My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9502 18TH AVE W H 2023 Plans 2025-02-03
>
Address Records
>
18TH AVE W
>
9502
>
Plans
>
9502 18TH AVE W H 2023 Plans 2025-02-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/3/2025 9:25:21 AM
Creation date
1/27/2025 7:00:21 AM
Metadata
Fields
Template:
Address Document
Street Name
18TH AVE W
Street Number
9502
Unit
H
Permit
B2310-047
Year
2023
Notes
NEW SFR - REF RB2306-001 - Unit H
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FLOOR PLAN NOTES <br /> L CONTRACTOR SHALL VERIFY ALL NOTES,MATERIALS t CONDITIONS PRIOR TO - <br /> CON5TRUCTON. EQ. EQ A <br /> WINDOWS 4 DCORS: I OPERABLE. 5GD ReR PLAN FIXED DOOR t.IAMB <br /> pAtlEL I CAULK BACK OF PANEL WRAP NERVASTRAL <br /> 2. ALL EXTERIOR WINDOW t DOOR HEADERS TO BE INSULATED w/k-10 INSULATION. P THRESHOLD TO <br /> F�� I <br /> 3. WINDOWS t DOORS ARE SHOWN t NOTED AS NOMINAL SIZES. NERVESTRAL UP.IAMB b" <br /> Ill <br /> 4. WINDOW HEAD HEIGHT R.O.SHOWN PER ELEVATIONS. EGRESS WINDOW SILL HEIGHT R.O.@ '.VE5rRAI. - --' --1 "' '----:1 av HEARTH=CEDAR TRIM, <br /> --.'NINU I �Fb.ALL SIDES,CAUWSEAL t ALL SEAMS BEADS MAX.42°A.F.F. EQ. � i EQ. ((AUK UNDER OF <br /> 5. ALL WOOD IN CONTACT WITH CONIC,TO BE PRE55URE TREATED. To"of CAULK UNDER <br /> (I) <br /> 6. EXTERIOR WALL5 TO BE 2x6 STUDS @ 16 O.C.,U.NO. IN. I -.j - 1 3Pam AGAINSTttP. - <br /> NERJAST @ SIDES OF JAMB <br /> 7. GARAGE DOOR HEADERS @ 84'A.F.F. WRAP EDGE t <br /> fRavr PORCH PATIO THRESHOLD <br /> 8. EXTERIOR SWING DOOR <br /> R HEADERS @ 83 A.F.F.1/2'A.F.F. 3'-0 LANDING TYP. ADD'L NERVASTRAL NERVA5TRAL OR EQ <br /> 9. INTERIOR SWING DOOR HEADERS @ 83'A.F e"rx PAra,suaun ururs '�-- <br /> @ BACK PATO's Q. gram Ix rxe aaeaxW 17'-0' 13'-0' <br /> 10. SWING DOORS TO FOLLOW CENTERLINE DIMENSION IN PLANS 4R BE 3"hIIN.Or!HINGE SIDE. a rNE fLYEo smf W rNF ��THRESHOLD DETAIL <br /> 11. GARAGE-TO-HOUSE DOOR TO BE A SOLID W00D IV THICK 20-MINUTE FIRE-RATED DOOR scn.aENEVFR"'�'�E Tin <br /> w/A SELF CL051NG HARDWARE DEVICE, n 26 HEARTWOOD CEDAR TRIM L-I SCALE: 1-1/2'=1'-0" I7'-0' 4'-0' V-0' 4'-0' <br /> 12. PER R311.3.i:THE LANDING OR FLOOR ON THE EXTERIOR SIDE OF ALL EXTERIOR DOORS rHREstIaD l��FLANDING AGAN NNa�PLAW FOR <br /> vE57Ra <br /> EXCEPT THE FRONT DOOR SHALL BE NOT MORE THAN 7-3/4'BELOW THE TOP OF THE 2xs IEARTHOOD CEDAR 5'-1I 6'_0' - <br /> _____________ HOIIS INTERSECTION, <br /> 2 24'x36°HEAT Cl <br /> THRESHOLD PROVIDED THE DOUR DOES N�SWING OVER THE LANDING OR FLOOR NERVFsrRAI HOUSE INTERSECTION, PUMP BASE. 11 '1 11 13. ALL BI-FOLD 4 BI-PASS DOORS TO BE CENTERED,U N.O. -uNUNG PER PLAN WHERE accuRs WHEN GARAGE t--t--L <br /> -(MIN.3STE TYPO - - W12 OPT.SELECTED, Z MING: 51 OF CONDITIONS <br /> aD BY <br /> tUD SILL SITE OONDI'FIONS - - I LINE a NEk/ESTRAL D� 4 VERIFY LOCATION <br /> 14. VERIFY FIREPLACE STYLE t LOCATION w/SUPERVISOR PRIOR TO CON5T. - _ 3'x4 CONC. �w/517E SUPER <br /> slAe a!GRADE LANDING ( ��l <br /> 15. FRAMERS TO INSTALL ALL WINDOWS t INTERIOR COLUMNS a+c�wuL - I ^1 5040� <br /> 17. TOWEL RING LK'C P 6'A.F.F. .i1 -- s� mart caaa <br /> 17. TOWEL BAR BLK'G @ 4B°A.F.F.4 BLOCK BOTH BAYS. <br /> I8. TOILET PAPER HOLDER BLK'G @ 22'A.F.F.AND 42'FROM BACK WALL WHERE POSSIBLE -" O <br /> 19. TWERN05TAT BLK'G @ 60'A.F1 EXT. LANDING DETAIL @ p �5OFFIT TO BTM OUTDOOR 3'-0� « LJ--1 <br /> 20. EXTERIOR LIGHT BLOCKS AT ALL FRONT ENTRY'S SHALL BE INSTALLED AT"-6'A.F.F. I� SLIDING GLASS DOOR, TYI OF BM,TYP I 3 a o v <br /> I7 Ox5 0 <br /> 21. THE TOP OF THE EXTERIOR LIGHT BLOCKS AT GARAGE SHALL ALIGt!WITH TOP OF THE r � v <br /> GARAGE DOUR TRIM YV I L SCALE:N.T.S. 6040 XOX NOOK , <br /> 22. ADD CgJT,BLOCKING FOR STAIR HANDRAIL BRACKETS �l <br /> 23. STAIRS w/WINDER STEPS WILL ALWAYS HAVE A CONTINUOUS HANDRAIL INSTALLED ON 10'X12' - ^, <br /> THE INSIDE OF THE STAIR's RUN CST ' f <br /> _ 24. LADDER-BLOCK AT EXTERIOR WALLS AS NECESSARY FOR INSULATION INSTAL EQ 11 EQ. LU <br /> 7' _1 <br /> VENTILATION: 3'-9. 2we 4'-0" 2�42 INSTALL(2) <br /> 25. WHOLE HOUSE VENTILATION SHALL BE PROVIDED BY A CENTRAL EXHAUST FAN IN FRONT°OOR PER Pam__.--_1 ---- 2CM OVERHANGS TO BE 8't 2x6 STACKED <br /> ACCORDANCE WITH 1115054.1E - -- � -- 3CM OVERHANGS TO BE 12° o <br /> ® I- BLKNG FOR <br /> 26. WHOLE HOUSE FAN SHALL OPERATE CONTINUOUSLY. _ "' _ RANGE HOOD <br /> 27. WHOLE HOUSE FAN CFM RATE BASED ON TABLE M1505.4.3(I).EXAMPLE:7C C-M=0R 2600 FRart p25 a>< ' OF CENTER <br /> 5F HOME w;4 BEDROOMS,AND THEN INCREASE BY FACTOR OF 15 PER TABLE 4'-0' I D/W DW AIR <br /> ELEVATION 12 STUD @+65' <br /> MI5054.3(2)TO ACCOUNT FOR NOT-BALANCED,NOT-DISTRIBUTED VENTILATION SYSTEM o ELECTRIC _ GREAT ROOM z L GAP, DW <br /> 28. WHOLE <br /> CFM/HOUSE <br /> EWATT PFA SEAL BE 1.,0 SONES OR LESS,AND 54IALL HAVE AN EFFICACY OF 2 8 Ralsm waLL COCK THRESHOLD (z)u+§To BE in FIREPLACE '-" 1514xl71 � �� e o SIDE I <br /> RIPPED TO"6' _. RB'IWFD PRIOR UNt ,,r\ O <br /> 2tB PLATE @ 2x H.K. <br /> TO FRONT `.�i.> 1 0 O I ��/ <br /> 29. FRESH AIR SHALL I INTRODUCED INTO THE HOUSE VIA OPERABLE WO1DOFi5 PER STATE <br /> 'S19-FLOOR 10E KKK - STEPhULK BENG <br /> CODE INTERPRETATION 17-15. @ DocR wImED - �'> ® CENTER ILA- <br /> WHOLE I__L <br /> 30. PROVIDE A FRESH AIR TRANSFER GRILL ABOVE DOUR HEADER IN THE ROOM WITH THE PEk - s g®� STUD BAY <br /> WHOLE HOUSE FAN DG PAPER _ ,' '�"a - E ON RANGE ' _ <br /> 31. PER IRC M50245:WHERE THE DRYER VENT EXHAUST DUCT 15 CONCEALED WITHIN THE FAN"ITSEE CAB <br /> - <br /> BUILDING CONSTRUCTION,THE EQUIVALENT LENGTH OF THE EXHAUST DUCT SHALL BE -iD t CONIC, „�. OPT KITCHEN ' LAYOUT - <br /> IDENTIFIED ON A PERMANENT LABEL OR TAG. THE LABEL OR TAG SHALL BE LOCATED puietsTEM FRorvT ,T.O.RA15ED _ RUN FAN 10'6x12'3 FOR LOC. <br /> Wp11 BEYOND .FRONT PORCH POROH STEM WALL TO DUCT TO 3'-IIV2" 6'-QVT' T-5Z° m 4'-III" 7'7°WITHIN 6FT OF THE EXHAUST DUCT CONNECTION. RAI SLAB.SLOPE STETf ' '� <br /> STEM <br /> � Y'PER LM. yIALL x T.O.FRONT PORCH TOILET ar 1 x Y <br /> SEGTIOII WALL, fT STETI WALL=7' SINK WALL 2x6 WALL MINI-SPLIT 0 BF I t---1-J <br /> LIFE 5AFETY: DOWN THRU <br /> 26. A HEAT ALARM OR HEAT DETECTOR RATED FOR AMBIENT OUTDOOR TEMPEZATURE5 AND CRAWL REFER 1 <br /> HUMIDITY TO BE CENTRALLY LOCATED IN THE GARAGE. il1A FRONT PORCH EXT. DETAIL - - - -I QR_ _____--- <br /> 27. THE HEAT ALARM OR HEAT DETECTOR WILL BE CONNECTED TO AN ALARM OR SMOKE ELECTRIC o _ SPACE t ", _ W/5(3) OppNIG <br /> ALARM THAT 15 INSTALLED IN THE DWELLING AND LOCATED IN A NALLWAI, ROOM OR SCALE:I/2'=I'-0' VENT TO SD/CO <br /> OUTSIDE - <br /> OTHER LCCATIIX!THAT WILL PROVIDE OCCUPANT NOTIFICATION FIREPLACE OPT. 266E i 4 y®� HINT TO BE - <br /> 10. SMOKE DETECTORS TO BE IIOV,INTERCONNECTED,w/BATTERY BACKUP i CENT-RALLY 'P _ WH,3' INSTALLED IN p <br /> 1p <br /> LOCATED IN EACH HABITABLE ROOM. ADDITIONAL SMOKE DETECTORS SHALL BE co - 5N x TP DR 'ro K /LR\ THE 3rd CAR i--t-1 <br /> INSTALLED WHERE THERE 15 A CEILING HEIGHT CHANGE GREATER THAN 24 SCALE: V4'=I'-0' 1 IT" 286E GARAGE OR <br /> I. SMOKE DETECTORS SHALL BE INSTALLED NOT LESS THAN 3 FT HORIZONTALLT FROM THE 3 6 -/ GARAGE \ <br /> 4"BOLLARD / 27' <br /> DOOR OR OPENING OF A BATHROOM THAT CONTAINS TUB q2 SHOWER.[R3171 _ T BUMP-OUT WHEN <br /> 12. IONIZATION SMOKE ALARMS: - - LINE OF THAT OPT IS <br /> + SHALL NOT BE INSTALLED LE55 THAN 20 FT HORIZONTALLY FROM A PERMANENTLY FLR ABV SELECTED, <br /> INSTALLED COCKING APPLIANCE. <br /> t IONIZATION SMOKE ALARMS WITH AN ALARM-SILENCING SWITCH SHALL NOT BE INSTALLED <br /> LESS THAN III FT HORIZONTALLY FROM A PERMANENTLY INSTALLED COKING APPLIANCE. CPTN <br /> 24. PHOTO ELECTRIC SMOKE ALARMS SHALL NOT BE INSTALLED LESS THAN 6 FT 246E GARAGE <br /> w <br /> HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING APPLIANCE CR3141 <br /> 25.GARAGE NOTE:WRAP ALL WARM WALLS AND SUPPORTING MEMBERS WITH 1/2'G.W.B.t 5/B° ~rc I9 IXIq 7 <br /> IB5Q4"CRAWL - p COPYRIGHT NOTICE:THIS <br /> TYPE'X'ON THE CEILING,POLY SEAL RIM,ENTIRE GARAGE TO MEET JURISDICTION - N - SPACE ACCESS �' GARAGE NOTE:WRAP ALL WARM RIlG Is OWNED er PACIFIC <br /> DRAFT STOP REQUIREMENTS '' x, WALLS AND SUPPORTING MEMBERS --- n RIDGE HCHES.USE OF THIS <br /> �' J FOYER WITH 1/2'G.W.B.t 5/B"TYPE'X'ON FLAN PROHIBITED BY LAW <br /> 26. ENCLOSEC USABLE SPACE UNDER STAIRS TO BE PROTECTED WITH Yz'GWB AT THE b o or a WITHOUT PAYMENT of <br /> - WALLS,UNDER-STAIR SURFACES AND SOFFITS. - LL THE CEILING LICENSE FEE To PAciFK <br /> 27. PROVIDE FIREBLOCKING PER PLAN AND @ ALL PLUMBING PENETRATIONS. "' - a RIDGE HOMES. <br /> 3 --cr x _ ____ _ <br /> 36°KNEE sr 38"H HALF W5 PLAN 5UMMARY <br /> z I: <br /> WALL BELOW xr WALL u+a ae xsee,v.fT., <br /> FOR <br /> n D UTILITY <br /> 3" LAYOUT, <br /> 203 UP UP SEE W5/I1A 814 <br /> PIC �� 3-0 i ,14T - we"l��nfr., <br /> (5G) N 1195 <br /> 2030 15070 GARAGE DOOR <br /> PIC FRO 1'-III 2009 n <br /> LINE OF FLOOR ABOVE cwu��nn_ a r FRONT PORCH Q J PORC 405 <br /> 68 5F - �. 27 5 �GAS <br /> 1 .wane,uv.nne rmm�u <br /> I ' <br /> � I <br /> w <br /> w a i JWA <br /> N IN I BTL ENGINEERING <br /> Q <br /> z Iz I 1�" SEE REVI5ION LOG <br /> I'-6' 7' I'-' '-5' 2'-0' I'-b' 3'-9' I'-b' I'-II° 15'-3"R.O. 2'-4z" wif uxa <br /> 0 <br /> u I SCALE: y'-1'-0' <br /> 0 <br /> 3'-442 <br /> DRIVEWAY ever ravens <br /> 10' WIDTH MAIN FLOOR PLAN <br /> EXTENDED FRONT PORCH <br /> DRl` _- t '/PORCk PLAN OPTION - 'B' ELEV. MAIN FLOOR PLAN - 'B' ELEV. <br /> SCALE: 3/8'=1'-0' SCALE: I/4'=I'-0' <br /> - SCALE: I/4'=I'-0" A4E3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.