My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9502 18TH AVE W H 2023 Plans 2025-02-03
>
Address Records
>
18TH AVE W
>
9502
>
Plans
>
9502 18TH AVE W H 2023 Plans 2025-02-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/3/2025 9:25:21 AM
Creation date
1/27/2025 7:00:21 AM
Metadata
Fields
Template:
Address Document
Street Name
18TH AVE W
Street Number
9502
Unit
H
Permit
B2310-047
Year
2023
Notes
NEW SFR - REF RB2306-001 - Unit H
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ib' <br /> FLOOR PLAN NOTES A <br /> p OF SOAP NICHE,SHOWER PEPLAN <br /> PIX TUBING, �CONTRO t SHOWER PAN -_- <br /> I. CONTRACTOR SHALL VERIFY ALL NOTES,MATERIALS t CONDITIONS PRIOR TO TYP' " <br /> CONSTRUCTION. SHOWER CONTROLS <br /> 116'DEEP <br /> WINDOWS 4 DOORS: 50AP NICHE <br /> 2. ALL EXTERIOR WINDOW 4 DOOR HEADERS TO BE INSULATED w/R-10 INSULATION, BUTT NICHE TILE <br /> 3. WINDOWS 4 DOORS ARE SHOWN t NOTED AS NOMINAL SIZES. INTO FIELD TILE, <br /> 4. WINDOW HEAD HEIGHT R.O.SHOWN PER ELEVATIONS. EGRESS WINDOW SILL HEIGHT R.U.@ TOP t SIDES <br /> ZD <br /> MAX.42'A.F.F. t." BUTT FIELD 24'5. ALL WOOD IN CONTACT WITH CONC,TO BE PRE55URL TREATED. <br /> 6. EXTERIOR WALLS TO BE 26 STUDS @ 16'OC., U.NO. (ZOOMED IN @ NICHE) TILE INTO 30-0' <br /> 7. GARAGE DOOR HEADERS @ 84'A.F.F. BOTTOM OF <br /> 8. EXTERIOR SWING DOOR HEADERS @ 83 1/2"A,F.F. (3)LAYERS I' NICHE TILE 15'-7Y' 14'-411 <br /> 9. INTERIOR SWING DOOR HEADERS @ 83'A.F.F. POLY-I50 RIGID APPROX.STUD _ <br /> 10. SWING DOORS TO FOLLOW CENTERLINE DIMENSION IN PLANS 49 BE 3"MIN.ON HINGE SIDE. INSULATION,EXT. LAYOUT 5-� 6'-0' 4-7" __.,_,-V-2' 2'-0' 4-2Y <br /> II. GARAGE-TO-HOUSE DOOR TO BE A SOLID WOOD lhp THICK 20-MINUTE FIRE-RATED DOOR WALLS ONLY <br /> w/A SELF CLOSING HARDWARE DEVICE. DOUR__ <br /> 12. PER R311.5.1;THE LANDING OR FLOOR ON THE EXTERIOR SIDE OF ALL EXTERIOR DOORS SHOWER <br /> EXCEPT THE FRONT DOOR SHALL BE NOT MORE THAN 7-3/4"BELOW THE TOP OF THE w <br /> THRESHOLD PROVIDED THE DOOR DOES NOT SWING OVER THE LANDING OR FLOOR FIELD TILE-------- 2030 <br /> 13, ALL BI-FOLD t BI-PASS DOORS TO BE CENTERED,U.N.O. `s 4V4" XO _ <br /> FRAMING: suowER PAN 6046 x0(EGRESS) ��5j (S] <br /> 14. VERIFY FIREPLACE STYLE t LOCATION w/SUPERVISOR PRIOR TO CONEY. <br /> 15. FRAMER5 TO INSTALL ALL WINDOWS t INTERIOR COLUMNS SECTION A-A 26 or 2x4 2x8 WALL, SECTION AA=A CPT T <br /> 16. TOWEL RING BLK'G @ 57'A.F.F. (@ EXTERIOR WALL) WALL PER PLAN BACK WALL OF (@ INTERIOR WALL) <br /> 17. TOWEL BAR BLK'G @ 48'A.F.F.4 BLOCK BOTH BAYS. SHOWER,TYP, - � O <br /> I& TOILET PAPER HOLDER BLK'G @ 22'A.F.F.AND 42'FROM BACK WALL WHERE P055113LE QFC SHOWER SOAP N IC I E <br /> 20. 2 ' 2 6" I �" b-b°> - `Lu U <br /> 20 THERMOSTAT BLK'G @ 60' B J O .�; <br /> EXTERIOR LIGHT BLOCKS AT <br /> ALL FRONT ENTR"'S SHALL BE INSTALLED AT T-6"A.F.F. SCALE:NTS @8L <br /> 2L THE TOP OF THE EXTERIOR LIGHT BLOCKS AT GARAGE SHALL ALIGN WITH TOP OF THE 6'6x13'I <br /> 8 T <br /> GARAGE DOUR TRIM I <br /> 22. ADD CONT.BLOCKING FOR STAIR HANDRAIL BRACKETS BEDROOM I LL- <br /> i <br /> 23. STAIRS w/WINDER STEPS WILL ALWAYS HAVE A CONTINUOUS HANDRAIL INSTALLED ON I 30'x80' i �_2" if L� <br /> THE IN51 OF THE STAIR'S RUN DOUBLE RIM OR _ 123XI52, I GWB FIN15HED I-. 4` tl I m < <br /> 24. LADDER-BLOCK AT EXTERIOR WALLS AS NECESSARY FOR INSULATION INSTALL PROVIDE SPLICE ,� OPENINGG I,n TB 5H ER _ <br /> VENTILATION: s <br /> �; 61IOx9'10 ;� � I.2. <br /> 25. WHOLE HOUSE VENTILATION SHALL BE PROVIDED BY-CENTRAL EXHAUST FAN IN <br /> ACCORDANCE WITH 11505.4.11 i 22"x30' m s _ <br /> 26. WHOLE HOUSE FAN SHALL OPERATE CONTINUOUSLY. QSO I r 39�ATTIC 24 HAL <br /> 27. WHOLE HOUSE FAN CFM RATE BASED ON TABLE M150b.4.3(1).EXAMPLE:70 CFM FOR 2600 ACCESS 12°- <br /> �___________� T <br /> SF HOME w/4 BEDROOMS,AND THEN INCREASE BY FACTOR OF 1.5 PER TABLE ADD FLAT MINI-SPLIT W/S(I) T1� - <br /> M1505A.3(2)TO ACCOUNT FOR NOT-BALANCED, NOT-DISTRIBUTED VENTILATION SYSTtil. 2X4 THROUGH <br /> 28. WHOLE HOUSE FAN SHALL BE 1.0$ONES OR LE55.AND SHALL HAVE AN EFFICACY OF 2B JOIST @ 5'O.C. x6" MINI-SPLIT 2xb WALL `--J <br /> CFM/WATT PER BE I R40DUC �," W/5 3UTILITY <br /> 29, FRESH AIR SHALL BE INTRODUCED INTO THE HOUSE VIA OPERABLE WINDOWS PER STA Tt - 5'4XI0'3 <br /> CODE INTERPRETATION 17-15. <br /> 30, PROVIDE A FRESH AIR TRANSFER GRILL ABOVE DOOR HEADER IN THE ROOM WITH THE Y%3✓O° H5 20 BF wH <br /> WHOLE HOUSE FAN. 7-2lx' I <br /> 31. PER IRO M1502.4.5.:WHERE THE DRYER VENT EXHAUST DUCT IS CONCEALED WITHIN THE �868 <br /> BUILDING CONSTRUCTION,THE EQUIVALENT LENGTH OF THE EXHAUST DUCT SHALL BE STT HR5416Z. <br /> IDENTIFIED ON A PERMANENT LABEL OR TAG. THE LABEL OR TAG SHALL BE LOCATED ATTACH 16 SECTION THRU <br /> WITHIN 6FT OF THE EXHAUST DUCT CONNECTION. 2x AND TO WALL CAP LOFT <br /> LIFE SAFETY: 8 <br /> STAIR RIM 13'gx1B'7 3 VANITY TP2 moo° o <br /> 4" <br /> 26. A HEAT ALARM OR HEAT DETECTOR RATED FOR AMBIENT OUTDOOR TEMPERATURES AND � - us TUB <br /> HUMIDITY TO BE CENTRALLY LOCATED IN THE GARAGE. <br /> cPr HALL BATH 5140NEF <br /> 27. THE HEAT ALARM OR HEAT DETECTOR WILL BE CONNECTED TO AN ALARM OR SMOKE 74 5 xlO3 TB <br /> ALARM THAT IS INSTALLED IN THE DWELLING AND LOCATED IN A HALLWAY,ROOM OR Y " 1 <br /> OTHER LOCATION THAT WILL PROVIDE OCCUPANT NOTIFICATION k C W/NEQ <br /> 10, SMOKE DETECTORS TO BE NOV, INTERCONNECTED,w/BATTERY BACKUP d CENTRALLY HALF WALL FRAMING CAP DE-TAIL ®, ---- �A" T <br /> LOCATED IN EACH HABITABLE ROOM. ADDITIONAL SMOKE DETECTORS SHALL BE DI5 SCALE:IYI'=1-0"' `�,' SD/CO b 3'-0' iV 7T <br /> INSTALLED WHERE THERE 15 A CEILING HEIGHT CHANGE GREATER THAN 24 - <br /> 11, SMOKE DETECTORS SHALL BE INSTALLED NOT LE55 THAN 3 FT HORIZONTALLY FROM TOE 15R,14T W, 1-2}' EO 40 !"Il <br /> DOOR OR OPENING OF A BATHROOM THAT CONTAINS TUB OR SHOWER.ER3141 DN _ <br /> 12, IONIZATION SMOKE ALARMS: R 42 N HALF WALL^ O <br /> SO <br /> + ISHALL NOT BE INSTALLED LESS THAN 20 FT HORIZONTALLY FROM A PERMANENTLI' ___________ <br /> INSTALLED COOKING APPLIANCE. -PROVIDE MIN.30' ATTIC ACCESS 3T <br /> + IONIZATION SMOKE ALARMS WITH AN ALARM-51ENCING SWITCH SHALL NOT BE INSTALLED HEADROOM CLEARANCE. SHEATHING ON 3T EO EQ 5D <br /> LESS THAN 10 FT HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING APPLIANCE. -TRUSSES MUST BE OUTSIDE OF 40 BF <br /> 24, PHOTO ELECTRIC SMOKE ALARMS SHALL NOT BE INSTALLED LESS THAN b FT INSTALLED @ 24'O,C. TRUSS MEMBERS ST O COPYRIGHT NOTICE.THIS <br /> HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING APPLIANCE M141 'ddam PLAN IS OWNED BY PACIFIC <br /> 25.GARAGE NOTE:WRAP ALL WARM WALLS AND SUPPORTING MEMBERS WITH 1/2'G.W.B,N 5/8" 'T 3 RIDGE HOMES.USE of THIS <br /> SE 6'-7' 3'-2' V-b' 6'-9° PLAN 15 PROHIBITED BY LAW <br /> TYPE'X'ON THE CEILING.POLY SEAL RIM, ENTIRE GARAGE TO MEET JURISDICTION Q a x OPEN TO --- - ---- _._--- <br /> WITHOUT PAm0M I <br /> - DRAFT STOP REQUIREMENTS m � BELOW - LICENSE FEE TO PACIFIC <br /> 26, ENCLOSED USABLE SPACE UNDER STAIRS TO BE PROTECTED WITH Y°GWB AT THE RIDGE HOMES. <br /> YNALLS,UNDER-STAIR SURFACES AND SOFFITS. <br /> 27, PROVIDE FRE'BLO;KING PER PLAN AND @ ALL PLUMB114G PENETRATIONS. L38'N HALF -_ PLAN SUMMARY <br /> 5/4 LTRIM GWB ATTIC "T WALL d = HOPS uNnaeuewra n. <br /> OR SIM. ACCESS LID <br /> v <br /> In' �n\ATTIC ACCESS DETAIL uT "T BEDROOM 2 BEDROOM 3 -1 <br /> SCALE:112'=I'-0r q'4xl2'9' g14x16'10 Ham'`"� R. <br /> 1195 <br /> mu.f mrT. <br /> GROUT 1 �P 4020 PIC 200q <br /> A. AT <br /> YP. <br /> wwe.ru <br /> SHOWER GLA55 1 5046 XO(EGRESS) W46 XO(EGRESS) 405 <br /> FRAME w/GRID PER ELEV. w/GRID PER ELEV. w"t mcrs• <br /> ILE <br /> AP y' LINE OF WALL BELOW GAS <br /> DRYWALL A JWAILE 12%S.A.M., <br /> BITUTHENEOI EQUIV. BTL ENGINEERING <br /> 7 3 2'-7-' 5LO' V 2'-7Y' 5'-0' 2'-7y4'2x4 STACKED SEE REVISION LOG <br /> BLOCKING AT 3'-2 ' 4'-0' 2'-ql"SHOWER CURB. H 9'-9' ' 'AT HALF SCALE: YA°=I'-0' <br /> WALL,FRAME 10'-0' 20'-0' •m rmem <br /> LIKE HALF <br /> SUB FLOOR WALL. Q 30'-0° UPPER FLOOR PLAN <br /> � TILED SHOWER CURB (HALF WALL SIM.) UPPER FLOOR PLAN - 'A' $ 'B' ELEV <br /> VLV SCALE:3'=I'-0" <br /> SCALE: I/4°=V4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.