Laserfiche WebLink
INTERNAL DACT MOD. <br /> DOOR-DIALER X300 TELCO PATCH <br /> MOUNTING PLATE I tl- <br /> CABLE (LINE 1) <br /> LINE Ring STYLE 4 SLC CIRCUIT <br /> Tip 12 T-TAPPING PERMITTED 5 A (TYP.) <br /> 214DC IN X3011 h' ,_ <br /> TELCO PATCH (LINE 2) <br /> PX LINE SMOKE DETECTORX102 I 2 RingTIP TELEPHONE CABLE t + 1 + 1 + 1 + <br /> TO SLC#1 CIRCUIT DEVICES 2 _COM 2 _COM 2 _COM 2 _COM <br /> BUILDING SPRINKLER SYSTEMS 5 1 3 3 INPUT 3 INPUT 3 INPUT <br /> 5 CH 1 5 CH 1 46 CH 1 <br /> AND ELEVATOR PNL. MONITORING SLC 6 lb HMS-D — — — <br /> INPUT 8 = NOT 8 RELAY 8 <br /> CH #2 USED <br /> D <br /> o ©� TRI-D 6 TRI-S 6 TRI-R 6 <br /> o t 2 3 a 5 s 7 8 o BUSS OUT BUSS IN SMOKE DETECTOR MANUAL STATION D <br /> DLC 1A DLC 1B m`o <br /> I+ -I' TYPICAL-ALL TYPICAL-ALL D <br /> 0 0 BAT.PLUG 24DCPMRR.OUT EOLR EOLR EOLR <br /> Q ¢ ®ti 3.6K 3.6K 3.6K <br /> AD PLUG <br /> USER USER <br /> 9 10 11 1213141516 RLY2 RLY1(SUPV) <br /> I.'--I.'--I MONITORED SWITCHES MONITORED SWITCH MONITORED SWITCH <br /> CC2 CARD CAGE #1 BACK PLANE J NOT USED o 19 OF212223 4W <br /> 0 <br /> mi 24DC OUT EOLR <br /> o - TRBL ALAI INTERNALINPUT++ to�-lo�nI I+ -I E8 3.6K SINGLE a� WITH RELAY <br /> J 1718 19 20 2122 23 24 N 13 14 15 16 17 18m 1 2 <br /> E11/ES(LE EDGE) o - - DUAL INPUT IFD <br /> TYPICAL SLC CIRCUIT WIRING <br /> BUILDING FACP INTERNAL WIRING DIAGRAM SCALE: NONE <br /> SCALE: NONE <br /> ------------------------------------------------------- <br /> l o O o <br /> I—I I—I NOTE: T-TAPPING NOT PERMITTED. CONDUCTORS <br /> �LJ1 �LJ1 MUST GO IN AND OUT OF EACH DEVICE. <br /> SEE PLAN VIEWS <br /> SLOT FOR WIRE SIZE <br /> II + <br /> I TO NAC CIRCUIT — H + + — H + + — S + + EOLR <br /> V + C. <br /> - <br /> o IIIIII 6:8 O 1/1/1 1/1/2 1/1/3 <br /> IIIIII I 10 I <br /> 0 0 R"x°oR <br /> o PSG ,2�"'xAT ro TYPICAL HORN/STROBE CIRCUIT WIRING <br /> O SCALE: NONE <br /> oo.� °o rouie <br /> o "- Oaxru,•u <br /> N <br /> a °NF•"� � <br /> 0 <br /> 5 )°o �o�ss ADDR. <br /> ;oo."-" <br /> I <br /> FDC10422 FDC10422 <br /> DLC DO NOT USE +1B A DO NOT USE +1B A <br /> DO NOT USE +1B A RELAY (NOT USED) DO NOT USE +1B A RELAY (NOT USED) <br /> SLC IN - 6 B SLC IN - 6 B <br /> SLC OUT - 6 g RELAY (NOT USED) SLC OUT - 6 g RELAY (NOT USED) <br /> ADDR. SLC IN + 5 SLC IN + 5 <br /> 000 SLC OUT + 5 C SLC OUT + 5 C <br /> - RELAY NOT USED RELAY NOT USED <br /> I <br /> C ( ) C ( ) <br /> �• �6 ELEV FA 1 D RELAY (NOT USED) PRESSURE D RELAY (NOT USED) <br /> 0 6o xo, <br /> O ❑ 1 D p <br /> 2 2 <br /> o O .SLIP • ELEV TRBL 2 ISO TAMPER 2 <br /> i ;�... ••I'�I-I �•i i ELEV SUP 3 TAMPER 3 <br /> I <br /> 4 4 <br /> 4 4 <br /> I <br /> I o o O o ® O <br /> j TYPICAL ELEV PNL MONITORING TYPICAL SPRINKLER MONITORING <br /> n EOM u I o SCALE: NONE SCALE: NONE <br /> CAUDON HIGH VOLTAGE <br /> n <br /> IIIIII I as��r P,d o�`� � I <br /> MI <br /> IIIIII O O OOL <br /> I E__> <br /> o I I TO 120 VAC DEDICATED CKT. <br /> II I ON EMERGENCY POWER <br /> I G------------------------------------------------------------------------1 Timothy C.Eastman-2553&- qg C' <br /> NICET C <br /> BUILDING FACP INTERNAL CARD AND PANEL LAYOUT EE:rtlticaliD _Level lMaTGhl01,2025 <br /> PO BOX 1138 <br /> SCALE: NONE TF� AUBURN.WA 98071 <br /> SEAIRONICS 253-939-6060 <br /> FIRE PROTECTON SERVICES.qB N0. DwG x0. <br /> 8401445 8401445-E506-6 0 <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE AWN A SUBTITLE CURRENT REVISION SYMBOL DATE <br /> ACCEPTABILITY CHECKED 0B.,2.z4 FIRE ALARM SYSTEM DETAILS A 08.12.24 <br /> A EVERETT FIRE PANEL REPLACEMENT- RECORD SEA SEA 01.25.19 Sp THIS DESIGN AND/OR <br /> B 40-36 FSI SEA SEA 08.12.24 APPROVEDECIFIC <br /> IS DDEP. I DATE SEA 08.12.24 SHEET SEQUENCE No. <br /> N IN E <br /> BOE//VG 40-36 FS' E506-6 6 <br /> y CHECKED � <br /> APPROVED BUILDING 40-036 JOB N0. <br /> j APPROVED ELECTRICAL MASTER 08.12.24 DWG No. 40-035-E506-6 <br /> WAS 40-35-E513 <br />