA 43.8 A <br /> L=LIGHTING SPARE CAPACITY: 25% 25% L=LIGHTING SPARE CAPACITY: 25% 25% SHEET TITLE: <br /> M=MOTOR DESIGNED CAPACITY: 45.47 kVA 55 A M=MOTOR DESIGNED CAPACITY: 45.47 kVA 55 A ELECTRICAL <br /> MOTOR=LARGEST MOTOR MOTOR=LARGEST MOTOR 1-LINE <br /> N=NON-CONTINUOUS N=NON-CONTINUOUS <br /> R=RECEPTACLE R=RECEPTACLE DIAGRAM AND <br /> PANELBOARD <br /> SCHEDULES <br /> DRAWN BY:Author <br /> CHECKED BY:Checker <br /> SHEET <br /> E5.1 <br /> JOB NO.24US00135 <br /> Construction Documents 2/19/2024 <br />