Laserfiche WebLink
14 Bosch IDSBOVB 18 Product <br /> :r : BVA2.036 <br /> TC 22.1 22.4 23.0 23.3 22.8 23.2 23.4 23.8 24.3 24.5 24.7 25.0 1 29.9 30.2 30.5 <br /> 65 SIT 0.85 0.92 0.96 1.00 0.60 0.83 0.92 0.95 0.39 0.56 0.75 0.88 1 0.39 0.53 0.69 <br /> kW 1.06 1.07 1.09 1.10 1.09 1.10 1.11 1.12 1.11 1.12 1.14 1.15 1 1.45 1.46 1.47 <br /> Tc 21.8 22.1 22.7 23.0 22.5 22.9 23.1 23.5 23.8 24.2 24.6 25.0 1 29.9 30.2 30.5 <br /> 75 SIT 0.85 0.92 0.96 1.00 0.60 0.83 0.92 0.95 0.39 0.56 0.75 0.88 1 0.39 0.53 0.69 <br /> kW 1.60 1.61 1.63 1.64 1.63 1.64 1.65 1.67 1.67 1.68 1.69 1.71 1 1.99 2.00 2.02 <br /> TC 21.7 22.1 22.7 22.9 22.5 22.7 23.1 23.4 23.8 24.1 24.6 25.0 1 29.7 29.9 30.2 <br /> 85 SIT 0.85 0.92 0.96 1.00 0.60 0.83 0.92 0.95 0.39 0.56 0.75 0.88 1 0.39 0.53 0.69 <br /> 650 kW 1.74 1.76 1.77 1.78 1.77 1.78 1.80 1.81 1.82 1.83 1.84 1.85 1 2.15 2.17 2.18 <br /> Tc 21.6 22.0 22.5 22.8 22.3 22.6 22.9 23.3 23.7 24.0 24.4 24.8 1 29.3 29.6 29.9 <br /> 95 SIT 0.85 0.92 0.96 1.00 0.60 0.83 0.92 0.95 0.39 0.56 0.75 0.88 1 0.39 0.53 0.69 <br /> kW 1.82 1.84 1.85 1.86 1.85 1.87 1.89 1.90 1.92 1.92 1.94 1.95 1 2.32 2.34 2.37 <br /> TC 21.4 21.8 22.4 22.6 22.2 22.5 22.8 23.1 23.6 23.8 24.2 24.7 1 29.0 29.2 29.5 <br /> 105 SIT 0.85 0.92 0.96 1.00 0.60 0.83 0.92 0.95 0.39 0.56 0.75 0.88 1 0.39 0.53 0.69 <br /> kW 2.14 2.16 2.18 2.19 2.18 2.20 2.22 2.24 2.26 2.26 2.28 2.30 1 2.77 2.79 2.82 <br /> Tc 21.2 21.6 22.2 22.4 22.0 22.3 22.6 22.9 23.4 23.6 24.0 24.4 1 25.9 26.1 26.4 <br /> 115 SIT 0.86 0.93 0.97 1.00 0.61 0.84 0.93 0.96 0.40 0.57 0.76 0.89 1 0.40 0.54 0.70 <br /> kW 2.50 2.53 2.55 2.56 2.55 2.58 2.60 2.63 2.64 2.66 2.68 2.70 1 3.07 3.08 3.08 <br /> Tc 24.4 24.8 25.4 25.7 25.2 25.6 25.9 26.3 26.9 27.1 27.6 28.0 1 32.8 33.3 33.8 <br /> 65 SIT 0.86 0.93 0.97 1.00 0.61 0.84 0.93 0.96 0.39 0.57 0.76 0.88 1 0.39 0.54 0.70 <br /> kW 1.24 1.25 1.27 1.28 1.27 1.28 1.29 1.30 1.30 1.31 1.33 1.34 1 1.71 1.72 1.75 <br /> Tc 24.2 24.6 25.3 25.5 25.1 25.4 25.7 26.1 26.6 26.9 27.4 27.8 1 32.8 33.3 33.8 <br /> 75 SIT 0.86 0.93 0.97 1.00 0.61 0.84 0.93 0.96 0.39 0.57 0.76 0.88 1 0.39 0.54 0.70 <br /> kW 1.83 1.84 1.86 1.87 1.86 1.87 1.89 1.90 1.91 1.91 1.93 1.95 1 2.18 2.20 2.23 <br /> TC 24.2 24.6 25.2 25.5 25.0 25.3 25.7 26.0 26.6 26.9 27.3 27.8 1 32.8 33.1 33.3 <br /> 85 SIT 0.86 0.93 0.97 1.00 0.61 0.84 0.93 0.96 0.39 0.57 0.76 0.88 1 0.39 0.54 0.70 <br /> 820 kW 1.93 1.95 1.96 1.97 1.96 1.98 2.00 2.01 2.03 2.03 2.04 2.05 1 2.42 2.44 2.46 <br /> (Low Stage) Tc 24.0 24.4 25.0 25.3 24.8 25.1 25.5 25.8 26.3 26.7 27.1 27.5 1 32.3 32.6 32.8 <br /> 95 SIT 0.86 0.93 0.97 1.00 0.61 0.84 0.93 0.96 0.39 0.57 0.76 0.88 1 0.39 0.54 0.70 <br /> kW 2.04 2.06 2.08 2.09 2.08 2.10 2.12 2.14 2.15 2.16 2.18 2.19 1 2.65 2.67 2.69 <br /> TC 23.7 24.1 24.7 25.0 24.5 24.9 25.2 25.6 26.2 26.4 26.8 27.2 1 31.8 32.0 32.2 <br /> 105 SIT 0.86 0.93 0.97 1.00 0.61 0.84 0.93 0.96 0.39 0.57 0.76 0.88 1 0.39 0.54 0.70 <br /> kW 2.39 2.42 2.44 2.45 2.44 2.46 2.49 2.51 2.53 2.54 2.56 2.58 1 3.13 3.15 3.18 <br /> Tc 22.2 22.5 23.0 23.3 23.0 23.3 23.5 23.8 24.7 24.9 25.1 25.3 1 27.1 27.3 27.5 <br /> 115 SIT 0.87 0.94 0.98 1.00 0.62 0.85 0.94 0.97 0.40 0.58 0.77 0.89 1 0.40 0.55 0.71 <br /> kW 2.63 2.66 2.69 2.69 2.86 2.87 2.89 2.92 2.93 2.95 2.98 3.00 1 3.15 3.16 3.18 <br /> TC 29.9 30.2 30.8 31.2 31.1 31.4 31.7 32.0 33.1 33.4 33.7 33.9 1 37.3 37.6 37.9 <br /> 65 SIT 0.90 0.95 0.98 1.00 0.63 0.86 0.95 1.00 0.39 0.57 0.76 0.97 1 0.39 0.54 0.70 <br /> kW 1.74 1.76 1.77 1.77 1.77 1.79 1.80 1.82 1.82 1.83 1.85 1.87 1 2.24 2.26 2.29 <br /> TC 29.8 30.2 30.8 31.1 30.9 31.2 31.6 31.9 33.0 33.3 33.6 33.8 1 36.9 37.2 37.5 <br /> 75 SIT 0.90 0.95 0.98 1.00 0.63 0.86 0.95 1.00 0.39 0.57 0.76 0.97 1 0.39 0.54 0.70 <br /> kW 2.13 2.15 2.17 2.18 2.17 2.19 2.21 2.22 2.22 2.24 2.26 2.28 1 2.41 2.42 2.43 <br /> TC 29.5 29.8 30.4 30.8 30.6 31.0 31.3 31.6 32.8 33.1 33.4 33.6 1 36.8 37.1 37.3 <br /> 85 SIT 0.90 0.95 0.98 1.00 0.63 0.86 0.95 1.00 0.39 0.57 0.76 0.97 1 0.39 0.54 0.70 <br /> 1020 kW 2.25 2.27 2.29 2.29 2.29 2.31 2.33 2.35 2.35 2.37 2.39 2.41 1 2.67 2.70 2.72 <br /> Tc 29.0 29.3 29.9 30.3 30.1 30.5 30.8 31.1 32.3 32.6 32.B 33.1 1 36.5 36.8 37.0 <br /> 95 SIT 0.90 0.95 0.98 1.00 0.63 0.86 0.95 1.00 0.39 0.57 0.76 0.97 1 0.39 0.54 0.70 <br /> kW 2.54 2.56 2.59 2.60 2.59 2.61 2.64 2.66 2.68 2.69 2.71 2.74 1 3.18 3.19 3.20 <br /> TC 27.6 28.1 28.8 29.1 28.6 28.9 29.3 29.7 30.4 30.8 31.2 31.6 1 35.4 35.5 35.7 <br /> 105 SIT 0.91 0.96 0.99 1.00 0.64 0.87 0.96 1.00 0.40 0.58 0.77 0.98 1 0.40 0.55 0.71 <br /> kW 2.99 3.01 3.03 3.05 3.21 3.22 3.24 3.26 3.43 3.45 3.46 3.47 1 3.67 3.68 3.69 <br /> Tc 22.5 22.9 23.3 23.6 25.1 25.5 25.8 26.0 26.8 27.2 27.4 27.7 1 28.2 28.5 28.7 <br /> 115 SIT 0.92 0.97 1.00 1.00 0.65 0.88 0.97 1.00 0.41 0.59 0.78 0.99 1 0.41 0.56 0.72 <br /> kW 2.65 2.67 2.69 2.71 2.87 2.88 2.90 2.92 3.09 3.11 3.12 3.13 1 3.23 3.25 3.27 <br /> TC 31.3 31.8 32.6 32.9 32.4 32.8 33.2 33.6 34.7 34.9 35.3 35.6 1 41.2 41.5 41.8 <br /> 65 SIT 0.90 0.96 0.99 1.00 0.64 0.87 0.96 1.00 0.39 0.58 0.77 0.98 1 0.39 0.55 0.71 <br /> kW 1.92 1.94 1.96 1.97 1.96 1.98 2.00 2.02 2.07 2.10 2.12 2.14 1 2.47 2.48 2.51 <br /> TC 31.3 31.8 32.4 32.7 32.4 32.8 33.2 33.6 34.5 34.9 35.2 35.5 1 40.9 41.2 41.5 <br /> 75 SIT 0.91 0.96 0.99 1.00 0.64 0.87 0.96 1.00 0.39 0.58 0.77 0.98 1 0.39 0.55 0.71 <br /> kW 2.17 2.19 2.21 2.22 2.21 2.23 2.25 2.27 2.28 2.29 2.32 2.34 1 2.61 2.63 2.64 <br /> TC 30.8 31.2 32.0 32.3 32.0 32.3 32.6 33.0 34.2 34.5 34.9 35.2 1 39.8 40.1 40.4 <br /> 85 SIT 0.91 0.96 0.99 1.00 0.64 0.87 0.96 1.00 0.39 0.58 0.77 0.98 1 0.39 0.55 0.71 <br /> 1150 kW 2.29 2.31 2.34 2.35 2.34 2.37 2.38 2.41 2.52 2.54 2.56 2.58 1 2.97 2.97 2.99 <br /> (High Stage) Tc 30.4 30.9 31.7 32.0 31.9 32.2 32.5 32.9 33.7 34.2 34.6 34.7 1 39.0 39.2 39.4 <br /> 95 SIT 0.91 0.96 0.99 1.00 0.64 0.87 0.96 1.00 0.39 0.58 0.77 0.98 1 0.39 0.55 0.71 <br /> kW 2.70 2.73 2.76 2.77 2.76 2.79 2.81 2.84 2.96 2.98 3.01 3.02 1 3.47 3.48 3.49 <br /> TC 28.9 29.3 29.7 30.0 30.9 31.2 31.5 31.9 32.9 33.3 33.5 33.8 1 36.4 36.7 36.9 <br /> 105 SIT 0.92 0.97 1.00 1.00 0.64 0.88 0.96 1.00 0.40 0.60 0.78 0.99 1 0.40 0.56 0.72 <br /> kW 3.08 3.11 3.12 3.14 3.21 3.25 3.28 3.31 3.43 3.45 3.48 3.50 1 3.73 3.74 3.75 <br /> Tc 23.1 23.5 23.8 24.1 25.4 25.8 26.1 26.4 27.3 27.7 28.0 28.3 1 28.9 29.1 29.2 <br /> 115 SIT 0.93 0.98 1.00 1.00 0.65 0.90 0.98 1.00 0.41 0.64 0.80 1.00 1 0.41 0.57 0.76 <br /> kW 2.71 2.73 2.75 2.77 2.89 2.91 2.93 2.94 3.15 3.17 3.18 3.19 1 3.29 3.30 3.31 <br /> Tc 33.3 33.8 34.6 35.0 34.4 34.9 35.3 35.8 36.7 37.2 37.6 38.0 1 44.0 44.3 44.6 <br /> 65 SIT 0.93 0.98 1.00 1.00 0.66 0.89 0.98 1.00 0.41 0.60 0.79 1.00 1 0.41 0.57 0.73 <br /> kW 2.23 2.25 2.27 2.28 2.27 2.30 2.32 2.34 2.35 2.37 2.39 2.41 1 2.80 2.82 2.85 <br /> Tc 33.2 33.6 34.4 34.7 34.4 34.7 35.1 35.5 36.6 37.1 37.4 37.7 1 43.6 43.8 43.9 <br /> 75 SIT 0.93 0.98 1.00 1.00 0.66 0.89 0.98 1.00 0.41 0.60 0.79 1.00 1 0.41 0.57 0.73 <br /> kW 2.29 2.31 2.34 2.35 2.34 2.35 2.37 2.40 2.41 2.43 2.45 2.48 1 3.07 3.08 3.09 <br /> Tc 32.7 33.2 34.0 34.4 33.8 34.3 34.6 35.1 36.1 36.5 36.9 37.3 1 42.5 42.9 43.3 <br /> 85 SIT 0.93 0.98 1.00 1.00 0.66 0.89 0.98 1.00 0.41 0.60 0.79 1.00 1 0.41 0.57 0.73 <br /> 1350 kW 2.57 2.59 2.62 2.63 2.62 2.65 2.67 2.70 2.72 2.74 2.75 2.77 1 3.28 3.30 3.33 <br /> TC 31.9 32.3 33.1 33.5 32.9 33.4 33.8 34.2 35.2 35.6 35.9 36.4 1 40.4 40.8 41.0 <br /> 95 SIT 0.93 0.98 1.00 1.00 0.66 0.89 0.98 1.00 0.41 0.60 0.79 1.00 1 0.41 0.57 0.73 <br /> kW 3.00 3.03 3.06 3.07 3.06 3.09 3.12 3.15 3.18 3.20 3.21 3.23 1 3.68 3.69 3.70 <br /> Tc 29.4 30.1 30.5 30.8 32.3 32.7 33.0 33.2 34.0 34.4 34.6 34.9 1 36.9 37.4 37.2 <br /> 105 SIT 0.93 0.98 1.00 1.00 0.66 0.90 0.98 1.00 0.41 0.61 0.80 1.00 1 0.41 0.59 0.76 <br /> kW 3.19 3.21 3.23 3.25 3.41 3.42 3.44 3.46 3.63 3.65 3.66 3.67 1 4.06 4.08 4.10 <br /> Tc 23.6 24.1 24.5 24.8 26.3 26.7 27.0 27.2 28.0 28.4 28.6 28.9 1 29.5 29.6 29.7 <br /> 115 SIT 0.95 1.00 1.00 1.00 0.68 0.92 1.00 1.00 0.43 0.66 0.89 1.00 1 0.43 0.65 0.84 <br /> kW 2.75 2.77 2.79 2.81 1 2.93 2.95 2.99 3.02 3.19 3.21 3.22 3.23 3.33 3.35 3.36 <br /> Table 11 <br /> TC refer to total capacity SIT:refer to the ratio of sensible heat and total capacity M refer to total input power <br /> Data subject to change 12.2020 1 Bosch Thermotechnology Corp. <br />