2930 MAPLE ST 1 KAISER PERMANENTE 2025-01-24
>
Address Records
>
MAPLE ST
>
2930
>
KAISER PERMANENTE
>
2930 MAPLE ST 1 KAISER PERMANENTE 2025-01-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/24/2025 3:43:10 PM
Creation date
12/31/2024 1:14:31 PM
Metadata
Fields
Template:
Address Document
Street Name
MAPLE ST
Street Number
2930
Unit
1
Tenant Name
KAISER PERMANENTE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
312
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> SER <br /> RATING AND RETAINING UL D \ I ANEME <br /> CODE (TYP) ANGLE AND <br /> FASTENERS Project <br /> SEQUENCE OF OPERATION SMETAL LEEVE (TYP) Kaiser Permanente Everett <br /> BREAK AWAY Specialty Center <br /> CURTAIN DUCT <br /> DAMPER _ CONNECTION, 2930 MAPLE STREET <br /> TRANSFORMER EXHAUST FAN(TEF-1) WITH SEAL AIR— EVERETT,WA 98201 <br /> TWO THERMOSTATS WILL BE INSTALLED IN THE VAULT TO TURN THE FAN ON/OFF, ONE THERMOSTAT WILL POWER THE FAN ON IF THE ROOM REACHES 70-F AND CLOSURE TIGHT (TYP) <br /> OFF IF IT FALLS BELOW. THE OTHER FAN WILL POWER OFF THE UNIT THE FAN SHALL TURN OFF IF THE TEMPERATURE REACHES ABOVE 1407. THE SPRING Prepared for <br /> TEMPERATURE READINGS MUST BE ABOVE/BELOW THE REQUIRED LEVEL FOR 5 MINUTES FOR ACTIVATION/DEACTIVATION OF THE SYSTEM. DUCT ACCESS KAISER FOUNDATION <br /> FACTORY DOOR, SEE <br /> ALARM/MONITORING: COLLAR SPECIFICATIONS HEALTH PLAN, INC. <br /> CDC SHALL PROVIDE THE FOLLOWING POINTS FOR MONITORING/ALARMING: (TYP) FOR MINIMUM NATIONAL FACILITIES SERVICES <br /> SIZE POST OFFICE BOX 12916 <br /> FAN STATUS. FIRE OAKLAND,CA 94604 <br /> RATED <br /> THERMOSTAT WILL CONNECT DIRECTLY TO FANS FOR OPERATION. SEE ELECTRICAL FOR POWER. CON— <br /> STRUCTION, 6" 6" DUCT, REFER <br /> REFER <br /> GARAGE EXHAUST FANS(GEF-1,2,3,4) TO ARCH MAX MAX TO PLANS FOR <br /> GEF-1 UNIT WILL OPERATE 24 HOURS PER DAY, 7 DAYS PER WEEK. UPON A SUSTAINED HIGH READING FROM THE CO (25 PPM) OR NO2 (0.1 PPM) DETECTORS DRAWINGS (16" MAX IF FACTORY SIZES AND <br /> INSTALL THE GARAGE, GEF-2,3, 4 WILL TURN ON AND REMAIN ON UNTIL THE LEVELS FALL BELOW THE MONITOR'S SETPOINT. (TYP) SLEEVE INCLUDES LOCATIONS <br /> ACCESS DOOR) (TYP) <br /> ALARM/MONITORING: NOTES: <br /> CDC SHALL PROVIDE THE FOLLOWING POINTS FOR MONITORING/ALARMING: 1. INSTALL PER UL AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. <br /> FAN STATUS. 2. VERTICAL INSTALLATION SHOWN, HORIZONTAL INSTALLATION SIMILAR. <br /> 3. FIELD FABRICATED SLEEVE SHOWN, FACTORY SLEEVE WITH FACTORY <br /> CO/N20 LEVELS. ACCESS DOOR IS OPTIONAL. <br /> 4. NOT APPLICABLE FOR MOIST ENVIRONMENTS. <br /> I l Hellmuth,Obata&Kassabaum,Inc.CIRE DAMPER <br /> 1218 Third Avenue,Suite 1315 <br /> M2.1 SCALE:NONE Seattle,WA 98101 USA <br /> D DC POINTS LIST t+1 206 493 1771 f+1 206 493 1778 <br /> INPUT OUTPUT ALARMS d"nenn a intanantn P P y ighl.,pse.Ved <br /> SYSTEM DEVICE ANALOG DIGITAL ANALOG DIGITAL ANALOG I DIGITAL REMARKS <br /> In Association with <br /> TEF1 <br /> MOTORIZED DAMPER MOD X X <br /> ON/OFF AUX X X Mortenson <br /> Generel Contractor <br /> ROOM THERMOSTAT TS I X I I I I X I IWIRE UNIT T'STAT <br /> 10230 d, A98 33 Suite 300 <br /> '. ROOM THERMOSTAT TS X X WIRE UNIT T'STAT <br /> I{trklaud,WA98033 <br /> UEF-1 <br /> MOTORIZED DAMPER MOD X x <br /> ON/OFF AUX X % ConXtech,Inc <br /> Structural Fablicabr <br /> GIEF-W 6701 Koll Center Parkway,Suite 150 <br /> CURRENT RELAY CR X X PER FAN Pleasanton,CA94566 <br /> START/STOP S/S X % PER FAN <br /> MOTORIZED DAMPER MOD X X TWO TOTAL KPFF Consulting Engineers <br /> CIA+Structural Engineering <br /> CO2 MONITOR(TYP) AUX X X WIRE UNIT T'STAT 1601 Fffih A nue,Suite 1600 <br /> N20 MONITOR(TYP) AUX X X WIRE UNIT T'STAT Seattle,WA98101 <br /> ON/OFF AUX X X PER FAN <br /> Mazzetti <br /> MEP+FP Engineering <br /> 2013 4th A-,Suite 200 <br /> Seattle,WA98121 <br /> Key Plan <br /> N <br /> S <br /> .�2 <br /> Professional Scala <br /> sST <br /> av <br /> w <br /> r.� o <br /> rn z <br /> Ecsrt'�' r' <br /> ZONALG <br /> No. Description Data <br /> PERMIT SET 03/18/20 <br /> KP Project No: CAP020407 <br /> HOK Project No: <br /> Sheet Title' <br /> DETAILS AND <br /> CONTROLS <br /> original I.36.24.D. s�a on,ents ",s draw,n9 <br /> Sheet Number <br /> M2 . 1 <br />