Laserfiche WebLink
STRUCTURAL NOTES CONTRACTOR INFORMATION <br /> 1. ALL SOLAR PANEL COMPONENTS SHALL BE INSTALLED PER (E) COMPOSITION SHINGLE ROOF <br /> THE MANUFACTURER'S APPROVED INSTALLATION MEMBRANE <br /> SPECIFICATIONS. (N) SUNMODO EZ-MOUNT ROOF KIT WITH SUNERGUYST MS <br /> 2. THE EXISTING BUILDING'S STRUCTURE SHALL BE VERIFIED AS L-FOOT AND 2" STANDOFF Employee Owned \� <br /> PROPERLY CONSTRUCTED AND MAINTAINED IN GOOD <br /> CONDITION. NO ALLOWANCE HAS BEEN MADE FOR ANY (N) SUNMODO SMR100 RAIL SUNERGY SYSTEMS <br /> EXISTING DEFICIENCY IN DESIGN, MATERIAL, <br /> CONSTRUCTION, OR LACK OF MAINTENANCE FOR THE ADDRESS: 4546 LEARY WAY <br /> EXISTING STRUCTURE OR PROPOSED EQUIPMENT. NORTHWEST, SEATTLE, WA 98107 <br /> CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS, (N) SOLAR MODULE <br /> PROPER FIT, AND CLEARANCES IN THE FIELD. PHONE NUMBER: (206) 297-0086 <br /> 3. IF ANY CONDITION THROUGHOUT THE ASSOCIATED REPORT LICENSE NUMBER: SUNERSI905D4 <br /> OR PERMIT DRAWINGS IS NOT REPRESENTED ON-SITE, LICENSE TYPE: ELECTRICAL <br /> CONTRACTOR SHALL NOTIFY THE ENGINEER OF RECORD <br /> (EOR) OF ANY DISCREPANCIES AND RECEIVE WRITTEN <br /> APPROVAL FROM THE FOR BEFORE PROCEEDING WITH CUSTOMER INFORMATION <br /> INSTALLATION. 6" MAX <br /> 4. MISCELLANEOUS ITEMS NOT EXPLICITLY NAMED & SHOWN IN NAME: DANIEL GOODMAN <br /> THESE DRAWINGS HAVE NOT BEEN DESIGNED. IT IS <br /> RECOMMENDED THAT MATERIAL OF SUITABLE SIZE & ADDRESS: 3433 TULALIP AVENUE, <br /> STRENGTH BE OBTAINED FROM A REPUTABLE EVERETT, WA 98201 <br /> MANUFACTURER FOR MISCELLANEOUS ITEMS. <br /> 5. CONTRACTOR SHALL BE RESPONSIBLE TO COMPLETE, SEAL, (E) 2" X 4" TOP CHORD COORDINATES: 47.971262, -122.219688 <br /> &WATERPROOF ROOFTOP PENETRATIONS FOR SOLAR @ 24" O.C. SPACING APN: 00437783001602 <br /> RACKING. <br /> 6. CONTRACTOR TO PROVIDE MINIMUM 1/4" GAP BETWEEN ALL <br /> SOLAR PANELS. 14.700kW DC / 11.375kW AC ROOF <br /> 7. PROJECT WINDSPEED IS BASIC WIND SPEED PER CODE MOUNT PV SYSTEM <br /> UNLESS NOTED OTHERWISE. <br /> (E) ROOF DECKING <br /> - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - <br /> DEAD LOAD CALCULATIONS <br /> BOM QUANTITY LBS/UNIT TOTAL <br /> WEIGHT (LBS) I <br /> MODULES 35 47.8 1673 <br /> I I <br /> MID-CLAMP 48 0.14 6.72 I <br /> END-CLAMP 44 0.24 10.56 I <br /> RAIL LENGTH 252 0.41 103.32 - I <br /> I <br /> SPLICE BAR 6 0.56 3.36 I <br /> PROJECT ID AUR-1004630 <br /> SUNMODO EZ ROOF L - - - - - - - - <br /> MOUNT KIT WITH DATE 9/27/2024 <br /> L-FOOT (DECK 81 1.12 90.72 SCALE: NTS <br /> MOUNT) CREATED BY VK <br /> MICROINVERTER 35 2.43 85.05 (N) SUNMODO EZ-MOUNT ROOF KIT <br /> WITH L-FOOT AND 2" STANDOFF SIGNATURE <br /> TOTAL WEIGHT OF THE SYSTEM (LBS) 1972.73 (N) STAINLESS STEEL 5/16" LAG BOLT MIN. 2.5" <br /> STRUCTURAL DETAILS <br /> TOTAL ARRAY AREA ON THE ROOF (SQ. FT.) 729.66 EMBEDMENT PILOT HOLE REQUIRED <br /> WEIGHT PER SQ. FT.(LBS) 2.7 (E) 2" X 4"TOP CHORD @ 24" PV-3.2 <br /> O.C. SPACING <br /> WEIGHT PER PENETRATION (LBS) 24.35 <br />