Laserfiche WebLink
Permit#: M2312-097 <br /> Site Address: 2525 W Casino Rd engineered <br /> EVERETT RTU Owner: Washington Capital MGMT I I systems <br /> Application Date: 12/28/2023 <br /> Description: RTU Replacement <br /> Review Status: Approved by Building,C.Bearman 5300 DENVER AVENUE SOUTH <br /> Review Date: 1/18/2024 SEATTLE,WASHINGTON 98108 <br /> UNIT REPLACEMENT (2 787.65°° <br /> L City of Everett Permit Review THE PLANS AND SPECIFICATIONS HEREIN <br /> EVERETT Status:Reviewed for Permit ARE OWNED BYAND FOR THE SOLE USE OF <br /> 01/18/2024 12:07:51 PM ACCO ENGINEERED SYSTEMS,INC.(-ACCO'), <br /> AND MAYNOT BE REPRODUCED OR USED <br /> BY OTHERS FOR ANY PURPOSE UNLESS <br /> AUTHORIZED BYACCO IN WRITING.ACCO <br /> SYMBOL LEGEND D RAW I N G INDEX CANNTION IN HE EVENT OF UN WARRANTY,OR <br /> OBLIGATION/N THE EVENT OF UNAUTHORIZED USE. <br /> HVAC PIPING <br /> SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION w <br /> O AREA OF WORK <br /> (N)® �(E) NEW(rv)a EXISTING(E)RECTANGULAR SUPPLY AIR DUCT RISER ® ® SUPPLY AIR GRILLE EUMAnc zw-cv FLEXCONNECTOR <br /> DRAWING INDEX KEY: 0 w <br /> (N) <br /> m() NEW RECTANGULAR OUTSIDE AIR DUCT RISER URN AIR GRILLE PNEUMATIC Swcv N RUBBER SPHERICAL CONNECTOR N E 4� m NOT INCLUDED WITH ISSUE C) y <br /> (N)� Z(E) Ew(N)AEXISTING(El RECTANGULAR RETURN AIR DUCT RISER ® ® nnuST GRILLE 'MI EUMATICBUTrENFLYzw CV QQQ IPLEGROOVEDCOUPLINGS 0 NEWHA REVISED LU <br /> X IMI O NO CHANGES w <br /> KEY PLAN <br /> (N)® �(E) NEW(N)a EXISTING(E)RECTANGULAR EXHAUST AIR DUCT RISER RGDNDDIFFUSER _I+I_ EUMATICBUTTERFLYSW<V(DIVERTING) E ENDCAP SHEET <br /> DRAWING TITLE cn <br /> (N) ( I (E) NEWIN)a EXISTING(E)ROUND AIR DUCT RISER gUNEAR DIFFUSER t It PNEUMATIC BUTTERFLY SW-CVNIXING) INDFLANGE NO. A <br /> M0.00 COVERSHEET p�9� sH"fr <br /> NEW SINGLE LINsa DOUBLE LINE RECTANGULAR OR Rourvo OucT SIDE WALL GRILLE � TORrzsozwcv CONCENTRIC REDUCER M0.01 CONSTRUCTION REQUIREMENTS � <br /> EXISTING SINGLE LINE a DOUBLE LINE RECTANGULAR OR ROUND DUCT WALLLOUVER TORIZED awcV L) ECCENTRIC REDUCER M0.02 PERMIT REQUIREMENTS i1 <br /> 0 <br /> M1.R1 EQUIPMENT SCHEDULES,ROOF DEMO&HVAC PLANS � FgEcrsresE�t� <br /> �X X DUUCNdORKTTOBEDEMOL55HE�(IOPTION) f��1 ALL(WITH EXTRACTOR A WITHOUT EXTRACTOR) TOR-DBUTTERFLY2W-CV I UNION <br /> rX—X—X� IsnrvODouBLE LINED (W OPTION 0 0 SPINAL smEw M5.01 MECHANICAL DETAILS <br /> (HATCH OPTION) \ <br /> ��///� TT?T. IBTING DUCTWORK TO BE DEMOLISHED \�'111('('ll ltl.\ EXIBLE DUCT TORIZED BUTTERFLY-CV(DIVERTING) � HRPDER VALVE EXPIRES:11-28-2024 <br /> 44"G® DUCT WITH WRAP,DIMENSIONS SHOWN ARE LD.OFDUCT SECTION NUMBER SECTION DEFAULT WRAP THIC.E..�I.E.UNLESS OTHERWISE NOTED ON PLANS MBOL SHEET NUMBER CALL OUT tMm« TORIZED BUTTERFLY 3W OW ARROW <br /> cv(MIXING) <br /> Y� DUCT WITH LINING.DIMENSIONS SHOWN ARE I.D.OF DUCT 2 42.12 3 nICRI�M'SEUR RGTYPE 8s¢E TE VALVE EssUREGnucEWITHSHUTOFFVALVE <br /> DEFAULT LINING THICKNESS=1-L.UNLESS OTHERWISE NOTED ON PLANS 1 14 'i 4 }W!(CFM ttP.M ICI <br /> L JIM SINGLE DOUBLE LINE DUCTWORK WITH TRANSITIONAL FITTING #Q EQUIPMENT LABEL TAG > RAILILVA-E TEMPERATURE SENSOR B THERMOWELL <br /> 1 <br /> DARE ry BLE LINE SQUARE TO ROUND TRANBITIDN FTING ® CEILINGORDU-ACDEBB PANEL BYOFNERALGDNTRACTOR 11 VALVE WITH MEMQRYSTOP THERMQMETER <br /> o0+ 05] oW-DIUS ELBOW oSY SQUARE ELBOW WITH TURNINGVANES FLOW ARROW a FLOW ARROWCURVED GLOBE VALVE T TES PLUG <br /> (D ® 0 ROUND DUCT TURNING VERTICAL q)RECT.DUCT TURNING VERTICAL IG ION CLOUD � BUTTERFLYVALVE Fsp OW SWITCH <br /> SINGLE LANE MANUAL IN ANTALvoLUME OAMPER PEGQ CGO <br /> ON�RAciAORLINE WITH TRAPTO APPROVED RECEPTOR BY PLUMBING CHECK VALVE �\U IPLEDUtt VALVE <br /> pp� TDRCEDDAMPER(ELECTNIG, 0 CONTRACTOR TRAPTDAPPRDEDREQEPQRBYPLDMBING RAWER RELIEF VALVE <br /> pP-Ef3- ©� MOTORIZED DAMPER(PNEUMATID) GASSTUB-UP BY PLUMBING CONTRACTOR STRAINERWIT HBLDWDOMAVALVE AT WAX VALVE <br /> FIRE DAMPER(SINGLE LINE AND DOUBLE LINE) COLD WATER STUBUP BY PLUMBING CONTRACTOR ^y SKETSTAMNER VACUUM BREAKER <br /> ❑1�1 ❑ TO <br /> F E/SMOKE DAMPER(SINGLE LINE AND DOUBLE LINE) ifH cnnoN BV ELECTRICAL CONTRACTOR SUCTION DIFFUSER �T STEAM TRAP <br /> SMOKE DETECTOR(DOGTTYPE) A. G DELTA t R°ENT MANUAL ANGLEVA-E SCOPE OF WORK APPLICABLE CODES <br /> Anc PRESSURE SENSOR & POINTOFCOINNECTION RVENT-AUTO ® HT GLAss <br /> 1. REMOVE AND REPLACE ROOFTOP PACKAGE UNIT WITH <br /> sD SMOKE DETECTOR(AREA TYPE) ® NEGULATOR PRESSUREREDUCING VALVE 0 TERDRIER LIKE EQUIPMENT. WASHINGTON MECHANICAL PROJECTS: <br /> y IIC�II <br /> OT THERMOSTAT WITH ZONE NUMBER PRESSURE B.—WING VALVE EOLENOm VALVE ALL WORK SHALL BE IN FULL ACCORDANCE WITH APPLICABLE <br /> I�GI LOCAL,STATE,AND FEDERAL CODES,LAWS AND REGULATIONS. 1 12/13/2023 ISSUE FOR REVIEW TD <br /> ALL WORK AND MATERIALS SHALL BE IN FULL ACCORDANCE WITH, <br /> CO2 zservsoR L TO Flow CONTROL ® WITH SENSING Bulb BUTIN TLIMITEDTO: No. Date Description By <br /> © 2sENsoR CIRCUIT.ETTIEF PRESSURE <br /> wUGE STEAM • 2018 INTERNATIONAL BUILDING CODE WITH WA AMENDMENTS Revisions <br /> O <br /> • 2020 NATIONAL ELECTRICAL CODE WITH WA AMENDMENTS <br /> ''''��r�"""" • 201:INTERNATIONAL MECHANICAL CODE WITH WA AMENDMENTS PFO)eCt <br /> CO SOR SEN ,Iy<I BALL VALVE WITH HOSE CONNECTION SOR DIFFERENTIAL PRESSURE SEN • 2018 UNIFORM PLUMBING CODE WITH WA AMENDMENTS <br /> - • 2018 WASHINGTON STATE ENERGY CODE <br /> OCCUPANCY SENSOR FLOW METER INLME HOSE BIBS <br /> • 2018 INTERNATIONAL FIRE CODE WITH WAAMENDMENTS EVERETT RTU <br /> QG FM � <br /> FM UNIT REPLACEMENT <br /> ® LL SWITCH OW METER TURBINE <br /> ALL WORK SHALL BE IN ACCORDANCE WITH THE FOLLOWING <br /> ABBREVIATIONSADDITIONAL GUIDELINES WHERE REQUIRED BY CODE: 2525 CASINO RD <br /> • SHEET METAL AND AIR CONDITIONING CONTRACTORS EVERETT,WA.98204 <br /> AFF ABOVE FINISHED FLOOR (D) DEMO HT HEIGHT OD OUTSIDE DIMENSION TSTAT THERMOSTAT NATIONAL ASSOCIATION(SMACNA) <br /> AHJ AUTHORnY HAVING JURISDICTION CIA DIAMETER HHWR HEATING HOT WATER RETURN OFI OPENING TU TOP UP • AMERICAN SOCIETY OF HEATING,REFRIGERATION AND <br /> AP ACCESS PANEL DSD DUCT SMOKE DETECTOR HHWS HEATING HOT WATER SUPPLY OSA OUTSIDE AIR TYP TYPICAL AIR-CONDITIONING ENGINEERS(ASHRAE) <br /> ISO <br /> AREA SMOKE DETECTOR DWG DRAWING HPG HIGH PRESSURE GAS PLBG PLUMBING UBC UNIFORM BUILDING CODE • AMERICAN SOCIETY OF MECHANICAL ENGINEERS(ASME) <br /> BDD BACKDRAFT DAMPER (E) EXISTING TIPS HIGH PRESSURE STEAM POC POINT OF CONNECTION UC UNDERCUT • AMERICAN SOCIETY OF CIVIL ENGINEERS(ASCE) Title <br /> BF BOTTOM FLAT EA EXHAUST AIR HVLS HIGH VELOCITY LOW SPEED FAN RECIP RECIPROCATING UG UNDERGROUND • NATIONAL FIRE PROTECTION AGENCY(NFPA) <br /> BOD BOTTOM OF DUCT EG EXHAUST AIR GRILLE ID INSIDE DIMENSION (R) RELOCATE UMC UNIFORM MECHANICAL CODE VICINITY MAP • OCCUPATIONAL SAFETY AND HEALTH ACT(OSHA) COVER SHEET <br /> BOI BOTTOM OF INSULATION ELB ELBOW INS INSULATION RA RETURN AIR UNO UNLESS NOTED OTHERWISE <br /> BOP BOTTOM OF PIPE ELEC ELECTRICAL INT INTERIOR REQ'D REQUIRED UTR UP THROUGH ROOF <br /> CA COMPRESSEDAIR EO EQUIPMENT (L) LINED REV REVISION V VENT - <br /> CD CONDENSATE EXH EXHAUST LR LINEAR RETURN RG RETURN OR TRANSFER GRILLE VAV VARIABLE AIR VOLUME --- -- ___ <br /> CE CEILING EXHAUST EXT EXTERIOR LS LINEAR SUPPLY RG REFRIGERANT GAS VFD VARIABLE SPEED DRIVE <br /> CENTR CENTRIFUGAL (F) FUTURE MA MIXED AIR RGHP REFRIGERANTGA4-HIGH PRESSURE VIF VERIFY IN FIELD <br /> CFF CAP FOR FUTURE FD FIRE DAMPER MECH MECHANICAL RH REHEAT VOL VOLUME � • <br /> CFM CUBIC FEET PER MINUTE FLEX FLEXIBLE MPG MEDIUM PRESSURE GAS RL REFRIGERANT LIQUID WMS WIRE MESH SCREEN <br /> CHWR CHILLED WATER RETURN FLR FLOOR MFR MANUFACTURER RMF RAPID MOUNT FRAME XFER TRANSFER PROPERTY INFORMATION T.DALGLEISH T.TOUTONGHI <br /> CHWS CHILLED WATER SUPPLY FLU FLUE MD MOTORIZED DAMPER RNA ROUND NECK ADAPTER <br /> CL CENTERLINE FIR FLOOR RETURN MTD MOUNTED RND ROUND Designed By Checked By <br /> CLG CEILING FS FLOOR SUPPLY MTL METAL RR REFRIGERANT RELIEF - PARCEL#:28041400201700 T.DALGLEISH T.MATSUSHIMA <br /> CMU CONCRETE MASONRY UNIT FSD FIRE SMOKE DAMPER MUA MAKE UP AIR IRS REFRIGERANT SUCTION <br /> CO COOLING ONLY GA GAUGE MVD MANUAL VOLUME DAMPER SA SUPPLY AIR <br /> CA COMBUSTION AIR GALV GALVANIZED NG NATURAL GAS SG SUPPLY GRILLE LEGAL DESCRIPTION:SEC 14 TWP 28 RGE 04 1-RT-6A)W 200 Drawn By Project Manager <br /> CONC CONCRETE GC GENERAL CONTRACTOR (N) NEW SM SHEET METAL FT OF E 863.13 FT OF N 665.04 FT OF NW1/4 NW1/4 LESS CO 2873742 AS SHOWN <br /> COND CONDENSATE GEXH GREASE EXHAUST N/A NOT APPLICABLE SS STAINLESS STEEL - RD LESSST HWY TGW W 20OFT OF E 663.13FT OF N 665.04 FT <br /> CONN CONNECTION GPH GALLONS PER HOUR INC NORMALLY CLOSED STD STANDARD •• OF NW1/4 NW1A LESS N 30 FTLESS S/HY TGW W 100 FTOF Job Number Scale <br /> CONT'R CONTRACTOR GPM GALLONS PER MINUTE NIC NOT IN CONTRACT TA TRANSFER AIR E463.13 FT OF N 665.04FT OF NW1/4 NW1/4 LESS N 30FT FOR <br /> CR CEILING RETURN GR GLYCOL RETURN NO NORMALLY OPEN TD TOP DOWN CO RD LESS ST HWY M O O O <br /> CS CEILING SUPPLY GS GLYCOL SUPPLY NTS NOT TO SCALE TF TOP FLAT <br /> CWR CONDENSER WATER RETURN GYP GYPSUM BOARD OBD OPPOSED BLADE DAMPER TOD TOP OF DUCT <br /> CWS CONDENSER WATER SUPPLY HOA HAND-OFF-AUTO OC ON CENTER TOP I TOP OF PIPE <br />