Laserfiche WebLink
6/26/23,3:37 PM waenergycodes.com/print_project_summary_form.php?k=Y29tYm9fdGZ2X3B0PW11Y19odmFjX3N5c196b25pbmdfc21uZ2xIJTdDcGRfaWSpdGIhbF90ZW5hbnQmdGZ2PW11Y19od... <br /> MECHANICAL COMPLIANCE SUMMAR '' " <br /> III <br /> 2018 WSEC Compliance Forms for Commercial Buildings including Group R2,R3&R4 over 3 stories and all RI • ! roistered ll;y:©202 q,;Al ig tgreseryddNy <br /> Project Title Waterline Gym TI-2018 WSEC For Buil; 'aepartn i se 'Date: Jun 26,2023 . <br /> 2900 Grand Avenue ju 3 0 2023 I <br /> Project Address Spaces 4&5 2 2023 <br /> Project&Applicant Everett,WA 98201 NOV'�iU 1 J <br /> Information CITY OF EVERETT <br /> Applicant Name Yumi Roth <br /> Applicant Phone _ 360-863-6677 Permit Services r��7 -, <br /> Applicant Email nfo(c�lrenschen_ineering.com CI " O EVERET <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com Pei I I11 i Services <br /> General Occupancy All Commercial General Building Use Entmt/Assembly,Fitness/Health Club Building Cond.Floor 7 195 <br /> Type Area <br /> New Building Project Cond.Floor Area 7,195 <br /> Alteration <br /> Tenant Spaces—First Build or Addition Single Zone Systems& Floors Above Grade 1 <br /> General Project Types Out Mechanical Mechanical Equipment Compliance Method I - <br /> Scope Scope Compliance Method P General <br /> Mechanical Project Description ERV/DOAS installed for all ventilation.Split System ductless heat pump installed for spaces <br /> Economizer Equipment Efficiency <br /> DOAS Ventilation Higher Equipment <br /> Project Type Mechanical Scope Exception(s) Compliance <br /> Mechanical Compliance Provided? Efficiency Option Applied? <br /> Applied? Verification <br /> Scope and Method • - <br /> Tenant Spaces—First Single Zone Systems& Yes Yes NA COMPLIES <br /> Build Out Equipment <br /> Additional Efficiency <br /> Higher equipment efficiency and fan FEG <br /> Credits Includedluded(AEC) <br /> Does building include occupancy classifications <br /> requiring DOAS? Yes Does project include DOAS equipment? Yes <br /> Based on project scope do TSPR requirements apply? �„ Do all systems comply with Appendix D standard reference design or qualify for an No <br /> exception to TSPR? I <br /> Scope&Space Conditioning TENANT SPACES—FIRST BUILD OUT-SINGLE ZONE SYSTEMS&EQUIPMENT Compliance Verification COMPLIES <br /> Single Zone Air Systems Category-Heat pump,unitary,thru-wall,SDHV <br /> Air Systems Summary Information <br /> Quantity Supply Airflow Ventilation CFM Ventilation Energy Recovery <br /> System/Equip ID of Items Control Ventilation Standard (Total if Multiple Items) Air Source Paired with DOAS Ventilation energy recovery Efficiency(%) <br /> HP-lot Staged volume ASHRAE Standard 62.1 _ 700 Separate DOAS DOAS-101 _ Yes per C403.7.6 Energy Recovery 66 <br /> HP-102 Variable air volume ASHRAE Standard 62.1 700 Separate DOAS DOAS-102 Yes per C403.7.6 Energy Recovery 66 <br /> HP-103 Staged volume ASHRAE Standard 62.1 100 Separate DOAS DOAS-101 Yes per C403.7.6 Energy Recovery 66 <br /> Air Systems&Equipment-Cooling <br /> System/ Cooling System/Equip Type Specific Type Cooling Capacity AEC Efficiency Econo Exception Combined Efficiency Proposed Cooling CE Proposed Part PL Efficiency Compliance <br /> Equip ID per item(Btu/h) Multiplier Multiplier(FL&PL) Multiplier(AEC&Econo) Efficiency Units Load Efficiency Units Verification <br /> HP-101 Heat pump,air cooled Split system 112,000 I 1.0 1 _ 11.0 EER 13.8 IEER COMPLIES <br /> HP-102 Heat pump,air cooled Split system 112,000 1 1.0 1 _ 11.0 EER 13.8 IEER COMPLIES <br /> HP-I03 Heat pump,air cooled Split system 36.000 1 1.0 1 17.5 SEER IEER COMPLIES <br /> Air Systems&Equipment-Heating <br /> System HeatingSystem/Equip Type Specific Type Heat PumpHeatingCapacity(Btu/h) CoolingCapacity(Btu/h AEC Efficiency Proposed Heat Pump HPH Proposed Low OSA LTH Efficiency Compliance <br /> /Equip ID ' q PP p p ) Multiplier Heating Efficiency Units Temp Efficiency Units Verification <br /> HP-I 01 Heat pump,air cooled,heating Split system 106,000 112,000 1 3.4 COP 2.4 COP COMPLIES <br /> https://waenergycodes.com/print_project_summary_form.php?k=Y29tYm9fdGZ2X3B0PW 1 IY 19odm FjX3N5c196b25pbmdfc21uZ2xIJTd DcG Rfa W SpdGIhbF90ZW ShbnQmdGZ2P W 1 IY19odmFjX3N 5c196... 1/2 <br />