ELECTRICAL SYMBOL SCHEDULE <br /> KAISER <br /> FWAI P MAN r E. <br /> DESIGNATION SYMBOLS POWER SYMBOLS ELECTRICAL GENERAL NOTES ABBREVIATIONS Project <br /> OCOLUMN LINE A ALL ELECTRICAL WORK SHALL COMPY WITH THE CURRENT APPROVED EDITION OF A.AMP AMPERE GFCI GROUND FAULT Kaiser- Permanente Everett <br /> THE NATIONAL ELECTRICAL CODE,AS ACCEPTED AND AMENDED BY LOCAL CIRCUIT INTERRUPTING Specialty Center <br /> ISIXM, FEEDER DESIGNATION TAG FUSED DISCONNECT SWITCH ORDINANCES. AC ALTERNATING CURRENT G,GND GROUND <br /> SWITCH XX/%X/XX=AMP SWITCH/POLES/AMP FUSE B. WHERE GROUNDED CONDUCTORS OF DIFFERENT SYSTEMS ARE INSTALLED IN THE ACT ABOVE COUNTER TOP GEN GENERATOR <br /> SAME RACEWAY,CABLE,BOX,AUXILIARY GUTTER,OR OTHER TYPE OF 2930 MAPLE STREET <br /> OKEY NOTE TAG HEAVY DUTY NON-FUSED DISCONNECT SWITCH ENCLOSURE,EACH GROUNDED CONDUCTOR SHALL BE IDENTIFIED BY SYSTEM AIC AMPERE INTERRUPTING CAPACITY IG ISOLATED GROUND. EVERETT,WA 98201 <br /> DETAIL REFERENCE BUBBLE a SWITCH XX/XX =AMP SWITCH/POLES PER NEC ARTICLE 200.E(D). MEANS OF IDENTIFICATION SHALL BE AFF ABOVE FINISHED FLOOR HID HIGH INTENSITY DISCHARGE <br /> PERMANENTLY POSTED AT EACH BRANCH CIRCUIT PANELBOARD. Prepared for <br /> A DETAIL NUMBER <br /> SM MANUAL MOTOR STARTER SWITCH WITH THERMAL OVERLOAD PROPERTIES C. PER NEC ART 210.5(C),UNGROUNDED CONDUCTORS OF MORE THAN ONE AFG ABOVE FINISHED GRADE HOA HAND -OFF-AUTO KAISER FOUNDATION <br /> Et. SHEET BEARING DETAIL NOMINAL VOLTAGE SYSTEM SHALL BE IDENTIFIED BY SYSTEM.PROVIDE MEANS <br /> VFD VARIABLE FREQUENCY DRIVE OF IDENTIFICATION AS REQUIRED PER THIS ARTICLE. ATS AUTOMATIC TRANSFER SWITCH HP HORSEPOWER HEALTH PLAN, INC. <br /> EF <br /> ATS AUTOMATIC TRANSFER SWITCH D. PER NEC ART 215.12,FEEDER IDENTIFICAITON IS REQUIRED WHEN MORE THAN AF FRAME RATING IN AMPERES HPF HIGH POWER FACTOR <br /> EQUIPMENT TAG NATIONAL FACILITIES SERVICES <br /> ONE NOMINAL VOLTAGE SYSTEM EXISTS.PROVIDE MEANS OF IDENTIFICATION AS <br /> e <br /> REQUIRED PER THIS ARTICLE. AS SWITCH RATING IN AMPERES LED LIGHT EMITTING DIODE POST OFFICE BOX 12916 <br /> AUTOMATIC TRANSFER SWITCH LONG TIME,SHORT TIME, OAKLAND,CA 94604 <br /> FIXTURE DESIGNATION E. CONTRACTOR SHALL VERIFY FINAL PLACEMENT AND CONNECTION REQUIREMENTS AT TRIP RATING IN AMPERES LSIG INSTANTANEOUS&GROUND FAULT <br /> LUMINAIRE TYPETI PRIOR TO ROUGHING IN EQUIPMENT UTILITIES. <br /> 45KVA AWG AMERICAN WIRE GAUGE LLF LIGHT LOSS FACTOR <br /> CIRCUIT NUMBER,SWITCH LEG(WHERE SHOWN).0 PANEL NAME TRANSFORMER F. FINAL ACCEPTANCE OF WORK IN PLACE SHALL BE SUBJECT TO APPROVAL BY <br /> �yylly�Y OWNER'S REPRESENTATIVE. INSTALLATION APPROVAL SHALL BE BASED ON AV AUDIO VISUAL LRC LIGHTING RELAY CABINET <br /> -0 2 CIRCUIT NUMBER(WHERE SHOWN) t APPROVED SUBMITTAL,SHOP DRAWINGS AND LOCAL INSPECTIONS. C CONDUIT MECH MECHANICAL <br /> NEW WORK �T TRANSFORMER G. CONTRACTOR SHALL SUBMIT RED-LINE RECORD DRAWINGS WITHIN TWO(2) CFOI CONTRACTOR FURNISHED MCB MAIN CIRCUIT BREAKER <br /> WORK WEEKS OF DATE OF NOTIFICATION OF FINAL APPROVAL. OWNER INSTALLED <br /> 7 EXISTING WORK TO REMAIN CL CENTERLINE MLO MAIN LUGS ONLY <br /> M TRANSFORMER H. ALL WORK SHOWN ON DRAWINGS IS IN PART SCHEMATIC,INTENDED TO CONVEY , <br /> f— �{ EXISTING WORK TO BE REMOVED I SCOPE OF WORK AND GENERAL LAYOUT. VERIFY ALL EXISTING CONDITIONS AND CEC CALIFORNIA ELECTRIC CODE MCA MINIMUM CIRCUIT AMPS <br /> MAKE ADJUSTMENTS AS REQUIRED. ELECTRICAL DRAWINGS ARE LARGELY <br /> GENERATOR DIAGRAMMATIC AND,THEREFORE,REPRESENT INSTALLATION INTENT AND CKT CIRCUIT MOCP MAXIMUM OVER CURRENT PROTECTION <br /> GUIDELINES;IT IS THE CONTRACTOR'S RESPONSIBILITY TO COVER ALL <br /> CONDUIT SYMBOLS ,o STATIONARY CIRCUIT BREAKER;RATING AS SHOWN ON PLANS CONDITIONS ON HIS PREPARED SHOP DRAWINGS. CLG CEILING (N) NEW <br /> I. CONTRACTOR SHALL PROVIDE UP-TO-DATE,ACCURATE,AND LEGIBLE CIRCUIT CR CRITICAL BRANCH N NEUTRAL <br /> CONDUIT INSTALLED CONCEALED ABOVE CEILINGS,IN WALLS IN FINISHED DIRECTORY WHICH APPLIES TO PANELBOARDS AND SWITCHBOARDS AS REQUIRED <br /> AREAS,OR EXPOSED IN UNFINISHED AREAS oho—® SWITCH AND FUSE;RATING AS SHOWN ON PLANS BY NEC ART.408.4 DIRECTORY SHALL BE LOCATED ON THE FACE OR ON THE CFL COMPACT FLUORESCENT NC NORMALLY CLOSED <br /> DOOR OF EACH PANELBOARD OR AT EACH SWITCH ON A SWITCHBOARD.WITHIN Hellmuth,Obata&Kassabaum,Inc. <br /> GROUND ROD IN GROUND WELL EACH PANELBOARD PRIOR TO FINAL ACCEPTANCE OF WORK IN PLACE. CL CONNECTED LOAD NEC NATIONAL ELECTRIC CODE <br /> -——- CONDUIT INSTALLED BELOW FINISHED FLOOR OR BELOW GRADE 1218 Third Avenue,Suite 1315 <br /> -0 (2) JUNCTION BOX J. LABEL ALL WIRING DEVICES WITH SOURCE PANELBOARD AND CIRCUIT NUMBER CCT CORRELATED COLOR TEMPERATURE NEMA NATIONAL ELECTRICAL Seattle,WA 98101 USA <br /> —0 CONDUIT TURNING UP ON COVER PLATE. SEE SPECIFICATIONS. MANUFACTURER'S ASSOCIATION t+1 206 493 1771 f+1 206 493 1778 <br /> 0 CONDUIT TURNING DOWN 206V/120V SURFACE MOUNTED PANELBOARD OR TERMINAL CABINET CRI COLOR RENDERING INDEX NIL NIGHT LIGHT <br /> K. LABEL ALL NEW PANELBOARDS,SWITCHBOARDS AND MOTOR CONTROL CENTERS <br /> 208V/120V FLUSH MOUNTED PANELBOARD OR TERMINAL CABINET WITH ENGRAVED LAMINATED-PLASTIC NAMEPLATES MOUNTED WITH An reprodeonon a lnto�lec[ual propenv rigors reserves <br /> I CONDUIT STUBBED OUT WITH BUSHING CORROSION-RESISTANT SCREWS. SEE SPECIFICATIONS. (D) DEMOLISH EXISTING NO NORMALLY OPEN eta <br /> In Association with <br /> � CONDUIT STUBBED OUT AND CAPPED 480V/277V SURFACE MOUNTED PANELBOARD OR TERMINAL CABINET L. ALL INTERIOR OUTLET,JUNCTION AND PULL BOXES SHALL BE METALLIC,SIZED OF DEMAND FACTOR NITS NOT TO SCALE <br /> 48OV/277V FLUSH MOUNTED PANELBOARD OR TERMINAL CABINET PER CODE FOR THE NUMBER OF CONDUCTORS THEREIN. DL DESIGN LOAD OFCI OWNER FURNISHED Mortenson <br /> FLEXIBLE CONDUIT WITH SINGLE POINT OF CONNECTION AT CONTRACTOR INSTALLED Geneal contractor <br /> ELECTRICAL EQUIPMENT M. ALL ELECTRICAL RACEWAYS SHALL BE CONCEALED IN THE WALLS AND ABOVE DC DIRECT CURRENT OC OVER CURRENT 10230 NE Points Drive,Suite 300 <br /> SUSPENDED CEILING UNLESS OTHERWISE NOTED. Kirkland,WA 98033 <br /> —c— GROUNDING CONDUCTOR WIRING DEVICE SYMBOLS N. ALL CONDUCTORS SHALL BE #12 AWG MINIMUM TYPE THHN/THWN UNLESS DPDT DOUBLE POLE,DOUBLE THROW PB PULL BOX <br /> OTHERWISE NOTED. DPST DOUBLE POLE SINGLE THROW 0,PH PHASE ConXtech,Inc <br /> CONDUIT HOMERUN;ROUTE TO PANELBOARD,CABINET,OR TERMINAL -0 120V,DUPLEX RECEPTACLE OUTLET Shudural Fabricator <br /> BOARD INDICATED,AND TERMINATE CONDUCTORS TO CIRCUIT OVER 0. ALL CEILING MOUNTED ELECTRICAL DEVICES SHALL BE SUPPORTED FROM THE DIST DISTRIBUTION PNL PANEL 6701 Koll Center Parkway,Suite 150 <br /> CURRENT PROTECTIVE DEVICE :9 120V,5MA GFCI TYPE DUPLEX RECEPTACLE OUTLET CEILING GRID,NOT FROM CEILING TILE.LIGHTING SHALL BE SUPPORTED FROM Pleasanton,CA 94566 <br /> STRUCTURE ABOVE. EQ EQUIPMENT BRANCH PVC POLYVINYL CHLORIDE CONDUIT <br /> 120V,DOUBLE DUPLEX RECEPTACLE OUTLET <br /> P. ELECTRICAL PLANS ARE MOSTLY DIAGRAMMATIC.CONTRACTOR SHALL PROVIDE KPFF Consulting Engineers <br /> PANEL DESIGNATIONS (E) EXISTING TO REMAIN PTS PNEUMATIC TUBE STATION Civil 9 actual Engineering <br /> 120V,SMA GFCI TYPE DOUBLE DUPLEX RECEPTACLE OUTLET CONNECTIONS BETWEEN FIXTURES AND LIGHTING CONTROL DEVICES SUCH AS <br /> OCCUPANCY SENSORS,LIGHT SWITCHES,AND LIGHTING CONTROL PANEL TO (ER) REMOVE EXISTING. P POLE 1601 Fifth Avenue,Suite 1600 <br /> PANEL DESIGNATION TAG PROVIDE AN OPERABLE LIGHTING SYSTEM. Seattle,WA 98101 <br /> I EHI WIRING DEVICE NOTES Q. IN THE EVENT OF ANY INCONSISTENCY BETWEEN ITEMS INDICATED ON THE (EL) RELOCATE EXISTING. PWR POWER <br /> PANEL NO. PLANS AND/OR THE SPECIFICATIONS,THE ONE WHICH PROVIDED THE MOST EC EMPTY CONDUIT (R) RELOCATE EXISTING MazzettiMEP i FP Engloeering <br /> H -4 / 7V THE FOLLOWING NOTATIONS MAY BE USED WITH ANY RECEPTACLE TYPE TO FURTHER COMPLETE WORK OR HIGHER STANDARD SHALL PREVAIL. 2013 4th Avenue,Suite 200 <br /> L-20808/12120V ELEC ELECTRICAL RCP REFLECTED CEILING PLAN <br /> DEFINE THE SYMBOL: R. SUPPLY AND INSTALL ALL REQUIRED SUPPORTS AND BRACING OF EQUIPMENT Seattle,WA 98121 <br /> E- EMERGENCY BRANCH C = CRITICAL BRANCH RECEPTACLE,PROVIDE RED DEVICE AND RED AND CONDUITS FOR PROPER EQUIPMENT INSTALLATIONS AND CODE COMPLIANCE. ELEV ELEVATOR RSC RIGID STEEL CONDUIT <br /> N - NORMAL POWER BRANCH COVER PLATE IF PLASTIC,SEE SPECIFICATIONS <br /> LE LEVEL NO. IG = ISOLATED GROUND RECEPTACLE S. ALL EXPOSED CONDUITS SHALL BE INSTALLED AT RIGHT ANGLE TO ROOM OR E,EMER EMERGENCY SPOT SINGLE POLE,DOUBLE THROW Key Plan <br /> L = LOCKING STRUCTURE. EXPOSED CONDUITS SHALL BE SUPPORTED FROM BUILDING <br /> DISTRIBUTION PANEL DESIGNATION TAG LS = LIFE SAFETY BRANCH RECEPTACLE,PROVIDE RED DEVICE AND RED STRUCTURE USING APPROVED PIPE HANGERS. EMT ELECTRO METALLIC TUBING SPST SINGLE POLE,SINGLE THROW <br /> 1DP1 COVER PLATE IF PLASTIC,SEE SPECIFICATIONS <br /> PANEL No. M = FOR MONITORING EQUIPMENT,COORDINATE MOUNTING HEIGHT WITH T. ALL CONDUITS SHALL BE SIZED AS PER NEC UNLESS LARGER SIZES ARE NOTED EWC ELECTRIC WATER COOLER SWBD SWITCHBOARD <br /> � <br /> Q = EQUIPMENT EQUIPMENT SYSTEM RECEPTACLE,PROVIDE SPECIAL DP- DISTRIBUTION PANEL - ON THE DRAWINGS. <br /> LABEL,SEE SPECIFICATIONS EWH ELECTRIC WATER HEATER SWGR SWITCH GEAR N <br /> LEVEL NO. T TAMPER RESISTANT RECEPTACLE U. ALL CUTTING,PATCHING A PAINTING REQUIRED FOR THE CONCEALED <br /> TV = FOR TELEVISION,COORDINATE MOUNTING HEIGHT WITH TELEVISION INSTALLATION OF CONDUITS SHALL BE PROVIDED BY THE CONTRACTOR.DO NOT EMS EMERGENCY MANAGEMENT SYSTEM SYS SYSTEM S <br /> WP = WEATHERPROOF,CORD CAN BE PLUGGED IN WITH COVER CLOSED CUT OR DRILL STRUCTURAL MEMBERS WITHOUT WRITTEN APPROVAL FROM <br /> STRUCTURAL ENGINEER.ALL CUTTING AND PATCHING SHALL BE NEAT,AND FA FIRE ALARM TP TAMPER RESISTANT <br /> PATCHING SHALL MATCH ADJACENT SURFACE AS TO TEXTURE AND FINISH. �y <br /> LIGHTING SYMBOLS FAAP FIRE ALARM ANNUNCIATOR PANEL TB,TTB TERMINAL BACKBOARD . <br /> V. ALL PENETRATIONS THROUGH FIRE RATED WALLS,FLOORS OR CEILINGS SHALL ' <br /> BE SEALED IN ACCORDANCE WITH A UL APPROVED SYSTEM THAT MAINTAINS THE FACP FIRE ALARM CONTROL PANEL TC TERMINAL CABINET <br /> SURFACE STRIP INTEGRITY OF THE EXISTING FIRE RATING.PROVIDE AN ENCLOSURE OF EQUAL <br /> FIRE RESISTANT RATING AROUND ALL FIXTURES AND EQUIPMENT INSTALLED IN FATC FIRE ALARM TERMINAL CABINET TEL TELEPHONE <br /> OR PENETRATING FIRE RATED SEPARATIONS. <br /> FARA FIRE ALARM REMOTE ANNUNCIATOR TP TAMPER PROOF Professional Seals <br /> LIGHTING CONTROL SYMBOLS FCIP FIRE ALARM <br /> ARMINGPANEL CCOONTROL& TVSS SURGE VOLTAGE <br /> OR <br /> S SINGLE POLE SWITCH FPRP FIRE ALARM PUMP STATUS PANEL V VOLT 1G C.S <br /> FIRE ALARM VOICE <br /> VCS VD VOLTAGE DROP <br /> COMMUNICATION PANEL Q/ e <br /> o .. <br /> FSD FIRE SMOKE DAMPER VFD VARIABLE FREQUENCY DRIVE / <br /> LIGHTING CONTROL NOTES FVNR FULL-VOLTAGE,NON-REVERSING VA VOLT AMPERES 4090 <br /> fi II v <br /> FVR FULL-VOLTAGE,REVERSING W WATT ONAL 1+�G�rAg`a <br /> THE FOLLOWING NOTATIONS MAY BE USED WITH MOST SWITCH TYPES TO FURTHER iI <br /> DEFINE THE SYMBOL: FLA FULL LOAD AMPS(NAME PLATE) W WIRE <br /> = A LINE THROUGH THE SWITCH SYMBOL MEANS THE DEVICE SHALL BE RED No. Description Data <br /> WITH A RED COVER PLATE IF PLASTIC PLATES ARE USED FLC FULL LOAD CURRENT(NEC) WP WEATHERPROOF PERMIT SET 03/18/20 <br /> WP = WEATHERPROOF DEVICE AND COVER <br /> (F) FUTURE XFMR TRANSFORMER <br /> XP EXPLOSION PROOF <br /> DRAWING INDEX <br /> E1.1 ELECTRICAL SYMBOL LEGEND AND DRAWING INDEX <br /> E2.1 SITE PLAN - ELECTRICAL <br /> E3.1 LEVEL P2 FLOOR PLAN - NORTH AREA-ELECTRICAL <br /> E3.2 LEVEL P2 FLOOR PLAN - SOUTH AREA- ELECTRICAL <br /> E4.1 ENLARGED PARTIAL FLOOR PLANS - ELECTRICAL <br /> E5.1 EXISTING ONE-LINE DIAGRAM <br /> E5.2 DETAILS AND SCHEDULES <br /> KIP Project No: CAP020407 <br /> HOK Project No: <br /> Sheet Title: <br /> ELECTRICAL <br /> SYMBOLS AND <br /> DRAWING INDEX <br /> O,,,3,na1,e 36 x�4. <br /> Sheet Number <br /> E1 . 1 <br />