My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3433 TULALIP AVE 2025-03-28
>
Address Records
>
TULALIP AVE
>
3433
>
3433 TULALIP AVE 2025-03-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/28/2025 7:42:14 AM
Creation date
1/27/2025 3:58:58 PM
Metadata
Fields
Template:
Address Document
Street Name
TULALIP AVE
Street Number
3433
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MODULE SPECIFICATIONS MICROINVERTER SPECIFICATIONS CONTRACTOR INFORMATION <br /> REC SOLAR REC420AA PURE SUNERGYsYSTEMs <br /> MODEL 2-BLK (420W) MODEL ENPHASE IQ8M-72-M-US (240V) � <br /> Employee Owned <br /> MODULE POWER @ STC 420W POWER RATING 325W <br /> OPEN CIRCUIT VOLTAGE:Voc 49.1V SUNERGY SYSTEMS <br /> MAX POWER VOLTAGE:Vmp 42.2V MAX OUTPUT CURRENT 1.35A ADDRESS: 4546 LEARY WAY <br /> SHORT CIRCUIT CURRENT:Isc 10.74A <br /> CEC WEIGHTED EFFICIENCY 97.5% NORTHWEST, SEATTLE, WA 98107 <br /> MAX POWER CURRENT:Imp 9.96A MAX NO OF MICRO <br /> PHONE NUMBER: (206) 297-0086 <br /> INVERTERS/BRANCH 11 (EXTERIOR) LICENSE NUMBER: SUNERSI905D4 <br /> TEMPERATURE COEFFICIENT:Voc -0.24%/°C <br /> (E)120/240V 1PH 60HZ LICENSE TYPE: ELECTRICAL <br /> MODULE DIMENSIONS: L x W x H 73.4" x 40.9"x 1.2" MAX DC VOLTAGE 60V METER:SNOHOMISH <br /> COUNTY PUD NO 1 <br /> NOTE: 127008 UTILITY <br /> 1. MICROINVERTERS ARE RAPID SHUTDOWN COMPLIANT AS PER NEC 690.12. (�) GRID CUSTOMER INFORMATION <br /> 2. INSULATED PIERCING TAPS USED FOR THE LINE SIDE TAP SHALL BE LISTED AND MARKED SUITABLE FOR USE ON THE LINE SIDE OF THE (INTERIOR) <br /> MAIN SERVICE PANEL IN ACCORDANCE WITH NEC 230.46. CTCABINET NAME: DANIEL GOODMAN <br /> ADDRESS: 3433 TULALIP AVENUE, <br /> EVERETT, WA 98201 <br /> (ROOF EQUIPMENT) I (GROUND LEVEL EQUIPMENT) COORDINATES: 47.971262, -122.219688 <br /> (N)CONSUMPTION CTS (INTERIOR) 7(INTERIOR) APN: 00437783001602 <br /> (N)(35)REC SOLAR AA PURE 2-BLK(420W)MODULE WITH <br /> (N)(35)ENPHASE IQSM-72-M-72-M-US(240V)MICROINVERTER (E)200A END FED (E)200A END FED <br /> (1)BRANCH OF(9)MICROINVERTER MAIN SERVICE PANEL MAIN SERVICE PANEL <br /> (1)BRANCH OF(9)MICROINVERTER I z z <br /> (1)BRANCH OF(9)MICROINVERTER 47aac/240vac (N)LINE SIDE TAP 14.700kW DC/ 11.375kW AC ROOF <br /> (1)BRANCH OF(8)MICROINVERTER (EXTERIOR) PER NEC 705.11 <br /> LINE (EXTERIOR) � N W � N W MOUNT PV SYSTEM <br /> (N)ENPHASE IQ (EXTERIOR) (INTERIOR) w m a m <br /> COMBINER 4 (N)PV PRODUCTION <br /> - (N)JUNCTION I L (N)60A AC METER N)125A BREAKER <br /> BOX DISCONNECT ENCLOSURE <br /> 15A 2P <br /> 1 2 20A/2P 3 3 M 3 <br /> BR <br /> 20A/2P <br /> 20A/2P 2P <br /> BREAK <br /> ER 7 <br /> NEMA 4X RATED 20A/2P EATON DG222URB LOAD EA IN L BR241125SP (E)GROUNDING (E)GROUNDING <br /> LOAD C <br /> JUNCTION BOX ENPHASE IQ COMBINER AC DISCONNECT MAIN LUG ELECTRODE ELECTRODE <br /> PV PRODUCTION ENTER TYPE - - <br /> WTH IQ GATEWAY NON FUSED 60A, METER 120/240V, AC DISCONNECT <br /> (N)ENPHASE IQ8M-72-M-US(240V) = _ <br /> MICROINVERTER PER MODULE X-IQ-AM1-240-4, 120/240V,2P,BREAK- NEMA 3R 125A,120/240V,2P, <br /> 120/240V,NEMA 3R, VISIBLE,LOCKABLE, LOCKABLE,LOAD (INTERIOR) <br /> INSTALL LOAD BREAK RATED, Customer Owned <br /> (4)20A 2P PV BREAKER ACCESSIBLE 24/7, BREAK RATED, (E)200A SUB PANEL <br /> (1)15A 2P GATEWAY NEMA 3R VISIBLE, <br /> BREAKER(ONLY FOR ACCESSIBLE 24/7 z¢ <br /> SOLAR,NO LOADS <br /> TO BE ADDED) (N)EV CHARGER l ¢w <br /> (INTERIOR) <br /> w <br /> wq� <br /> in <br /> L__cR__F <br /> CONDUCTOR SCHEDULE <br /> TAG ID CONDUIT SIZE CONDUCTOR NEUTRAL GROUND (N)60A2P <br /> EV BREAKER <br /> 1 NONE (2) 12 AWG ENPHASE Q CABLE NONE (1) 6 AWG BARE COPPER, EGC <br /> PER BRANCH CIRCUIT PROJECT ID AUR-1004630 <br /> 2 3/4" EMT (8) 10 AWG THHN/THWN-2, Cu NONE (1) 10 AWG THHN/THWN-2, EGC DATE 9/27/2024 <br /> 3 3/4" EMT (2) 6 AWG THHN/THWN-2, Cu (1)8 AWG THHN/THWN-2, Cu (1) 10 AWG THHN/THWN-2, EGC <br /> CREATED BY VK <br /> 4 3/4" PVC (2) 6 AWG THHN/THWN-2, Cu (1) 8 AWG THHN/THWN-2, Cu NONE <br /> 5 3/4" EMT (2) 12 AWG THHN/THWN-2, Cu NONE SIGNATURE <br /> 6 3/4" EMT (2) 6 AWG THHN/THWN-2, Cu (1)6 AWG THHN/THWN-2, Cu (1) 10 AWG THHN/THWN-2, EGC SINGLE LINE DIAGRAM <br /> PV-4 <br /> 7 NONE (1) 6 AWG BARE COPPER, GEC <br /> E EXISTING <br />
The URL can be used to link to this page
Your browser does not support the video tag.