Laserfiche WebLink
e <br /> WINDOW FLASHING INSTALLATION SEQUENCE WEATHER RESISTIVE BARRIER INSTALLATION <br /> NOTES: <br /> NOTES: -LD <br /> 1. W.R.B.INSTALLATION SHOWN IS BASED ON FORTIBER <br /> 1. WINDOW FLASHING SEQUENCE SHOWN IS BASED ON BUILDING SYSTEM'S 2 PLY SUPER JUMBO TEX 60 MIN.SYSTEM. <br /> FORTIBER BUILDING SYSTEM'S HIGH PERFORMANCE WIINDOW INSTALL ALL INDICATED PRODUCTS IN CONFORMANCE WITH <br /> -- FLASHING SYSTEM.INSTALL ALL INDICATED PRODUCTS IN MANUFACTURER'S RECOMMENDATIONS&REQUIREMENTS. <br /> REGI;TERED CONFORMANCE WITH MANUFACTURER'S RECOMMENDATIONS <br /> ARCy CT &REQUIREMENTS. <br /> C / 2. INSTALLATION SEQUENCE IS DESIGNED FOR INTEGRAL I- <br /> (-% FLANGED WINDOW APPLICATIONS,WHERE WINDOW IS H <br /> iHaer(" nnou' INSTALLED BEFORE THE WEATHER RESISTIVE BARRIER IS < <br /> scar_�FNAi4iNcira APPLIED <br /> l � <br /> 0 <br /> WRB CONT.BEHIND u m <br /> '> a <br /> THE UNDERSIGNED HAS PROVIDED BUILDING THRU-WALL FLASHINGS <br /> z a <br /> ENCLOSURE DOCUMENTS THAT IN MY EXTEND 6' OMINIMUM ABOVE WR13 LAPS <br /> PROFESSIONAL JUDGEMENT ARE APPROPRIATE <br /> - <br /> TO SATISFY THE REQUIREMENTS OF RCW TOP OF ROUGH THRU-WALL O <br /> 64.55.005 THROUGH 64.55.090 —ALIGN FLUSH WITH <br /> OPENING FLASHINGS <br /> UGH OPEN NG SILL, a�m <br /> LEAVE BOTTOM EDGE EXTEND 12" 72� <br /> FREE.EXTEND 12" MINIMUM BELOW <br /> MIN.BEYOND JAMB <br /> BOTTOM OF <br /> EDGE BOTH SIDES. <br /> ROUGH OPENING;LEAVE FLASHING _ a <br /> FREE AT BOTTOM g w S t> <br /> N <br /> WASHINGTON STATE PROFESSIONAL STAMP <br /> O <br /> N.T.S. - w o 0 <br /> 7o seal the W.R.B.around all electrical, CUT HOLE FOR METAL VENT `\ <br /> HVAC,plumbing or other penetrations: I- SIZE <br /> PENETRATION SHROUD 6"MIN. <br /> 1.Fill open gaps with low expansion foam pVERCAL a—w.slant 1. INSTALL 9"MOISTOP PF 2. INSTALL 9"MOISTOP PF rFLASHING PRESTRIP AT FLASHING PRESTRIP AT <br /> 2.After the foam sealant has hardened, BASE SILL JAMBS <br /> trim off any excess matenal. W.R.B. <br /> (IF PRE-STRIPPED, 4,01' <br /> PPLY 6"STRIPS <br /> 3.Flash around the penetration with an TO BE 1Z' S.AM.OVER <br /> aPP <br /> roved sealant,S.A.M.or preformed EACH DIRECTION) THE FLANGE <br /> accessones made for this purpose ONTO W.R.B. <br /> A When using tape or flashing start at the <br /> bottom of each penetration. SEALANT x' <br /> a.After the first layer,apply sealant over BETWEENSF217 .AM. <br /> the slit'n the flashing. W.R.B.PRE-STRIP <br /> C.Sh ngle another layer of flashing over 8 FIELD W.R.B. <br /> AT HEAD THRU-WALL FLASHINGS <br /> the bottom layers for proper dra nage FIELD W.R.B.AT AT FLOORLINES AND 1 <br /> HEAD WHERE INDICATED 2"WEAVE A7 OUTSIDE <br /> 4.Apply the weather resistive barrier over :. ,P, CORNERS PER MFR. <br /> the flashed penetration. TAPE PRE-STRIP P TO INSTALL LLI LLI i <br /> T _ <br /> Products with flanges should be integrated L FIELD W.R.B.AT METAL HOOD 7 2 <br /> into the air banner system using S.AM. ,ri�..'� JAMBS AND L.L <br /> Follow shingle lapping procedures and SILLS(TYP.) <br /> CONT.THRU-WALL w <br /> sequencing as in a window installation FIELD W.R.B. O FLASHING AT BASE <br /> Q TUCKED UNDER ® M <br /> See detail for hood fabrication. W.R.B.PRE- LLJ <br /> STRIP AT SILL& <br /> JAMBS <br /> CONTINUOUS <br /> 2 PENETRATION FLASHING BEAD OF SEALANT <br /> N.T.S. s <br /> OEXTEND 3"MINIMUM BEYOND EXTEND 3"MINIMUM <br /> TOP AND BOTTOM EDGES OF BEYOND EDGE OF <br /> 5 WINDOW FLANGE PRESTRIPPING <br /> i f <br /> FASTEN THROUGH RETURN <br /> 3. APPLY 3/8"BEAD OF W <br /> 1/2"TIGHT HEM ON MOISTOP SEALANT TO THE rY <br /> PAN UPSTAND 4, 4" BACKSIDE OF WINDOW LL <br /> MOUNTING FLANGE Q O J <br /> 4. INSTALL WINDOW INTO m <br /> ROUGH OPENING PER C = <br /> rOpT WINDOW MFR.'S L <br /> / RECOMMENDATIONS m <br /> 00 <br /> 5. WIPECLEANWINDOW <br /> FLANG IAND TO PREP 6. INSTALL 6"MOISTOP E- 7. INSTALL 12"MOISTOP E-Z SEALPREST V J W <br /> FOR SUBSEQUENT Z SEAL OVER JAMB WINDOW HEAD,LAPPING OVER Q <br /> SSP�O QED` FLASHING WINDOW FLANGES AND JGEALING TO TOP OF WINDOW ; cc <br /> IR �O�5 O W U <br /> LL <br /> DF 11 a U <br /> a <br /> NOTES W/y'� <br /> 1.MATERIAL TO BE 24 GA GALV. W <br /> STEEL COORDINATE <br /> 2.SEAMS TO BE SOLDERED DIMENSION OF <br /> LOWER FLASHING \ ' <br /> LEG W/OPERATION <br /> OF WINDOW/DOOR j <br /> i <br /> METAL SILL PAN,TYP.AT EXTR.DOORS FOLDED,UNBROKEN <br /> i END DAM <br /> N.T.S. <br /> E � <br /> HEAD DEPTH VARIES <br /> 4 �8. <br /> LAP WEATHER <br /> BARRIER OVER <br /> HEAD FLASHING <br /> 10. <br /> JOB NO.: <br /> 22205 <br /> TO PIT <br /> TOx� 1/2"MIN. PLOT DATE <br /> m (2"PREF.) 12/5/2023 227:07 PM <br /> 1/2"DRIP EDGE <br /> N Mva l WITH 3/8"HEM E DATE: 06/08/2023 <br /> \Q SCALE: As indicated <br /> 8. INSTALL FREFINISHED METAL 9. INSTALL WEATHER 10. CONTINUE INSTALLING f DRAWN: MIS <br /> FLASHING BARRIER STARTING WEATHER BARRIER IN <br /> _ FROM BASE OF WEATHERBOARD FASHION,LAP CHCKD: TM <br /> 1NMATERIAL TO BE 24GA OR HEAVIER GALV.OR PRE- WALL;TUCK UNDER COURSE OVER HEAD FLASHING ` GENERAL SHEETS <br /> FINISHED STEEL PRESTRIPPING AT SHEET NO.: <br /> 2.END DAMS TO BE BENT AND CRIMPED. SILL - <br /> HEAD FLASHING,TYP.@ DOOR&WINDOW WEATHER BARRIER INSTALLATION L A18 <br /> ? N.T.S. 12„=1,-0„ <br />