My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1701 121ST ST SE 2024 Plans 2025-02-03
>
Address Records
>
121ST ST SE
>
1701
>
Plans
>
1701 121ST ST SE 2024 Plans 2025-02-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/3/2025 11:06:42 AM
Creation date
1/24/2025 7:15:20 AM
Metadata
Fields
Template:
Address Document
Street Name
121ST ST SE
Street Number
1701
Permit
B2404-010
Year
2024
Notes
REMODEL EXISTING 4510SF, DEMO ENTRY CANOPY, NEW EXT DECKING
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TYPICAL ACCESSIBLE MOUNTING HEIGHTS OPERABLE PARTS LOCATION <br /> CI / 00 <br /> L1J <br /> o BACKSPLASH <br /> N <br /> LL'E° ---0 <br /> 0 <br /> BACKSPLASH BYD. w Z J Z O 0 m <br /> O lL Z O Q w ni <br /> WRAP PIPES WITH ¢ J I-0 Q¢ Q 3 4 co <br /> INSULATING w D U W a U J o <br /> MATERIAL 0° p N`I �r <br /> p -1 in <br /> FINISH END PANEL BYD. °? � LL: a <br /> U <br /> v � <br /> PIVOT AND TURNTABLE v M c9 9 d <br /> in SLIDE DOOR SYSTEM (D mZ d• CM 0 CL RK I WNEE <br /> ATTACH KICK TO FINISHEDLO 4FINISHED FLOOR FINISHED FLOOR O FINISHED FLOOR <br /> CABINET DOOR FLOOR STAIRS RAMPS <br /> 2,_O, FORWARD REACH UNOBSTRUCTED OBSTRUCTED HIGH OBSTRUCTED HIGH <br /> LIGHT <br /> 5"MAX FORWARD REACH 4"MAX SIDE REACH <br /> O I <br /> 1A KITCHEN SINK 1B SWITCH 1C ELEC. HANDRAIL ALLOWABLE CHANGES IN FL <br /> OUTLET 1D HEIGHT 2 FLOOR LEVELS Cf) <br /> TYPICAL PUBLIC RESTROOM MOUNTING HEIGHTS FLOOR LEVEL DETAILS w w LU <br /> (NOTE:INTERIOR SCOPE OF WORK INCLUDES UPDATING FINISHES ONLY AT EXISTING PUBLIC RESTROOMS.GREATER ACCESSIBILITY IS NOT 0 F- <br /> REQUIRED.PROPOSED ALTERATIONS WILL NOT REDUCE THE CURRENT LEVEL OF ACCESSIBLITY.MOUNTING HEIGHTS SHOWN FOR REFERENCE) I j Q <br /> 12" 54„MIN. Q Lu LU <br /> 36"MIN. M 42"MIN. - 1-- I_ <br /> Q L1J /A <br /> 2 24"MIN. 3 "-41" m = F- LU <br /> MM LU <br /> Z FLUSH /j U O - W <br /> GRAB BAR a0 g �CONTROL 2 = <br /> C-7 LL 2 Go O <br /> TOILET FLUSH LL y ro a 1 a C 1 LU J ~ <br /> _J�_j� O o <br /> CONTROL ON THE OPEN SIDE E3E3 � � � � o � � <br /> t <br /> <44A.F.F. rb'i N INSULATE PIPES—f _°� c J v v _ <br /> �1�x UNDER SINK. N a LL 14A C v C¢ U <br /> 1 18'„MAX ¢� ¢� <br /> SURFACE FINISHED <br /> 18 MIN FLOOR <br /> TOILET SANITARY MOUNTED PAPER TOWEL <br /> 3C FLOOR MOUNTED TOILET 3D PAPER 3E URINAL 3F NAPKIN 3G TOILET SEAT 3K LAVATORY 3L DSIPP 3M DISP./WASTE 3N COUNTERTOP O4 ALLOWABLE CHANGES IN FLOOR LEVELS <br /> HOLDER DISPOSAL COVER RECEPTACLE <br /> DISPENSER <br /> TYPICAL ACCESSIBLE APPLIANCE REQUIREMENTS ACCESSIBLE SIGNAGE REQUIREMENTS <br /> (NOTE:NOT ALL APPLIANCES SHOWN ARE INCLUDED IN THE INTERIOR SCOPE OF WORK) 703.1-GENERAL:TACTILE SIGNS SHALL CONTAIN BOTH RAISED CHARACTERS AND BRAILLE. <br /> 703.1.1-DESIGNATIONS:INTERIOR AND EXTERIOR SIGNS IDENTIFYING PERMANENT ROOMS AND SPACES SHALL COMPLY WITH SECTIONS 703.1,703.2,AND 703.3. <br /> Al 703.1.2-DIRECTIONAL AND INFORMATIONAL SIGNS:SIGNS THAT PROVIDE DIRECTION TO OR INFORMATION ABOUT INTERIOR SPACES AND FACILITIES OF THE SITE eRii <br /> SHALL COMPLY WITH SECTION 703.2. REGISTERED <br /> PROVID 3O" S2" 0 ARCHITECT <br /> AT LEAST 50/o OF <br /> CLEAR FL FREEZER REFRIGERATOR 703.3.11 LOCATE SIGNS ON LATCH SIDE OF DOOR WHEREVER POSSIBLE.AT DOUBLE DOORS,LOCATE TO THE RIGHT OF THE RIGHT-HAND DOOR OR ON THE NEARESTuj " �"'�- <br /> SPACE ADJACENT TO COMPARTMENT CL PROVIDE A 30" 52" ADJACENT WALL.EXCEPTION:SIGNS MAY BE LOCATED ON THE PUSH SIDE OF DOORS PROVIDED WITH CLOSERS AND WITHOUT HOLD OPEN DEVICES. <br /> THE DISHWASHER SHELVES,INCLUDING CLEAR FLO STATE OFC WASWZTON <br /> DOOR. THE THE BOTTOM OF THE SPACE POSITIONED 703.3.10 SIGNS SHALL BE LOCATED 48"MIN.FROM BASE OF LOWEST CHARACTER TO FLOOR LEVEL.60"MAX.TO THE BASE OF THE HIGHEST CHARACTER FROM THE <br /> DISHWASHER DOOR IN FREEZER,SHALL BE 54" FOR A PARALLEL FLOOR. <br /> THE OPEN POSITION MAXIMUM ABOVE THE APPROACH.THE N <br /> SHALL NOT FLOOR WHEN THE o CENTERLINE OF p ICC A117.1 1011.3-TACTILE EXIT SIGNS: DATE: 12/14/23 <br /> OBSTRUCT THE CLEAR SHELVES ARE � THE CLEAR FLOOR m SIGNAGE STATING"EXIT"SHALL BE PROVIDED ADJACENT TO EACH DOOR TO AN EXIT STAIRWAY,AN EXIT RAMP AN EXIT PASSAGEWAY OR AN EXIT DISCHARGE. JOB NO. 21412 FLOOR SPACE °n INSTALLED AT THE ~ <br /> FOR THE DISHWASHER L _ _ _ _ _ SPACE SHALL BE ZO TACTILE EXIT SIGNS SHALL COMPLY WITH ICC 117.1 CHAPTER 7 REQUIREMENTS INCLUDING RAISED LETTERS AND BRAILLE. PERMIT NO B2404-010 <br /> ORAN MAXIMUM HEIGHTS OFFSET 24"MAX CHARACTER HEIGHT: <br /> ADJACENT SINK. POSSIBLE IN THE 1 24 FROM THE <br /> COMPARTMENT. 52„ CENTERLINE OF 3e-2"TYP REVISIONS: <br /> THE APPLIANCE. <br /> 5A DISHWASHER 56 REFRIGERATOR PLAN VIEW 5C MICROWAVE 45' r <br /> DATE DESCRIPTION <br /> I I 18 min 1 06/28/24 PERMIT REV 1 <br /> REA OF i I 455 <br /> EXIT REFUGE � III I <br /> I --1- - <br /> Z <br /> BRAILLE TO Z <br /> DUPLICATE SIGN TEXT, g centered on ISSUE: <br /> MATCH DIMENSIONS o raised characters 04/01/24 BP PLAN SET <br /> PER ICC A117.1 <br /> TABLE 703.4.3 18 min <br /> 455 <br /> ICC A117.1 FIG.703.3.11-LOCATION OF SIGNS AT DOORS <br /> STANDARD <br /> ADA CODE <br /> SHEET <br /> SHEET NO: <br /> CS9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.