• Bosch IDSBOVI3 18 Product •• • <br /> .r i <br /> Tc 38.7 39.1 40.1 40.5 39.9 40.3 41.0 41.5 42.5 43.0 43.6 43.9 / 50.1 50.5 50.9 <br /> 65 S/T 0.80 0.92 0.94 0.98 0.58 0.76 0.92 0.95 0.39 0.55 0.72 0.90 / 0.39 0.54 0.67 <br /> kW 2.12 2.14 2.16 2.17 2.16 2.18 2.20 2.22 2.23 2.25 2.28 2.29 / 2.88 2.91 2.70 <br /> TC 38.4 38.9 39.8 40.3 39.6 40.1 40.7 41.2 42.2 42.7 43.3 43.7 / 49.6 50.2 50.6 <br /> 75 S/T 0.80 0.92 0.94 0.98 0.58 0.76 0.92 0.95 0.39 0.55 0.72 0.90 / 0.39 0.54 0.67 <br /> kW 2.56 2.58 2.60 2.61 2.60 2.63 2.65 2.66 2.69 2.71 2.74 2.76 / 3.20 3.11 3.13 <br /> Tc 38.0 38.4 39.4 39.8 39.2 39.6 40.2 40.7 42.2 42.5 42.8 43.2 / 49.0 49.4 49.8 <br /> 85 S/T 0.80 0.92 0.94 0.98 0.58 0.76 0.92 0.95 0.39 0.55 0.72 0.90 / 0.39 0.54 0.67 <br /> 1160 kW 2.79 2.82 2.84 2.85 2.84 2.86 2.89 2,90 2.97 2.98 2.98 3.00 / 3.55 3.57 3.60 <br /> TC 37.6 38.0 39.0 39.4 38.8 39.2 39.8 40.4 41.3 41.9 42.4 42.7 / 48.2 48.6 48.9 <br /> 95 S/T 0.80 0.92 0.94 0.98 0.58 0.76 0.92 0.95 0.39 0.55 0.72 0.90 / 0.39 0.54 0.67 <br /> kW 3.26 3.29 3.32 3.33 3.32 3.35 3.38 3.40 3.43 3.46 3.48 3.51 / 4.13 4.16 4.19 <br /> TC 37.2 37.6 38.5 38.9 38.3 38.7 39.4 39.9 40.9 41.3 41.9 42.2 / 47.3 47.6 47.9 <br /> 105 S/T 0.81 0.93 0.96 1.00 0.60 0.77 0.93 0.97 0.39 0.56 0.73 0.91 / 0.39 0.54 0.67 <br /> kW 3.47 3.51 3.52 3.54 3.54 3.57 3.61 3.64 3.66 3.69 3.71 3.74 / 4.48 4.52 4.55 <br /> TC 34.8 35.2 36.1 36.5 36.1 36.5 36.9 37.3 38.7 39.0 39.4 39.6 / 42.9 43.1 43.4 <br /> 115 S/T 0.83 0.95 0.98 1.00 0.62 0.79 0.95 0.99 0.41 0.58 0.75 0.93 / 0.40 0.56 0.69 <br /> kW 4.16 4.20 4.24 4.27 4.27 4.31 4.35 4.39 4.40 4.43 4.48 4.51 / 4.74 4.75 4.75 <br /> TC 40.4 40.8 41.8 42.3 41.6 42.1 42.8 43.2 44.9 45.1 45.5 45.9 / 53.3 53.7 54.2 <br /> 65 S/T 0.82 0.94 0.95 0.98 0.60 0.78 0.93 0.95 0.40 0.57 0.73 0.90 / 0.39 0.55 0.67 <br /> kW 2.28 2.30 2.32 2.33 2.32 2.34 2.36 2.38 2.43 2.44 2.45 2.48 / 2.99 3.02 3.05 <br /> TC 40.6 41.0 42.0 42.5 41.8 42.3 43.0 43.5 44.7 45.2 45.6 46.1 / 53.0 53.4 53.8 <br /> 75 S/T 0.82 0.94 0.95 0.98 0.60 0.78 0.93 0.95 0.40 0.57 0.73 0.90 / 0.39 0.55 0.67 <br /> kW 2.64 2.66 2.69 2.70 2.69 2.71 2.73 2.75 2.77 2.80 2.82 2.85 / 3.41 3.44 3.47 <br /> TC 40.0 40.5 41.5 41.9 41.3 41.7 42.4 42.9 44.1 44.6 45.0 45.5 / 52.1 52.5 52.9 <br /> 85 S/T 0.82 0.94 0.95 0.98 0.60 0.78 0.93 0.95 0.40 0.57 0.73 0.90 / 0.39 0.55 0.67 <br /> 1320 kW 2.98 3.01 3.03 3.04 3.03 3.06 3.09 3.10 3.14 3.16 3.18 3.21 / 3.77 3.80 3.83 <br /> (Low Stage) Tc 39.5 40.0 41.0 41.4 40.8 41.2 41.9 42.4 43.6 44.1 44.4 44.9 / 50.5 50.9 51.3 <br /> 95 S/T 0.82 0.94 0.95 0.98 0.60 0.78 0.93 0.95 0.40 0.57 0.73 0.90 / 0.39 0.55 0.67 <br /> kW 3.47 3.50 3.53 3.54 3.53 3.56 3.59 3.61 3.65 3.68 3.71 3.73 / 4.38 4.41 4.44 <br /> Tc 39.0 39.2 39.5 39.9 40.2 - 40.6 41.2 41.7 43.1 43.5 43.9 44.2 / 48.9 49.3 49.6 <br /> 105 S/T 0.83 0.95 0.97 1.00 0.61 0.79 0.94 0.97 0.41 0.58 0.74 0.91 / 0.39 0.55 0.67 <br /> kW 4.08 4.09 4.13 4.13 4.13 4.17 4.22 4.24 4.25 4.28 4.32 4.34 / 4.77 4.80 4.82 <br /> TC 35.8 36.3 37.1 37.5 37.4 37.7 38.0 38.4 40.1 40.4 40.6 40.5 / 43.3 43.5 43.7 <br /> 115 S/T 0.85 0.97 0.99 1.00 0.63 0.81 0.96 0.99 0.43 0.60 0.76 0.93 / 0.41 0.57 0.69 <br /> kW 4.27 4.31 4.35 4.37 4.40 4.43 4.47 4.50 4.53 4.56 4.59 4.61 / 4.79 4.81 4.83 <br /> Tc 43.0 43.5 44.5 45.0 44.3 44.8 45.5 46.1 47.3 47.9 48.3 48.9 / 54.5 54.9 55.4 <br /> 65 S/T 0.85 0.97 0.98 0.99 0.63 0.81 0.96 0.98 0.43 0.60 0.76 0.93 / 0.39 0.55 0.68 <br /> kW 2.57 2.60 2.62 2.63 2.62 2.64 2.67 2.69 2.70 2.73 2.76 2.79 / 3.23 3.26 3.29 <br /> TC 43.2 43.7 44.7 45.2 44.5 45.0 45.7 46.3 47.6 48.1 48.5 49.0 / 54.1 54.5 54.9 <br /> 75 S/T 0.85 0.97 0.98 0.99 0.63 0.81 0.96 0.98 0.43 0.60 0.76 0.93 / 0.39 0.55 0.68 <br /> kW 2.91 2.94 2.97 2.98 2.97 2.99 3.02 3.04 3.06 3.09 3.12 3.14 / 3.62 3.64 3.67 <br /> Tc 42.5 43.0 44.1 44.6 43.9 44.4 45.0 45.6 46.9 47.5 47.8 48.3 / 53.0 53.5 53.9 <br /> 85 S/T 0.85 0.97 0.98 0.99 0.63 0.81 0.96 0.98 0.43 0.60 0.76 0.93 / 0.39 0.55 0.68 <br /> 1520 kW 3.24 3.27 3.30 3.31 3.30 3.33 3.35 3.37 3.41 3.44 3.46 3.49 / 4.08 4.11 4.13 <br /> TC 42.0 42.5 43.6 44.0 43.4 43.8 44.5 45.1 46.3 46.8 47.4 47.7 / 51.8 52.2 52.6 <br /> 95 SIT 0.85 0.97 0.98 0.99 0.63 0.81 0.96 0.98 0.43 0.60 0.76 0.93 / 0.39 0.55 0.68 <br /> kW 3.58 3.61 3.65 3.65 3.65 3.68 3.72 3.75 3.77 3.79 3.80 3.83 / 4.52 4.56 4.59 <br /> TC 40.2 40.5 41.0 41.3 41.6 42.1 42.5 43.0 44.5 45.0 45.3 45.7 / 49.8 50.1 50.4 <br /> 105 S/T 0.85 0.97 0.98 1.00 0.63 0.81 0.96 0.98 0.43 0.60 0.76 0.93 / 0.40 0.56 0.70 <br /> kW 4.18 4.19 4.22 4.23 4.27 4.31 4.34 4.37 4.38 4.42 4.45 4.48 / 4.85 4.87 4.89 <br /> Tc 36.5 37.1 37.6 38.2 38.6 39.2 39.8 40.5 41.1 41.6 42.0 42.5 / 43.7 43.9 44.1 <br /> 115 S/T 0.89 0.99 1.00 1.00 0.66 0.85 0.98 1.00 0.47 0.64 0.80 0.97 / 0.44 0.60 0.74 <br /> kW 4.39 4.43 4.45 4.47 4.48 4.52 4.59 4.63 4.71 4.74 4.76 4.79 / 4.82 4.84 4.85 <br /> Tc 45.3 45.8 46.8 47.3 46.8 47.3 47.8 48.3 50.2 50.5 50.9 51.6 / 55.3 55.7 56.7 <br /> 65 S/T 0.87 0.99 1.00 1.00 0.65 0.83 0.98 1.00 0.45 0.62 0.78 0.95 / 0.41 0.57 0.71 <br /> kW 2.89 2.92 2.95 2.96 2.95 2.97 3.00 3.03 3.05 3.08 3.10 3.12 / 3.58 3.61 3.59 <br /> TC 45.5 46.0 47.0 47.5 47.0 47.5 48.0 48.6 50.1 50.5 51.1 51.5 / 55.2 55.6 56.0 <br /> 75 S/T 0.87 0.99 1.00 1.00 0.65 0.83 0.98 1.00 0.45 0.62 0.78 0.95 / 0.41 0.57 0.71 <br /> kW 3.09 3.12 3.15 3.16 3.15 3.18 3.21 3.22 3.28 3.31 3.34 3.35 / 3.83 3.85 3.88 <br /> Tc 44.8 45.3 46.4 46.9 46.2 46.7 47.4 48.0 49.4 50.0 50.3 50.8 / 53.7 54.1 54.5 <br /> 85 S/T 0.87 0.99 1.00 1.00 0.65 0.83 0.98 1.00 0.45 0.62 0.78 0.95 / 0.41 0.57 0.71 <br /> 1750 kW 3.52 3.55 3.58 3.59 3.58 3.61 3.64 3.67 3.71 3.74 3.76 3.79 / 4.21 4.25 4.28 <br /> (High Stage) TC 43.9 44.4 45.5 46.0 45.3 45.8 46.5 47.1 48.5 49.0 49.4 49.9 / 52.7 53.1 53.5 <br /> 95 S/T 0.87 0.99 1.00 1.00 0.65 0.83 0.98 1.00 0.45 0.62 0.78 0.95 / 0.41 0.57 0.71 <br /> kW 4.05 4.09 4.13 4.14 4.13 4.16 4.20 4.23 4.28 4.31 4.32 4.35 / 4.90 4.94 4.97 <br /> TC 40.8 41.3 41.7 42.1 42.4 42.8 43.3 43.8 45.4 45.7 46.0 46.4 / 50.8 51.0 51.2 <br /> 105 S/T 0.88 1.00 1.00 1.00 0.66 0.84 0.99 1.00 0.46 0.63 0.79 0.96 / 0.42 0.58 0.72 <br /> kW 4.24 4.26 4.28 4.30 4.33 4.37 4.42 4.44 4.45 4.47 4.50 4.53 / 4.90 4.92 4.95 <br /> TC 37.5 37.9 38.3 38.8 39.4 40.0 40.6 41.3 41.9 42.4 42.8 43.3 / 44.3 44.8 45.0 <br /> 115 S/T 0.91 1.00 1.00 1.00 0.69 0.88 1.00 1.00 0.50 0.67 0.83 1.00 / 0.46 0.62 0.76 <br /> kW 4.46 4.51 4.53 4.54 4.55 4.60 4.65 4.69 4.75 4.77 4.78 4.80 / 4.85 4.87 4.88 <br /> TC 47.7 48.3 49A 50.0 49.2 49.8 50.5 51.2 52.7 53.3 53.6 54.2 / 58.0 58.4 58.8 <br /> 65 S/T 0.90 0.99 1.00 1.00 0.68 0.86 1.00 1.00 0.48 0.65 0.81 0.98 / 0.44 0.60 0.74 <br /> kW 2.94 2.97 3.00 3.00 3.02 3.03 3.05 3.08 3.09 3.12 3.14 3.17 / 3.64 3.67 3.70 <br /> TC 47.3 47.9 49.0 49.6 48.8 49.4 50.1 50.7 52.2 52.8 53.2 53.8 / 57.2 57.6 58.0 <br /> 75 S/T 0.90 0.99 1.00 1.00 0.68 0.86 1.00 1.00 0.48 0.65 0.81 0.98 / 0.44 0.60 0.74 <br /> kW 3.26 3.29 3.32 3.33 3.32 3.35 3.38 3.40 3.44 3.47 3.49 3.52 / 3.93 3.96 3.99 <br /> Tc 46.5 47.0 48.1 48.7 47.9 48.5 49.2 49.8 51.2 51.8 52.2 52.7 / 55.6 56.0 56.4 <br /> 85 S/T 0.90 0.99 1.00 1.00 0.68 0.86 1.00 1.00 0.48 0.65 0.81 0.98 / 0.44 0.60 0.74 <br /> 1880 kW 3.70 3.73 3.77 3.78 3.77 3.80 3.83 3.86 3.90 3.92 3.95 3.98 / 4.43 4.46 4.49 <br /> TC 45.4 45.9 47.1 47.6 46.9 47.4 48.1 48.7 50.2 50.7 51.1 51.6 / 54.0 54.3 54.7 <br /> 95 S/T 0.90 0.99 1.00 1.00 0.68 0.86 1.00 1.00 0.48 0.65 0.81 0.98 / 0.44 0.60 0.74 <br /> kW 4.24 4.28 4.32 4.33 4.32 4.36 4.40 4.43 4.48 4.51 4.53 4.55 / 5.13 5.17 5.20 <br /> TC 41.6 42.1 43.1 43.6 43.6 44.1 44.6 45.1 46.9 47.2 47.6 47.9 / 52.2 52.5 52.8 <br /> 105 S/T 0.91 1.00 1.00 1.00 0.69 0.87 1.00 1.00 0.49 0.66 0.82 0.99 / 0.45 0.61 0.75 <br /> kW 4.33 4.38 4.42 4.42 4.42 4.47 4.52 4.56 4.58 4.61 4.65 4.67 / 4.98 5.00 5.02 <br /> TC 39.5 39.9 40.9 41.4 40.7 41.2 41.8 42.4 43.8 44.2 44.4 44.7 / 44.9 45.1 45.4 <br /> 115 S/T 0.93 1.00 1.00 1.00 0.71 0.91 1.00 1.00 0.51 0.68 0.85 1.00 / 0.47 0.63 0.77 <br /> kW 4.53 4.58 4.63 4.63 4.63 1 4.67 4.72 4.77 4.85 4.86 4.86 4.86 4.88 4.90 4.91 <br /> Table 13 <br /> TC refer to total capacity S/T.refer to the ratio of sensible heat and total capacity M refer to total input power <br /> Data subject to change 12.2020 Bosch Thermotechnology Corp. <br />