My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2916 47TH ST SE 2025-03-03
>
Address Records
>
47TH ST SE
>
2916
>
2916 47TH ST SE 2025-03-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 8:11:11 AM
Creation date
1/28/2025 7:57:09 AM
Metadata
Fields
Template:
Address Document
Street Name
47TH ST SE
Street Number
2916
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Product Specifications Bosch IDS BOVB 18113 <br /> 4.2 BOVB 18+BVA 2.0 <br /> (30VB36-18+BVA2.024 <br /> TC 17.7 18.0 18.5 18.7 18.4 18.6 18.8 19.1 19.6 19.8 20.1 20.3 / 25.7 25.9 26.2 <br /> 65 S/T 0.90 0.95 0.99 1.00 0.64 0.84 0.95 0.96 0.39 0.57 0.74 0.92 / 0.38 0.53 0.69 <br /> kW 0.90 0.91 0.92 0.92 0.92 0.93 0.94 0.95 0.94 0.95 0.96 0.97 / 1.21 1.22 1.24 <br /> Tc 17.9 18.2 18.6 18.8 18.5 18.8 19.0 19.4 19.8 20.1 20.3 20.5 / 25.3 25.6 25.8 <br /> 75 S/T 0.90 0.95 0.99 1.00 0.64 0.84 0.95 0.96 0.39 0.57 0.74 0.92 / 0.38 0.53 0.69 <br /> kW 1.07 1.08 1.09 1.09 1.09 1.10 1.11 1.12 1.12 1.13 1.14 1.15 / 1.47 1.49 1.50 <br /> TC 17.9 18.2 MA 18.8 18.5 18.8 19.0 19.3 19.7 20.0 20.2 20.4 / 25.3 25.5 25.8 <br /> 85 S/T 0.90 0.95 0.99 1.00 0.64 0.84 0.95 0.96 0.39 0.57 0.74 0.92 / 0.38 0.53 0.69 <br /> 620 kW 1.27 1.28 1.29 1.29 1.29 1.31 1.32 1.33 1.33 1.34 1.35 1.36 / 1.64 1.66 1.67 <br /> TC 17.8 18.1 18.6 18.8 18.5 18.8 19.0 19.3 19.7 20.0 20.2 20.4 ( 25.2 25.4 25.7 <br /> 95 S/T 0.90 0.95 0.99 1.00 0.64 0.84 0.95 0.96 0.39 0.57 0.74 0.92 / 0.38 0.53 0.69 <br /> kW 1.53 1.54 1.56 1.56 1.56 1.57 1.59 1.60 1.61 1.62 1.63 1.64 / 1.96 1.98 2.00 <br /> TC 17.8 18.0 18.5 18.7 18.4 18.7 18.9 19.2 19.6 19.9 20.1 20.3 / 24.8 25.0 25.2 <br /> 105 S/T 0.91 0.96 1.00 1.00 0.65 0.85 0.96 0.96 0.40 0.58 0.75 0.93 / 0.39 0.54 0.70 <br /> kW 1.79 1.81 1.83 1.83 1.83 1.84 1.86 1.88 1.88 1.90 1.91 1.93 / 2.31 2.33 2.35 <br /> TC 17.5 17.8 18.2 18.4 18.1 18.4 18.6 18.9 19.3 19.6 19.8 20.0 / 24.6 24.8 25.0 <br /> 115 S/T 0.93 0.98 1.00 1.00 0.67 0.87 0.98 0.97 0.42 0.60 0.77 0.95 / 0.41 0.56 0.72 <br /> kW 2.07 2.09 2.11 2.11 2.11 2.13 2.15 2.17 2.17 2.19 2.21 2.23 / 2.71 2.73 2.75 <br /> TC 18.1 18.3 18.8 19.0 18.6 18.9 19.1 19.4 19.8 20.1 20.3 20.6 / 26.1 26.3 26.7 <br /> 65 S/T 0.91 0.96 0.99 1.00 0.65 0.85 0.96 0.97 0.40 0.58 0.75 0.93 / 0.39 0.54 0.70 <br /> kW 0.92 0.92 0.93 0.93 0.93 0.94 0.95 0.96 0.95 0.96 0.97 0.98 / 1.22 1.23 1.25 <br /> TC 18.2 18.5 18.9 19.1 18.8 19.1 19.3 19.6 20.0 20.3 20.5 20.8 / 25.7 26.0 26.3 <br /> 75 S/T 0.91 0.96 0.99 1.00 0.65 0.85 0.96 0.97 0.40 0.58 0.75 0.93 / 0.39 0.54 0.70 <br /> kW 1.08 1.09 1.10 1.10 1.10 1.11 1.12 1.13 1.13 1.14 1.15 1.16 / 1.48 1.50 1.52 <br /> TC 18.2 18.5 18.9 19.1 18.8 19.1 19.3 19.6 20.0 20.3 20.5 20.8 / 25.7 25.9 26.3 <br /> 85 S/T 0.91 0.96 0.99 1.00 0.65 0.85 0.96 0.97 0.40 0.58 0.75 0.93 / 0.39 0.54 0.70 <br /> 660 kW 1.28 1.29 1.31 1.31 1.31 1.32 1.33 1.34 1.34 1.35 1.36 1.37 / 1.65 1.66 1.68 <br /> (Low Stage) TC 18.1 18.4 18.8 19.0 18.7 19.0 19.2 19.5 19.9 20.3 20.4 20.8 / 25.6 25.8 26.1 <br /> 95 S/T 0.91 0.96 0.99 1.00 0.65 0.85 0.96 0.97 0.40 0.58 0.75 0.93 / 0.39 0.54 0.70 <br /> kW 1.53 1.55 1.56 1.56 1.56 1.58 1.59 1.60 1.61 1.62 1.63 1.65 / 1.99 2.00 2.02 <br /> TC 18.0 18.3 18.7 18.9 18.6 18.9 19.1 19.4 19.9 20.2 20.4 20.7 / 25.3 25.6 25.9 <br /> 105 S/T 0.92 0.97 1.00 1.00 0.66 0.86 0.97 0.98 0.41 0.59 0.76 0.94 / 0.40 0.55 0.71 <br /> kW 1.81 1.82 1.84 1.84 1.83 1.85 1.87 1.88 1.89 1.90 1.92 1.93 / 2.34 2.36 2.38 <br /> Tc 17.7 18.0 18.4 18.6 18.3 18.6 18.8 19.1 19.6 19.9 20.0 20.3 / 25.1 25.3 25.7 <br /> 115 S/T 0.94 0.99 1.00 1.00 0.68 0.88 0.99 1.00 0.43 0.61 0.78 0.96 / 0.42 0.57 0.73 <br /> kW 2.08 2.10 2.12 2.12 2.12 2.14 2.16 2.18 2.18 2.20 2.22 2.24 / 2.75 2.77 2.79 <br /> TC 19.9 20.2 20.7 20.9 20.6 20.9 21.1 21.4 22.0 22.3 22.5 22.9 / 28.5 28.8 29.1 <br /> 65 S/T 0.92 0.97 0.99 1.00 0.67 0.87 0.98 0.99 0.42 0.60 0.77 0.95 / 0.40 0.55 0.71 <br /> kW 1.03 1.04 1.05 1.05 1.05 1.06 1.07 1.08 1.07 1.08 1.09 1.11 / 1.37 1.38 1.39 <br /> TC 20.1 20.4 20.9 21.1 20.7 21.1 21.3 21.6 22.2 22.5 22.7 22.9 / 28.6 28.9 29.1 <br /> 75 S/T 0.92 0.97 0.99 1.00 0.67 0.87 0.98 0.99 0.42 0.60 0.77 0.95 / 0.40 0.55 0.71 <br /> kW 1.23 1.24 1.25 1.25 1.25 1.27 1.28 1.29 1.29 1.30 1.31 1.33 / 1.62 1.64 1.66 <br /> TC 20.1 20.4 20.9 21.1 20.7 21.1 21.3 21.6 22.1 22.5 22.7 22.9 / 28.3 28.5 28.8 <br /> 85 S/T 0.92 0.97 0.99 1.00 0.67 0.88 0.98 1.00 0.42 0.60 0.77 0.95 / 0.40 0.55 0.71 <br /> 760 kW 1.42 1.43 1.44 1.44 1.44 1.46 1.47 1.48 1.49 1.50 1.51 1.52 / 1.83 1.84 1.86 <br /> TC 20.0 20.3 20.8 21.0 20.7 21.0 21.2 21.5 22.0 22.4 22.6 22.7 / 28.0 28.3 28.5 <br /> 95 S/T 0.92 0.97 0.99 1.00 0.67 0.88 0.98 1.00 0.42 0.60 0.77 0.95 / 0.40 0.55 0.71 <br /> kW 1.69 1.71 1.72 1.72 1.72 1.74 1.75 1.77 1.78 1.79 1.80 1.81 / 2.20 2.22 2.23 <br /> TC 19.6 19.9 20.3 20.5 20.4 20.6 20.8 21.1 21.8 22.0 22.2 22.4 / 27.0 27.3 27.5 <br /> 105 S/T 0.93 0.98 1.00 1.00 0.68 0.89 0.99 1.00 0.43 0.61 0.78 0.96 / 0.41 0.56 0.72 <br /> kW 1.97 1.99 2.01 2.01 2.01 2.03 2.04 2.06 2.07 2.09 2.10 2.12 / 2.60 2.62 2.63 <br /> TC 19.5 19.7 20.2 20.4 20.4 20.5 20.7 20.9 21.6 21.8 22.0 22.3 / 26.3 26.5 26.8 <br /> 115 S/T 0.95 1.00 1.00 1.00 0.70 0.91 1.00 1.00 0.45 0.63 0.80 0.98 / 0.43 0.58 0.74 <br /> kW 2.37 2.39 2.41 2.42 2.41 2.46 2.48 2.50 2.51 2.53 2.55 2.57 / 3.06 3.08 3.11 <br /> TC 22.1 22.4 22.9 23.2 22.8 23.1 23.3 23.6 24.4 24.6 24.8 25.1 / 30.8 31.1 MA <br /> 65 S/T 0.93 0.98 1.00 1.00 0.68 0.88 0.99 1.00 0.43 0.61 0.77 0.95 / 0.41 0.55 0.71 <br /> kW 1.18 1.19 1.20 1.20 1.20 1.21 1.23 1.24 1.23 1.25 1.26 1.27 / 1.64 1.66 1.68 <br /> TC 21.8 22.2 22.7 22.9 22.6 22.8 23.1 23.3 24.2 24.5 24.6 24.6 / 30.8 31.1 31.4 <br /> 75 S/T 0.93 0.98 1.00 1.00 0.68 0.88 0.99 1.00 0.43 0.61 0.77 0.96 / 0.41 0.55 0.71 <br /> kW 1.38 1.40 1.41 1.41 1.41 1.42 1.44 1.45 1.46 1.47 1.48 1.48 / 1.83 1.85 1.87 <br /> TC 21.7 22.0 22.5 22.8 22.4 22.8 23.0 23.3 24.2 24.3 24.5 24.6 / 30.5 30.8 31.0 <br /> 85 S/T 0.93 0.98 1.00 1.00 0.68 0.89 0.99 1.00 0.43 0.61 0.77 0.96 / 0.41 0.55 0.71 <br /> 860 kW 1.54 1.56 1.57 1.57 1.57 1.59 1.60 1.62 1.64 1.64 1.64 1.66 / 2.01 2.03 2.05 <br /> (High Stage) TC 21.5 21.9 22.4 22.5 22.3 22.6 22.8 23.2 23.8 24.0 24.3 24.5 / 30.3 30.5 30.7 <br /> 95 S/T 0.93 0.98 1.00 1.00 0.68 0.89 0.99 1.00 0.43 0.61 0.77 0.96 / 0.41 0.55 0.71 <br /> kW 1.77 1.79 1.81 1.81 1.81 1.83 1.84 1.86 1.88 1.89 1.89 1.90 / 2.42 2.43 2.44 <br /> TC 20.2 20.5 20.8 21.1 22.0 22.3 22.6 22.9 23.3 23.5 23.7 24.0 / 28.2 28.4 28.6 <br /> 105 S/T 0.94 0.99 1.00 1.00 0.69 0.90 1.00 1.00 0.44 0.62 0.78 0.97 / 0.42 0.56 0.72 <br /> kW 2.09 2.11 2.13 2.13 2.13 2.15 2.17 2.19 2.20 2.22 2.23 2.25 / 2.73 2.75 2.78 <br /> Tc 19.9 20.2 20.5 20.8 21.7 22.0 22.3 22.6 23.0 23.2 23.4 23.7 / 27.9 28.1 28.3 <br /> 115 S/T 0.96 1.00 1.00 1.00 0.71 0.92 1.00 1.00 0.46 0.64 0.80 0.99 / 0.44 0.58 0.74 <br /> kW 2.41 2.43 2.44 2.46 2.46 2.48 2.53 2.55 2.57 2.59 2.61 2.63 / 3.13 3.14 3.15 <br /> TC 25.7 26.0 26.6 26.9 26.6 26.9 27.2 27.5 28.4 28.6 28.9 29.2 / 35.8 36.1 36.3 <br /> 65 S/T 0.95 0.99 1.00 1.00 0.69 0.89 1.00 1.00 0.44 0.62 0.79 0.97 / 0.42 0.55 0.71 <br /> kW 1.51 1.52 1.54 1.54 1.54 1.55 1.57 1.58 1.58 1.59 1.61 1.62 / 2.08 2.11 2.13 <br /> Tc 25.6 25.9 26.5 26.8 26.5 26.8 27.1 27.4 28.3 28.6 28.8 29.1 / 35.1 35.4 35.7 <br /> 75 S/T 0.95 0.99 1.00 1.00 0.69 0.89 1.00 1.00 0.44 0.62 0.79 0.98 / 0.42 0.55 0.71 <br /> kW 1.74 1.75 1.77 1.77 1.77 1.79 1.80 1.82 1.82 1.84 1.86 1.87 / 2.25 2.28 2.30 <br /> TC 25.3 25.6 26.2 26.5 26.2 26.5 26.8 27.1 28.0 28.4 28.6 28.8 / 34.5 34.8 35.1 <br /> 85 S/T 0.95 0.99 1.00 1.00 0.69 0.90 1.00 1.00 0.44 0.62 0.80 0.98 / 0.42 0.55 0.71 <br /> 1080 kW 1.89 1.91 1.93 1.93 1.93 1.94 1.96 1.98 1.99 2.01 2.02 2.03 / 2.49 2.51 2.54 <br /> TC 25.0 25.3 25.9 26.2 25.9 26.2 26.5 26.7 27.7 27.9 28.2 28.4 / 33.2 33.3 33.4 <br /> 95 S/T 0.95 0.99 1.00 1.00 0.69 0.90 1.00 1.00 0.44 0.62 0.80 0.98 / 0.42 0.56 0.73 <br /> kW 2.21 2.23 2.25 2.25 2.25 2.27 2.30 2.32 2.33 2.34 2.36 2.38 / 2.86 2.87 2.88 <br /> TC 24.5 24.8 25.4 25.7 25.4 25.7 25.9 26.2 27.2 27.4 27.6 27.9 / 31.2 31.4 31.5 <br /> 105 S/T 0.96 1.00 1.00 1.00 0.70 0.91 1.00 1.00 0.45 0.63 0.82 1.00 / 0.43 0.57 0.75 <br /> kW 2.57 2.60 2.62 2.62 2.62 2.65 2.68 2.70 2.71 2.73 2.75 2.77 / 3.11 3.11 3.11 <br /> TC 23.9 24.2 24.8 25.0 24.8 25.0 25.3 25.6 26.2 26.4 26.7 26.9 / 28.7 28.8 29.0 <br /> 115 S/T 0.97 1.00 1.00 1.00 0.72 0.93 1.00 1.00 0.47 0.65 0.84 1.00 / 0.46 0.60 0.78 <br /> kW 2.93 2.96 2.99 2.99 2.99 3.02 3.05 3.08 3.09 3.11 3.15 3.17 3.21 3.21 3.22 <br /> Table 10 <br /> TC refer to total capacity SIT.refer to the ratio of sensible heat and total capacity M refer to total input power <br /> Bosch Thermotechnology Corp. 12.2020 Data subject to change <br />
The URL can be used to link to this page
Your browser does not support the video tag.