ACCESSIBLE DOORS, HANDRAILS AND RAMPS C/)
<br /> DOORS HANDRAILS RAMPS __' W °'
<br /> ICC A71 .1-2017 �o�
<br /> ICC A11 .1-2017 ICC A71 .1-2017 rn c
<br /> 404.1 GENERAL.DOORS,DOORWAYS AND GATES THAT ARE PART OF AN ACCESSIBLE PULL SIDE PULL SIDE 505.1 GENERAL.HANDRAILS REQUIRED BY SECTION 405.8 FOR RAMPS,SECTION 504.6 405.1 RAMPS ON ACCESSIBLE ROUTES SHALL COMPLY WITH 405. rn LL
<br /> ROUTE SHALL COMPLY WITH 404. __ FOR STAIRS,SECTION 1009.3.3 FOR POOL SLOPED ENTRIES AND SECTION 1009.6.2 FOR m C o
<br /> 11
<br /> 404.2.2 CLEAR WIDTH.DOOR OPENINGS SHALL PROVIDE A CLEAR WIDTH OF 32
<br /> I- I POOL STAIRS SHALL COMPLY WITH SECTION 505. 405.2 RAMP RUNS SHALL HAVE A RUNNING SLOPE GREATER THAN 1:20 AND NOT z m
<br /> Z j 18"MIN. STEEPER THAN 1:12. Q
<br /> INCHES MINIMUM.CLEAR OPENINGS OF DOORWAYS WITH SWINGING DOORS SHALL 2 24"PREFERRED X MIN. 505.2 LOCATION.HANDRAILS SHALL BE PROVIDED ON BOTH SIDES OF STAIRS AND I < � cl
<br /> BE MEASURED BETWEEN THE FACE OF THE DOOR AND THE STOP,WITH THE DOOR ioo } RAMPS. 405.3 CROSS SLOPE.CROSS SLOPE OF RAMP RUNS SHALL NOT BE STEEPER THAN 1:48. J M o m co
<br /> o
<br /> OPEN 90 DEGREES.OPENINGS MORE THAN 24 INCHES DEEP SHALL PROVIDE A CLEAR I w p "
<br /> OPENING OF 36 INCHES MINIMUM.THERE SHALL BE NO PROJECTIONS INTO THE 505.3 CONTINUITY.HANDRAILS SHALL BE CONTINUOUS WITHIN THE FULL LENGTH OF 405.4 FLOOR SURFACES.FLOOR SURFACES OF RAMP RUNS SHALL COMPLY WITH ~
<br /> REQUIRED CLEAR OPENING WIDTH LOWER THAN 34 INCHES ABOVE THE FINISH FLOOR EACH STAIR FLIGHT OR RAMP RUN.INSIDE HANDRAILS ON SWITCHBACK OR DOGLEG SECTION 302.
<br /> OR GROUND.PROJECTIONS INTO THE CLEAR OPENING WIDTH BETWEEN 34 INCHES STAIRS OR RAMPS SHALL BE CONTINUOUS BETWEEN FLIGHTS OR RUNS.OTHER
<br /> AND 80 INCHES ABOVE THE FINISH FLOOR OR GROUND SHALL NOT EXCEED 4 INCHES. NOTE:X=36"MIN.IF Y= HANDRAILS SHALL COMPLY WITH SECTIONS 505.10 AND 307. 405.5 CLEAR WIDTH.THE CLEAR WIDTH OF A RAMP RUN SHALL BE 36 INCHES MINIMUM.
<br /> 60".X=42"MIN.IF Y=54". HANDRAILS AND HANDRAIL SUPPORTS THAT ARE PROVIDED ON THE RAMP RUN SHALL
<br /> 404.2.3 MANEUVERING CLEARANCES.MINIMUM MANEUVERING CLEARANCES AT 505.4 HEIGHT.TOP OF GRIPPING SURFACES OF HANDRAILS SHALL BE 34 INCHES NOT PROJECT INTO THE REQUIRED CLEAR WIDTH OF THE RAMP RUN.
<br /> DOORS AND GATES SHALL COMPLY WITH 404.2.3.MANEUVERING CLEARANCES AND MINIMUM AND 38 INCHES MAXIMUM VERTICALLY ABOVE STAIR NOSINGS,RAMP ocuRKl EARNEs
<br /> SHALL INCLUDE THE FULL CLEAR OPENING WIDTH OF THE DOORWAY AND THE PULL SIDE 4"MIN, PUSH SIDE SURFACES AND WALKING SURFACES.HANDRAILS SHALL BE AT A CONSISTENT HEIGHT 405.6 RISE.THE RISE FOR ANY RAMP RUN SHALL BE 30 INCHES MAXIMUM.
<br /> REQUIRED LATCH-SIDE OR HINGE-SIDE CLEARANCE. 12"MIN.* 2 'MI ABOVE STAIR NOSINGS,RAMP SURFACES AND WALKING SURFACES.
<br /> 404.2.3.1 FLOOR SURFACE.THE FLOOR SURFACE WITHIN THE MANEUVERING r , 405.7 LANDINGS.RAMPS SHALL HAVE LANDINGS AT THE BOTTOM AND TOP OF EACH
<br /> z 1 F-r---r-, 505.5 CLEARANCE.CLEARANCE BETWEEN HANDRAIL GRIPPING SURFACE AND RAMP RUN.LANDINGS SHALL COMPLY WITH SECTION 405.7.
<br /> CLEARANCES SHALL HAVE A SLOPE NOT STEEPER THAN 1:48 AND SHALL COMPLY I z
<br /> � I I I I I I ADJACENT SURFACES SHALL BE 11/2 INCHES MINIMUM. r
<br /> WITH SECTION 302. g
<br /> Bo 405.7.1 LANDINGS SHALL HAVE A SLOPE NOT STEEPER THAN 1:48 AND COMPLY WITH
<br /> N a 505.6 GRIPPING SURFACE.GRIPPING SURFACES SHALL BE CONTINUOUS,WITHOUT SECTION 302.
<br /> SHALL HAVE
<br /> MANEUVERING CLEARANCES COMPLYING WITH TABLE 404.2.3.2. 1 INTERRUPTION BY NEWEL POSTS,OTHER CONSTRUCTION ELEMENTS,OR
<br /> 404.2.3.2 SWINGING DOORS AND GATES.SWINGING DOORS AND GATES OBSTRUCTIONS. Z J
<br /> 405.7.2 WIDTH.CLEAR WIDTH OF LANDINGS SHALL BE AT LEAST AS WIDE AS THE
<br /> LU W WIDEST RAMP RUN LEADING TO THE LANDING. 2 Q
<br /> 404.2.3.3 SLIDING AND FOLDING DOORS.SLIDING DOORS AND FOLDING DOORS SHALL EXCEPTIONS: 1.HANDRAIL BRACKETS OR BALUSTERS ATTACHED TO THE BOTTOM (n
<br /> HAVE MANEUVERING CLEARANCES COMPLYING WITH TABLE 404.2.3.3. SURFACE OF THE HANDRAIL SHALL NOT BE CONSIDERED OBSTRUCTIONS,PROVIDED 405.7.3 LENGTH.LANDINGS SHALL HAVE A CLEAR LENGTH OF 60 INCHES MINIMUM. O I-
<br /> THE BRACKETS OR BALUSTERS COMPLY WITH THE FOLLOWING CRITERIA: ry- 2E W Q
<br /> 404.2.4 THRESHOLDS.IF PROVIDED,THRESHOLDS AT DOORWAYS SHALL BE 1/2 INCH NOTE:Y=54"MIN. NOTE:Y=48"MIN.IF DOOR HAS 1.1.NOT MORE THAN 20 PERCENT OF THE HANDRAIL LENGTH IS OBSTRUCTED;1.2. 405.7.4 CHANGE IN DIRECTION.RAMPS THAT CHANGE DIRECTION BETWEEN RUNS AT Q w
<br /> MAXIMUM IN HEIGHT.RAISED THRESHOLDS AND CHANGES IN LEVEL AT DOORWAYS IF DOOR HAS CLOSER BOTH A LATCH AND A CLOSER. HORIZONTAL PROJECTIONS BEYOND THE SIDES OF THE HANDRAIL OCCUR 11/2 INCHES LANDINGS SHALL HAVE A CLEAR LANDING 60 INCHES MINIMUM BY 60 INCHES MINIMUM. a
<br /> SHALL COMPLY WITH SECTIONS 302 AND 303. MINIMUM BELOW THE BOTTOM OF THE HANDRAIL,AND PROVIDED THAT FOR EACH 1/2 F-
<br /> `IF BOTH CLOSER AND LATCH Q F_
<br /> PROVIDED. INCH OF ADDITIONAL HANDRAIL PERIMETER DIMENSION ABOVE 4 INCHES,THE VERTICAL 405.7.5 DOORWAYS.WHERE A DOOR OR GATE IS ADJACENT TO A RAMP LANDING, W
<br /> 404.2.6 DOOR AND GATE HARDWARE.HANDLES,PULLS,LATCHES,LOCKS,AND OTHER CLEARANCE DIMENSION OF 11/2 INCH SHALL BE PERMITTED TO BE REDUCED BY 1/8 MANEUVERING CLEARANCES REQUIRED BY SECTIONS 404.2.3 AND 404.3.4 SHALL BE CO � � W
<br /> OPERABLE PARTS ON ACCESSIBLE DOORS AND GATES SHALL HAVE A SHAPE THAT IS INCH,AND;1.3.EDGES SHALL BE ROUNDED. PERMITTED TO OVERLAP THE LANDING AREA.WHERE A DOOR OR GATE THAT IS
<br /> EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, 24" SUBJECT TO LOCKING IS LOCATED ADJACENT TO A RAMP LANDING,THE LANDING SHALL -
<br /> PINCHING,OR TWISTING OF THE WRIST TO OPERATE. PUSH SIDE(X) MIN. 505.7 CROSS SECTION.HANDRAILS SHALL HAVE A CROSS SECTION COMPLYING WITH BE SIZED TO PROVIDE A TURNING SPACE COMPLYING WITH SECTION 304.3. U 0 >
<br /> PUSH SIDE SECTION 505.7.1 OR 505.7.2. _ LLJ
<br /> 404.2.6.1 HARDWARE HEIGHT.OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34 -- m CD
<br /> r T--� r- - --� 405.8 HANDRAILS.RAMP RUNS WITH A RISE GREATER THAN 6 INCHES SHALL HAVE
<br /> INCHES MINIMUM AND 48 INCHES MAXIMUM ABOVE THE FLOOR.WHERE SLIDING I 1 Z 505.7.1 CIRCULAR CROSS SECTION.HANDRAILS WITH A CIRCULAR CROSS SECTION HANDRAILS COMPLYING WITH SECTION 505. Lu
<br /> DOORS ARE IN THE FULLY OPEN POSITION,OPERATING HARDWARE SHALL BE SHALL HAVE AN OUTSIDE DIAMETER OF 11/4 INCHES MINIMUM AND 2 INCHES MAXIMUM. J
<br /> EXPOSED AND USABLE FROM BOTH SIDES. I I iv
<br /> 405.9 EDGE PROTECTION.EDGE PROTECTION COMPLYING WITH SECTION 405.9.1 OR U
<br /> v 1 1 505.7.2 NONCIRCULAR CROSS SECTIONS.HANDRAILS WITH A NONCIRCULAR CROSS 405.9.2 SHALL BE PROVIDED ON EACH SIDE OF RAMP RUNS AND AT EACH SIDE OF RAMP Q
<br /> 404.2.7.1 DOOR AND GATE CLOSERS.DOOR AND GATE CLOSERS SHALL BE ADJUSTED SECTION SHALL HAVE A PERIMETER DIMENSION OF 4 INCHES MINIMUM AND 61/4 INCHES LANDINGS. I
<br /> SO THAT FROM AN OPEN POSITION OF 90 DEGREES,THE TIME REQUIRED TO MOVE MAXIMUM,AND A CROSS-SECTION DIMENSION OF 21/4 INCHES MAXIMUM. U
<br /> THE DOOR OR GATE TO AN OPEN POSITION OF 12 DEGREES SHALL BE 5 SECONDS 405.9.1 EXTENDED FLOOR SURFACE.THE FLOOR SURFACE OF RAMP RUNS AND RAMP
<br /> MINIMUM. 505.8 SURFACES.HANDRAILS,AND ANY WALL OR OTHER SURFACES ADJACENT TO LANDINGS SHALL EXTEND 12 INCHES MINIMUM BEYOND THE INSIDE FACE OF A RAILING
<br /> THEM,SHALL BE FREE OF ANY SHARP OR ABRASIVE ELEMENTS.EDGES SHALL BE COMPLYING WITH SECTION 505.
<br /> 404.2.7.2 SPRING HINGES.DOOR AND GATE SPRING HINGES SHALL BE ADJUSTED SO ROUNDED.
<br /> THAT FROM AN OPEN POSITION OF 70 DEGREES,THE DOOR OR GATE SHALL MOVE TO NOTE:X=12"MIN.IF DOOR HAS NOTE:Y=48"MIN.IF DOOR HAS 405.9.2 CURB OR BARRIER.A CURB COMPLYING WITH SECTION 405.9.2.1 OR A BARRIER
<br /> THE CLOSED POSITION IN 1.5 SECONDS MIN. BOTH A LATCH AND A CLOSER BOTH A LATCH AND A CLOSER 505.9 FITTINGS.HANDRAILS SHALL NOT ROTATE WITHIN THEIR FITTINGS. COMPLYING WITH SECTION 405.9.2.2 SHALL BE PROVIDED.
<br /> 404.2.8 DOOR-OPENING FORCE.FIRE DOORS AND DOORS OR GATES REQUIRED TO BE 505.10 HANDRAIL EXTENSIONS.HANDRAILS SHALL EXTEND BEYOND AND IN THE SAME 405.9.2.1 CURB.A CURB SHALL BE A MINIMUM OF 4 INCHES IN HEIGHT.
<br /> EQUIPPED WITH PANIC HARDWARE,BREAK AWAY FEATURES OR OTHER FACTORS 2"MIN DIRECTION OF STAIR FLIGHTS AND RAMP RUNS IN ACCORDANCE WITH SECTION 505.10.
<br /> REQUIRING HIGHER OPENING FORCE FOR SAFETY REASONS SHALL HAVE THE CLEA 405.9.2.2 BARRIER.BARRIERS SHALL BE CONSTRUCTED SO THAT THE BARRIER
<br /> MINIMUM OPENING FORCE ALLOWABLE IN SCOPING PROVISIONS ADOPTED BY THE CLEAR OPENINGS MUST BE BETWEEN THE EXCEPTIONS: 1.CONTINUOUS HANDRAILS AT THE INSIDE TURN OF STAIRS AND RAMPS, PREVENTS THE PASSAGE OF A 4-INCH DIAMETER SPHERE WHERE ANY PORTION OF THE
<br /> APPROPRIATE ADMINISTRATIVE AUTHORITY.FOR OTHER DOORS OR GATES,THE FLOOR IN ITS 90 DEGREE OPEN POSITION AND SPHERE IS WITHIN 4 INCHES OF THE FLOOR.
<br /> FORCE FOR PUSHING OR PULLING OPEN DOORS OR GATES SHALL BE AS FOLLOWS: THE FACE OF THE STOP 505.10.1 TOP AND BOTTOM EXTENSION AT RAMPS.RAMP HANDRAILS SHALL EXTEND
<br /> 1.INTERIOR HINGED DOOR:5.0 POUNDS MAXIMUM;2.INTERIOR SLIDING OR FOLDING 90 HORIZONTALLY ABOVE THE LANDING 12 INCHES MINIMUM BEYOND THE TOP AND 405.10 LANDINGS SUBJECT TO WET CONDITIONS SHALL BE DESIGNED TO PREVENT THE
<br /> DOORS:5.0 POUNDS MAXIMUM;3.EXTERIOR HINGED,SLIDING OR FOLDING DOOR:10 BOTTOM OF RAMP RUNS.EXTENSIONS SHALL RETURN TO A WALL,GUARD,OR FLOOR, ACCUMULATION OF WATER.
<br /> POUNDS MAXIMUM. STOP OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN ADJACENT RAMP RUN.
<br /> sett
<br /> NOTE:ALL DOORS IN ALCOVES SHALL COMPLY WITH THE REGISTERED
<br /> 404.2.9 DOOR AND GATE SURFACE.DOOR AND GATE SURFACES WITHIN 10 INCHES OF 505.10.2 TOP EXTENSION AT STAIRS.AT THE TOP OF A STAIR FLIGHT,HANDRAILS SHALL ARCHITECT
<br /> THE FLOOR,MEASURED VERTICALLY,SHALL BE SMOOTH SURFACES ON THE PUSH CLEARANCES FOR FRONT APPROACHES. EXTEND HORIZONTALLY ABOVE THE LANDING FOR 12 INCHES MINIMUM BEGINNING U..),sclI('` cl_ _
<br /> SIDE EXTENDING THE FULL WIDTH OF THE DOOR OR GATE.DOOR AND GATE DIRECTLY ABOVE THE LANDING NOSING.EXTENSIONS SHALL RETURN TO A WALL,
<br /> HARDWARE OR ANY OTHER OBSTRUCTION OR PROTRUSION SHALL NOT BE MOUNTED GUARD,OR THE LANDING SURFACE,OR SHALL BE CONTINUOUS TO THE HANDRAIL OF w.eco cuRK
<br /> IN NOR EXTEND INTO THE AREA WITHIN 10 INCHES OF THE FLOOR.PARTS CREATING 1.THE FLOOR OR LANDING ON EA.SIDE OF AN EXIT DOOR SHALL BE LEVEL srATE or wgaHlNc oN
<br /> AND CLEAR.THE LEVEL AREA SHALL HAVE A LENGTH IN THE DIRECTION OF AN ADJACENT STAIR FLIGHT.
<br /> HORIZONTAL VERTICAL JOINTS SUCH SURFACES SHALL BE WITHIN 1/16 INCH THE DOOR SWING OF AT LEAST 60"AND LENGTH OPPOSITE THE DIRECTION
<br /> THE SAME PLANE AS THE OTHER.CAVITIES CREATED BY ADDED KICK PLATES SHALLL OF DOOR SWING 44"AS MEASURED AT RIGHT ANGLES TO THE PLANE OF 505.10.3 BOTTOM EXTENSION AT STAIRS.AT THE BOTTOM OF A STAIR FLIGHT,
<br /> BE CAPPED. THE FLOOR IN ITS CLOSED POSITION. HANDRAILS SHALL EXTEND AT THE SLOPE OF THE STAIR FLIGHT FOR A HORIZONTAL DATE: 12/14/23
<br /> DISTANCE EQUAL TO ONE TREAD DEPTH BEYOND THE BOTTOM TREAD NOSING.
<br /> 404.2.10 VISION LITES.DOORS,GATES AND SIDELITES ADJACENT TO DOORS OR EXTENSIONS SHALL RETURN TO A WALL,GUARD,OR THE LANDING SURFACE,OR SHALL JOB NO. 23-011
<br /> GATES CONTAINING ONE OR MORE GLAZING PANELS THAT PERMIT VIEWING 2.THE WIDTH OF THE LEVEL AREA ON THE SIDE TO WHICH THE DOOR BE CONTINUOUS TO THE HANDRAIL OF AN ADJACENT STAIR FLIGHT. PERMIT NO. B2404-010
<br /> THROUGH THE PANELS SHALL HAVE THE BOTTOM OF AT LEAST ONE PANEL ON SWINGS SHALL EXTEND 24"PAST THE STRIKE EDGE OF THE DOOR FOR
<br /> EITHER THE DOOR,GATE OR AN ADJACENT SIDELITE 43 INCHES MAXIMUM ABOVE THE EXTERIOR DOORS AND 18"PAST THE STRIKE EDGE FOR INTERIOR DOORS. 505.7 CROSS SECTION DIAGRAMS: REVISIONS:
<br /> FLOOR.
<br /> REQUIRED-1 NOTE:PROVIDE BUMPER IN CIRCULAR
<br /> 404.3.3 CLEAR WIDTH.DOORWAYS SHALL HAVE A CLEAR OPENING WIDTH OF 32 I CLEAR I POCKET TO PREVENT DOOR DATE DESCRIPTION
<br /> INCHES IN POWER-ON AND POWER-OFF MODE.THE MINIMUM CLEAR OPENING FOR ISPACE 1 18"MIN. FROM FULLY RECEDING 1 06/28/24 PERMITREV 1
<br /> AUTOMATIC DOOR SYSTEMS SHALL BE BASED ON THE CLEAR OPENING WIDTH 24"PREFERRED 2"MIN
<br /> PROVIDED WITH ALL LEAFS IN THE OPEN POSITION.
<br /> 1-1/4"-2" 1-1/2"min
<br /> TABLE 404.2.3.2-MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS&GATES REQUIRED
<br /> CLEAR NOTE:X= STOP
<br /> TYPE OF USE MINIMUM CLEARANCES WITH CLOSER
<br /> APPROACH PERPENDICULAR TO BEYOND LATCH SPACE AND LATCHSET 1-1/2"min ISSUE
<br /> DIRECTION DOOR SIDE DOORWAY PARALLEL TO DOOR 04/01/24 BP PLAN SET
<br /> ALL LEVEL DOOR HANDLES ARE TO OPERATE AT A FORCE NO GREATER THAN
<br /> FROM FRONT PULL 60 INCHES(1525 MM) 18 INCHES(455 MM) A 5LB.FORCE AND WITHOUT EXCESSIVE BODY MOVEMENT OR SPECIAL
<br /> KNOWLEDGE.LEVELS TO BE OPERABLE WITH ONE HAND AND NOT REQUIRE
<br /> FROM FRONT PUSH 52 INCHES(1320 MM)6 0 INCHES(0 MM)' GRASPING,PINCHING OR TWISTING.DOORS TO SWING AND BE OPERABLE AT
<br /> A FORCE NO GREATER THAN 5LB.ALL DOORS MUST PROVIDE MINIMUM
<br /> FROM HINGED SIDE PULL 60 INCHES(1525 MM) 36 INCHES(915 MM) MANEUVERING CLEARANCES.
<br /> FROM HINGED SIDE PULL 54 INCHES(1370 MM) 42 INCHES(1065 MM) NONCIRCULAR Rounded edges
<br /> AUTOMATIC CLOSER ADA DOOR,
<br /> FROM HINGED SIDE PUSH 42 INCHES(1065 MM)' 22 INCHES(1370 MM)4 (IF NEC) HANDRAILS &
<br /> ROOM IDENTIFICATION 2
<br /> FROM LATCH SIDE PULL 48 INCHES(1220 MM)2 24 INCHES(610 MM) (IF NEC) %, 1-1/2"min RAMPS
<br /> FROM LATCH SIDE PUSH 42 INCHES(1065 MM)2 24 INCHES(610 MM) VIEWING PANEL
<br /> (IF NEC)
<br /> 'ADD 6 INCHES(150 MM)IF CLOSER AND LATCH PROVIDED. LEVEL DOOR HANDLE 4 4"-6-1/4"perimeter SHEET NO:
<br /> 2 ADD 6 INCHES(150 MM)IF CLOSER PROVIDED. = M
<br /> 3ADD 12 INCHES(305 MM)BEYOND LATCH IF CLOSER AND LATCH PROVIDED. NOTE:THRESHOLD !?
<br /> 4 BEYOND HINGE SIDE. MAX.HT.1/2"A.F.F. ------ ^ O
<br /> 61N EXISTING BUILDINGS&FACILITIES,THE DIMENSION PERPENDICULAR TO THE 1-1/2"min CV`
<br /> DOOR OR GATE FOR THE FRONT DIRECTION ON THE PUSH SIDE SHALL BE 48 NOTE:FLOOR MAT FLUSH 2"MIN. (less 1/e"for each 1/2"additional
<br /> INCHES(1220 MM)MINIMUM. WITH FINISHED FLOOR q Iperimeter dimension above 4!')
<br />
|