My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2930 MAPLE ST 2 KAISER PERMANENTE 2025-01-27
>
Address Records
>
MAPLE ST
>
2930
>
KAISER PERMANENTE
>
2930 MAPLE ST 2 KAISER PERMANENTE 2025-01-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/27/2025 8:20:12 AM
Creation date
12/31/2024 1:30:27 PM
Metadata
Fields
Template:
Address Document
Street Name
MAPLE ST
Street Number
2930
Unit
2
Tenant Name
KAISER PERMANENTE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
224
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> KAER <br /> PER ANENTE <br /> Project <br /> Kaiser Permanente Everett <br /> MOB Backfill <br /> 2929 PINE STREET <br /> EVERETT,WA 98201 <br /> Prepared for <br /> KAISER FOUNDATION <br /> FAN START/STOP HEALTH PLAN, INC. <br /> AND FAN STATUS NATIONAL FACILITIES SERVICES <br /> ,"",,�'7 <br /> SUPPLY AIR POST OFFICE BOX 12916 <br /> cS TEMPERATURE OAKLAND,CA 94604 <br /> FS MOD SENSOR <br /> FAN CR <br /> TS <br /> FLOW <br /> SENSOR <br /> SA SA <br /> PRIMARYAIR ELECTRIC <br /> DAMPER HEATING COIL , <br /> FILTER <br /> FAN POWERED <br /> SPACE AIRTERMINAL <br /> TEMPERATURE <br /> SENSOR <br /> Hellmuth,Obata&Kassabaum,Inc. <br /> T 1218 Third Avenue,Suite 1315 <br /> Seattle,WA 98101 USA <br /> t+1 206 493 1771 f+1 206 493 1778 <br /> TYPICAL FAN POWERED AIR TERMINAL:(FTU) 202o rotluG1on 6 l°I"`°al°°°°T riahla rasa as <br /> VAV FAN POWERED AIR TERMINAL In Association with <br /> Bi M701 NOT TO SCALE Mortensen <br /> General Contractor <br /> 10230 NE Points Drive,Suite 300 <br /> Kirkland,WA 98033 <br /> MaZZettl <br /> MEP+FP Englneedng <br /> 2013 4th Avenue,Suite 200 <br /> Seattle,WA 98121 <br /> SEQUENCE OF OPERATIONS <br /> TYPICAL FAN POWERED AIR TERMINAL'. <br /> WARM-UP MODE: <br /> 1. TEMPERATURE CONTROLS SHALL BE ACTIVATED TO ESTABLISH OCCUPIED SPACE Key Plan <br /> TEMPERATURE SET POINT, <br /> OCCUPIED MODE: <br /> 2. FAN POWERED AIRTERMINAL SHALL BE ENABLED AND RUN CONTINUOUSLY DURING <br /> OCCUPIED MODE. <br /> 3. FAN POWERED AIRTERMINAL AIRFLOW SENSOR SHALL MODULATE PRIMARYAIR <br /> DAMPERTO MAINTAIN SPACE TEMPERATURE SET POINT. <br /> 4. ON CALL FOR COOLING:PRIMARY AIR DAMPER SHALL BE MODULATED TO MAXIMUM <br /> DESIGN AIRFLOW. <br /> 5. ON CALL FOR HEATING:PRIMARY AIR DAMPER SHALL BE MODULATED TO MINIMUM <br /> DESIGN AIRFLOW AND ELECTRIC HEAT SHALL BE MODULATED TO MAINTAIN ROOM <br /> TEMPERATURE SET POINT. <br /> UNOCCUPIED MODE: <br /> Professional Seals <br /> 6. FAN POWERED AIR TERMINAL SHALL BE DISABLED. <br /> 7. ON DROP IN SPACE TEMEPRATURE BELOW 55 DEG F,FAN POWERED AIR TERMINAL <br /> CONTROLS SHALL BE ACTIVATED TO OPERATE UNDER HEATING MODE. 'S�•4'OF <br /> 8. FAN POWERED AIR TERMINAL SHALL CONTINUE TO OPERATE UNTIL SPACE <br /> TEMPERATURE EXCEEDS 60 DEG F. % z <br /> 24672 <br /> TONAL <br /> No. Description Data <br /> MOB BACK FILL ISSUED FOR PERMIT 2022/10/14 <br /> KIP Project No: CAP022248 <br /> HOK Project No: 20.05003.00 <br /> Sheet Title: <br /> MECHANICAL <br /> CONTROLS <br /> —ginel is 30 x 42 D. [s&this drawing. <br /> Sheet Number <br /> B1 M701 <br />
The URL can be used to link to this page
Your browser does not support the video tag.